Chillers

Read revision 10

Revision 10 · Oct 12, 2026 +83 −18

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 9 to Rev 10 in Chillers.
---
title: Chillers
…140 unchanged lines
- "Dimensional and rigging drawings with tube removal clearance"
- "Coordination drawings with maintenance access"
+constraint: all_of
```
…44 unchanged lines
- "Warranty documentation by serial number"
- "Spare parts inventory by chiller tag and part number"
+constraint: all_of
```
…26 unchanged lines
- "Refrigerant technician certification"
- "Preventive maintenance schedule and published water quality limits"
+constraint: all_of
```
…7 unchanged lines
```datasheet
−label: Minimum Manufacturer Experience
+label: Manufacturer Experience
type: range
unit: years
…3 unchanged lines
setpoints: [0, 3, 5, 10, 15, 20, 25]
default: 10
+constraint: min
```
…3 unchanged lines
```datasheet
−label: Maximum Service Response Time
+label: Service Response Time
type: range
unit: hours
…3 unchanged lines
setpoints: [2, 4, 8, 12, 24, 48, 72]
default: 24
+constraint: max
```
### The manufacturer shall commit in writing that replacement parts for the model furnished will remain available for not less than the period indicated in the datasheet, measured from the date of manufacture.
```datasheet
−label: Minimum Replacement Parts Availability Period
+label: Replacement Parts Availability Period
type: range
unit: years
…3 unchanged lines
setpoints: [5, 10, 15, 20, 25, 30]
default: 15
+constraint: min
```
…15 unchanged lines
- "AHRI certification for water-cooled water-chilling packages"
- "AHRI certification for air-cooled water-chilling packages"
+constraint: all_of
```
…63 unchanged lines
setpoints: [0, 20, 50, 100, 200, 300, 500]
default: 0
+constraint: exact
```
…57 unchanged lines
```datasheet
−label: Maximum Ambient Dry-Bulb Temperature at the Chiller
+label: Highest Ambient Dry-Bulb Temperature at the Chiller
type: range
unit: °F
…4 unchanged lines
setpoints: [80, 90, 95, 100, 105, 110, 115, 120, 130]
default: deferred
+constraint: min
```
```datasheet
−label: Minimum Ambient Dry-Bulb Temperature at the Chiller
+label: Lowest Ambient Dry-Bulb Temperature at the Chiller
type: range
unit: °F
…4 unchanged lines
setpoints: [-40, -20, -10, 0, 10, 20, 32, 40, 50, 60]
default: deferred
+constraint: max
```
```datasheet
−label: Maximum Relative Humidity at the Chiller
+label: Highest Relative Humidity at the Chiller
type: range
unit: '%'
…2 unchanged lines
max: 100
setpoints: [30, 40, 50, 60, 70, 80, 90, 100]
+constraint: min
```
…20 unchanged lines
setpoints: [0, 1000, 2000, 3300, 5000, 6600, 8000, 10000, 12000]
default: deferred
+constraint: exact
```
…52 unchanged lines
setpoints: [0, 10, 20, 25, 30, 35, 40, 50, 60]
default: deferred
+constraint: exact
```
…21 unchanged lines
setpoints: [0, 10, 20, 25, 30, 35, 40, 50, 60]
default: deferred
+constraint: exact
```
…22 unchanged lines
setpoints: [5, 10, 20, 30, 50, 75, 100, 150, 200, 300, 400, 500, 750, 1000, 1250, 1500, 2000, 2500, 3000, 4000, 6000]
default: deferred
+constraint: exact
```
…34 unchanged lines
setpoints: [20, 24, 28, 32, 36, 38, 40, 42, 44, 45, 48, 50, 55, 60]
default: deferred
+constraint: exact
```
…8 unchanged lines
setpoints: [30, 36, 42, 48, 52, 54, 56, 58, 60, 65, 70, 80]
default: deferred
+constraint: exact
```
…8 unchanged lines
setpoints: [5, 20, 50, 100, 200, 300, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 9000, 12000]
default: deferred
+constraint: exact
```
```datasheet
−label: Maximum Evaporator Water-Side Pressure Drop
+label: Evaporator Water-Side Pressure Drop
type: range
unit: ft w.c.
…4 unchanged lines
setpoints: [5, 10, 15, 20, 25, 30, 40, 50, 60]
default: deferred
+constraint: max
```
…44 unchanged lines
setpoints: [45, 55, 60, 65, 70, 75, 78, 80, 82, 85, 90, 95, 100, 105]
default: deferred
+constraint: exact
```
…8 unchanged lines
setpoints: [55, 65, 75, 85, 90, 92, 95, 98, 100, 105, 110, 115, 120]
default: deferred
+constraint: exact
```
…8 unchanged lines
setpoints: [5, 25, 60, 125, 250, 375, 625, 900, 1250, 1875, 2500, 3750, 5000, 7500, 11000, 15000]
default: deferred
+constraint: exact
```
```datasheet
−label: Maximum Condenser Water-Side Pressure Drop
+label: Condenser Water-Side Pressure Drop
type: range
unit: ft w.c.
…4 unchanged lines
setpoints: [5, 10, 15, 20, 25, 30, 40, 50, 60]
default: deferred
+constraint: max
```
…29 unchanged lines
setpoints: [70, 80, 85, 90, 95, 100, 105, 110, 115, 120, 130]
default: deferred
+constraint: exact
```
…10 unchanged lines
setpoints: [50, 60, 65, 70, 72, 74, 76, 78, 80, 82, 85, 90]
default: deferred
+constraint: exact
```
…15 unchanged lines
setpoints: [0, 0.0001, 0.00025, 0.0005, 0.00075, 0.001]
default: 0.0001
+constraint: exact
```
…7 unchanged lines
setpoints: [0, 0.0001, 0.00025, 0.0005, 0.00075, 0.001]
default: 0.00025
+constraint: exact
```
…29 unchanged lines
```datasheet
−label: Maximum Full-Load Power Input
+label: Full-Load Power Input
type: range
unit: kW/ton
…4 unchanged lines
setpoints: [0.25, 0.3, 0.35, 0.4, 0.45, 0.5, 0.55, 0.6, 0.65, 0.7, 0.8, 0.9, 1.0, 1.1, 1.25, 1.4, 1.6, 1.8]
default: deferred
+constraint: max
```
### The part-load power input per unit of capacity at the design conditions shall not exceed the value indicated in the datasheet, computed by the weighting of ANSI/AHRI 550/590.
```datasheet
−label: Maximum Part-Load Power Input
+label: Part-Load Power Input
type: range
unit: kW/ton
…4 unchanged lines
setpoints: [0.15, 0.2, 0.25, 0.3, 0.35, 0.4, 0.45, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.2, 1.5]
default: deferred
+constraint: max
```
…66 unchanged lines
```datasheet
−label: Maximum Refrigerant Global Warming Potential
+label: Refrigerant Global Warming Potential
type: range
options:
min: 0
max: 2100
setpoints: [0, 10, 150, 300, 500, 700, 750, 1500, 2100]
+constraint: max
```
…26 unchanged lines
- "A1"
- "A2L"
+constraint: any_of
```
…20 unchanged lines
- "Service valves isolating the compressor from the circuit"
- "Access ports sized for external recovery equipment"
+constraint: all_of
```
…78 unchanged lines
max: 8
setpoints: [1, 2, 3, 4, 5, 6, 8]
+constraint: exact
```
…7 unchanged lines
max: 6
setpoints: [1, 2, 3, 4, 5, 6]
+constraint: exact
```
…55 unchanged lines
- "Staging of multiple compressors"
- "Hot gas bypass"
+constraint: all_of
```
…8 unchanged lines
max: 60
setpoints: [5, 10, 15, 20, 25, 30, 40, 50, 60]
+constraint: max
```
…83 unchanged lines
```datasheet
−label: Minimum Evaporator Tube Wall Thickness
+label: Evaporator Tube Wall Thickness
type: range
unit: in.
…2 unchanged lines
max: 0.065
setpoints: [0.02, 0.025, 0.028, 0.035, 0.049, 0.065]
+constraint: min
```
…23 unchanged lines
setpoints: [150, 300, 450, 600]
default: 150
+constraint: min
```
…60 unchanged lines
max: 100
setpoints: [20, 25, 30, 40, 50, 60, 70, 80, 100]
+constraint: max
```
…40 unchanged lines
```datasheet
−label: Minimum Cold Surface Insulation Thickness
+label: Cold Surface Insulation Thickness
type: range
unit: in.
…2 unchanged lines
max: 3
setpoints: [0.5, 0.75, 1.0, 1.5, 2.0, 2.5, 3.0]
+constraint: min
```
…47 unchanged lines
```datasheet
−label: Minimum Condenser Tube Wall Thickness
+label: Condenser Tube Wall Thickness
type: range
unit: in.
…2 unchanged lines
max: 0.065
setpoints: [0.02, 0.025, 0.028, 0.035, 0.049, 0.065]
+constraint: min
```
…17 unchanged lines
setpoints: [150, 300, 450, 600]
default: 150
+constraint: min
```
…78 unchanged lines
- "Hail guards"
- "Security screening around the unit base"
+constraint: all_of
```
…68 unchanged lines
setpoints: [208, 230, 240, 380, 460, 480, 575, 600, 2300, 4160, 6900, 13800]
default: deferred
+constraint: exact
```
…65 unchanged lines
setpoints: [5, 10, 14, 18, 22, 25, 30, 35, 42, 50, 65, 85, 100, 150, 200]
default: deferred
+constraint: min
```
…71 unchanged lines
```datasheet
−label: Maximum Total Demand Distortion at the Point of Common Coupling
+label: Total Demand Distortion at the Point of Common Coupling
type: range
unit: '%'
…2 unchanged lines
max: 20
setpoints: [3, 5, 8, 10, 12, 15, 20]
+constraint: max
```
…55 unchanged lines
- "Soft load limiting on a start after an extended shutdown"
- "Automatic restart after a power interruption"
+constraint: all_of
```
### The alarm and event history retained in the controller shall cover not less than the period indicated in the datasheet.
```datasheet
−label: Minimum Retained Alarm and Event History
+label: Retained Alarm and Event History
type: range
unit: days
…3 unchanged lines
setpoints: [7, 14, 30, 60, 90, 180, 365]
default: 30
+constraint: min
```
…37 unchanged lines
- "Excessive compressor starts per hour"
- "Drive fault"
+constraint: all_of
```
…35 unchanged lines
max: 55
setpoints: [20, 26, 32, 36, 38, 40, 42, 44, 46, 50, 55]
+constraint: exact
```
…6 unchanged lines
max: 70
setpoints: [40, 45, 48, 50, 52, 55, 58, 60, 65, 70]
+constraint: exact
```
…99 unchanged lines
- "Compressor run hours and start count"
- "Demand limit setpoint, read and write"
+constraint: all_of
```
…23 unchanged lines
```datasheet
−label: Maximum Sound Power Level at Full Load
+label: Sound Power Level at Full Load
type: range
unit: dB
…4 unchanged lines
setpoints: [60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115]
default: deferred
+constraint: max
```
…17 unchanged lines
- "Condenser fan speed control with a night setback limit"
- "Low-frequency attenuation on the condenser discharge"
+constraint: all_of
```
…72 unchanged lines
```datasheet
−label: Minimum Isolator Static Deflection
+label: Isolator Static Deflection
type: range
unit: in.
…2 unchanged lines
max: 3.5
setpoints: [0.1, 0.25, 0.5, 0.75, 1.0, 1.5, 2.0, 2.5, 3.5]
+constraint: min
```
…52 unchanged lines
- "Factory run test report"
- "Controller point-to-point verification report"
+constraint: all_of
```
…96 unchanged lines
- "Factory-mounted water temperature sensors"
- "Companion flanges or grooved couplings"
+constraint: all_of
```
…87 unchanged lines
- "Verification of every point at the building automation system"
- "Verification of the plant staging sequence"
+constraint: all_of
```
…19 unchanged lines
setpoints: [0, 2, 4, 8, 16, 24, 40]
default: 8
+constraint: min
```
…29 unchanged lines
- "Leak test record with the method and the sensitivity used"
- "Statement of the refrigerant end-use category claimed under 40 CFR Part 84"
+constraint: all_of
```
…75 unchanged lines
setpoints: [1, 2, 3, 5, 7, 10]
default: 1
+constraint: min
```
…8 unchanged lines
max: 10
setpoints: [1, 2, 3, 5, 7, 10]
+constraint: min
```
…31 unchanged lines
- "Refrigerant lost through a warranted failure"
- "Oil replaced during a warranted repair"
+constraint: all_of
```
…51 unchanged lines
- "One set of gaskets for the waterboxes and access covers"
- "One set of pressure and temperature sensors of each type used"
+constraint: all_of
```
…28 unchanged lines
- "Wiring diagrams as built"
- "Spare parts ordering guide with manufacturer part numbers"
+constraint: all_of
```
### The startup report, with the commissioned approaches and operating conditions recorded on it, shall be placed in the operation and maintenance manual.
### That single page answers most future questions about the machine. Every judgment an operator or a service technician later makes about whether a chiller has degraded is a comparison against the day it was known to be right, and without the commissioned baseline the comparison is against a catalog rating taken at conditions the building never sees. {note}