## Action Submittals {toc}
−### The Contractor shall submit the following action submittals for review before fabrication or ordering of hardware: {note}
+### The Contractor shall submit the following action submittals for review before fabrication or ordering of hardware:
- Hardware schedule listing every opening, its assigned hardware set, and each item by manufacturer, product designation, function, finish, and quantity.
- Hardware sets, each numbered and cross-referenced to the openings it serves on the door schedule.
…25 unchanged lines
## Informational Submittals {toc}
−### The Contractor shall submit the following informational submittals: {note}
+### The Contractor shall submit the following informational submittals:
- Certification or qualification of the hardware consultant authoring the sets, where one is engaged.
- Manufacturer listing documentation for fire exit hardware (UL 305 and UL 10C) and panic hardware (UL 305).
…15 unchanged lines
## Closeout Submittals {toc}
−### The Contractor shall submit the following closeout submittals before final acceptance: {note}
+### The Contractor shall submit the following closeout submittals before final acceptance:
- Final keying schedule as keyed, with key bitting record delivered directly to the Owner under separate cover.
- Operation and maintenance manuals for each hardware type, including adjustment and lubrication instructions.
…42 unchanged lines
## All hardware shall be Grade 1 per the applicable ANSI/BHMA A156 standard for commercial and institutional work, including IBC occupancy groups A, B, E, I, M, and R-1.
−## Grade 2 hardware may be used only in light commercial single-tenant office space or residential common areas, and any such downgrade shall be documented in the hardware schedule.
−
−### Specifying Grade 2 locksets or closers to save cost in assembly, educational, or healthcare occupancies produces premature failure under high cycle counts. The savings are recovered as warranty calls and early replacement within the first few years. {note}
−
```datasheet
label: Default hardware grade
…5 unchanged lines
```
+## Grade 2 hardware may be used only in light commercial single-tenant office space or residential common areas, and any such downgrade shall be documented in the hardware schedule.
+
+### Specifying Grade 2 locksets or closers to save cost in assembly, educational, or healthcare occupancies produces premature failure under high cycle counts. The savings are recovered as warranty calls and early replacement within the first few years. {note}
+
+### The party responsible for preparing the hardware sets, a Certified Architectural Hardware Consultant or the architect, shall be specified and documented in the hardware schedule.
+
```datasheet
label: Hardware consultant engaged
…559 unchanged lines
# Spare Parts {toc}
−## The Owner shall be furnished with spare keys and maintenance items so the facility can be operated and serviced after handover. {note}
+## The Owner shall be furnished with spare keys and maintenance items so the facility can be operated and serviced after handover.
## The Contractor shall furnish spare keys in the quantity established by the keying schedule, delivered directly to the Owner.
…13 unchanged lines
- Closer adjustment tools
```