title: Doors, Frames, and Hardware
…221 unchanged lines
### ANSI/SDI A250.8-2023 classifies steel doors by physical performance level (1 through 4) and model (full flush, seamless, stile and rail); performance levels reflect the physical endurance characteristics established by testing under ANSI/SDI A250.4. {note}
+### Level and model selection shall be based on the anticipated use, traffic frequency, and security requirements of each opening, as indicated on the door schedule.
+
```datasheet
label: Hollow Metal Door Performance Level
…19 unchanged lines
```
−### Level and model selection shall be based on the anticipated use, traffic frequency, and security requirements of each opening, as indicated on the door schedule.
−
### The door schedule shall specify the performance level for each opening, and doors shall not default to a single level project-wide without reviewing opening conditions.
…833 unchanged lines
### Electrified hardware includes any door hardware component that requires electrical power to operate or that provides electrical signal output, such as electric strikes (fail-safe or fail-secure), electromagnetic locks (fail-safe), electrified mortise or cylindrical locksets, electrified exit devices, door position switches (contacts), request-to-exit (REX) sensors, and electromagnetic door holders connected to the fire alarm. {note}
+### The electrified hardware components installed at each opening shall be specified, selected from the applicable fail-safe, fail-secure, and signal-output devices required for that opening's function.
+
```datasheet
label: Electrified Hardware at This Opening
…149 unchanged lines
min: 1
max: 15
− setpoints: [5, 10, 15]
+ setpoints: [1, 5, 10, 15]
default: 5
```
…251 unchanged lines
### The following checklist reflects the NFPA 80 (2022 and 2025 editions) annual inspection requirements. {note}
+### All checklist items shall be verified at each fire door assembly at turnover and documented in the closeout submittal.
+
```datasheet
label: Fire Door Assembly — Turnover Inspection Checklist
…16 unchanged lines
```
−### All checklist items shall be verified at each fire door assembly at turnover and documented in the closeout submittal.
−
### Any deficiency discovered shall be corrected and the assembly re-inspected before turnover documentation is issued.
…18 unchanged lines
# Warranty {toc}
−## Hollow Metal Doors and Frames {toc}
+## Hollow Metal Door and Frame Warranty {toc}
```datasheet
…60 unchanged lines
### Deficiencies discovered during the warranty period that are attributable to installation workmanship shall be corrected by the Contractor at no cost to the Owner.