Fluid-Applied Waterproofing

Read revision 7

Revision 7 · Oct 12, 2026 +40 −9

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 6 to Rev 7 in Fluid-Applied Waterproofing.
---
title: Fluid-Applied Waterproofing
…110 unchanged lines
- "Integrity test and inspection plan"
- "Sample warranty forms"
+constraint: all_of
```
…38 unchanged lines
- "As-installed drawings"
- "Maintenance data"
+constraint: all_of
```
…7 unchanged lines
```datasheet
−label: Minimum Comparable Projects Completed by the Applicator
+label: Comparable Projects Completed by the Applicator
type: range
unit: projects
…2 unchanged lines
max: 10
setpoints: [0, 1, 3, 5, 10]
+constraint: min
```
…41 unchanged lines
max: 400
setpoints: [25, 50, 100, 200, 400]
+constraint: min
```
…19 unchanged lines
- "Pipe penetration"
- "Vertical termination"
+constraint: all_of
```
…173 unchanged lines
max: 250
setpoints: [40, 60, 80, 90, 100, 120, 150, 180, 215, 250]
+constraint: min
```
…12 unchanged lines
max: 120
setpoints: [30, 40, 50, 60, 75, 90, 100, 120]
+constraint: min
```
…13 unchanged lines
setpoints: [90, 125, 180, 215, 250]
default: 215
+constraint: min
```
…101 unchanged lines
max: 0.25
setpoints: [0.0625, 0.125, 0.25]
+constraint: exact
```
…74 unchanged lines
```datasheet
−label: Minimum Concrete Age Before Membrane
+label: Concrete Age Before Membrane
type: range
unit: days
…2 unchanged lines
max: 28
setpoints: [3, 5, 7, 14, 21, 28]
+constraint: min
```
…12 unchanged lines
- "Anhydrous calcium chloride to ASTM F1869"
- "Electronic moisture meter per the membrane manufacturer's procedure"
+constraint: any_of
```
### Where the in situ relative humidity probe is selected, the substrate relative humidity shall not exceed the value indicated in the datasheet at the time of application.
```datasheet
−label: Maximum Substrate Relative Humidity (ASTM F2170)
+label: Substrate Relative Humidity (ASTM F2170)
type: range
unit: '%'
…2 unchanged lines
max: 100
setpoints: [75, 80, 85, 90, 95, 100]
+constraint: max
```
…13 unchanged lines
```datasheet
−label: Minimum Concrete Surface Profile (ICRI 310.2R CSP)
+label: Concrete Surface Profile, Low End (ICRI 310.2R CSP)
type: range
unit: CSP
…3 unchanged lines
setpoints: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10]
default: 3
+constraint: min
```
### The prepared concrete shall present a surface profile not greater than the maximum indicated in the datasheet.
```datasheet
−label: Maximum Concrete Surface Profile (ICRI 310.2R CSP)
+label: Concrete Surface Profile, High End (ICRI 310.2R CSP)
type: range
unit: CSP
…2 unchanged lines
max: 10
setpoints: [1, 2, 3, 4, 5, 6, 7, 8, 9, 10]
+constraint: max
```
…19 unchanged lines
- "Steel shot blasting"
- "Diamond grinding"
+constraint: any_of
```
…40 unchanged lines
setpoints: [0.016, 0.031, 0.0625, 0.125]
default: 0.0625
+constraint: exact
```
…30 unchanged lines
```datasheet
−label: Minimum Air and Substrate Temperature at Application
+label: Air and Substrate Temperature at Application
type: range
unit: °F
…2 unchanged lines
max: 50
setpoints: [0, 20, 25, 32, 40, 45, 50]
+constraint: min
```
…7 unchanged lines
```datasheet
−label: Minimum Substrate Temperature Margin Above Dew Point
+label: Substrate Temperature Margin Above Dew Point
type: range
unit: °F
…3 unchanged lines
setpoints: [3, 5, 10]
default: 5
+constraint: min
```
…40 unchanged lines
setpoints: [2, 4, 6, 8, 10, 12]
default: deferred
+constraint: min
```
…109 unchanged lines
- "Afterburner-equipped kettle"
- "Low-fume asphalt formulation"
+constraint: all_of
```
…23 unchanged lines
- "Wet-film gauge readings recorded during application"
- "Material consumption reconciled against the area covered"
+constraint: all_of
```
…8 unchanged lines
max: 10
setpoints: [1, 2, 4, 5, 10]
+constraint: min
```
…15 unchanged lines
default:
- "Flood test to ASTM D5957"
+constraint: all_of
```
…11 unchanged lines
setpoints: [1, 2, 3, 4]
default: 2
+constraint: exact
```
…9 unchanged lines
setpoints: [24, 48, 72]
default: 24
+constraint: min
```
…23 unchanged lines
- "Vertical areas"
- "Areas over repaired substrate"
+constraint: all_of
```
…8 unchanged lines
max: 10000
setpoints: [500, 1000, 2500, 5000, 10000]
+constraint: max
```
### Where adhesion testing is selected, the tensile bond shall be not less than the value indicated in the datasheet.
```datasheet
−label: Minimum Pull-Off Adhesion
+label: Pull-Off Adhesion
type: range
unit: psi
…2 unchanged lines
max: 400
setpoints: [50, 100, 150, 200, 250, 300, 400]
+constraint: min
```
…27 unchanged lines
```datasheet
−label: Maximum Exposure of a Buried Membrane Before Protection
+label: Exposure of a Buried Membrane Before Protection
type: range
unit: days
…2 unchanged lines
max: 30
setpoints: [0, 1, 3, 7, 14, 30]
+constraint: max
```
…60 unchanged lines
max: 30
setpoints: [0, 5, 10, 15, 20, 25, 30]
+constraint: min
```
…13 unchanged lines
setpoints: [1, 2, 3, 5]
default: 2
+constraint: min
```
…21 unchanged lines
## A blocked drain turns a free-draining deck into a membrane under sustained head, and it is the most common cause of distress in an otherwise sound installation. {note}