Lighting Controls

Read revision 6

Revision 6 · Oct 12, 2026 +27 −2

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 5 to Rev 6 in Lighting Controls.
---
title: Lighting Controls
…103 unchanged lines
- "UL 924 override device documentation"
- "Functional test plan"
+constraint: all_of
```
…22 unchanged lines
- "Installer and programmer qualification statements"
- "Software support policy"
+constraint: all_of
```
…28 unchanged lines
- "Training record"
- "Warranty documentation"
+constraint: all_of
```
…54 unchanged lines
```datasheet
−label: Minimum Installer Comparable Projects
+label: Installer Comparable Projects
type: range
unit: projects
…3 unchanged lines
setpoints: [0, 1, 3, 5, 10]
default: 3
+constraint: min
```
…127 unchanged lines
```datasheet
−label: Minimum Wireless Device Battery Life
+label: Wireless Device Battery Life
type: range
unit: years
…2 unchanged lines
max: 15
setpoints: [2, 3, 5, 7, 10, 15]
+constraint: min
```
…87 unchanged lines
setpoints: [0.1, 1, 5, 10]
default: 10
+constraint: max
```
…58 unchanged lines
setpoints: [20, 30, 40, 50, 60, 75]
default: 50
+constraint: exact
```
…34 unchanged lines
max: 30
setpoints: [1, 5, 10, 15, 20, 30]
+constraint: exact
```
…98 unchanged lines
setpoints: [5, 10, 20, 30, 40, 50, 75, 100]
default: derived
+constraint: exact
```
…34 unchanged lines
setpoints: [24, 72, 168, 240]
default: 72
+constraint: min
```
…14 unchanged lines
max: 4
setpoints: [0.25, 0.5, 1, 2, 4]
+constraint: exact
```
…30 unchanged lines
setpoints: [1, 2, 5, 10, 15]
default: 5
+constraint: min
```
…94 unchanged lines
setpoints: [15, 20, 30, 60, 100]
default: derived
+constraint: min
```
…31 unchanged lines
setpoints: [0, 10, 20, 25, 50]
default: 20
+constraint: min
```
…84 unchanged lines
setpoints: [10, 15, 20, 25, 30, 40, 50]
default: derived
+constraint: exact
```
…73 unchanged lines
- "Room scheduling system, occupied periods"
- "Space analytics, occupancy and count data export"
+constraint: all_of
```
…28 unchanged lines
setpoints: [1, 3, 12, 24, 36, 60]
default: 12
+constraint: min
```
…177 unchanged lines
setpoints: [50, 60, 70, 80, 85, 90, 100]
default: 100
+constraint: exact
```
…52 unchanged lines
- "Emergency override to full output, switched off and dimmed"
- "Final programmed settings by zone"
+constraint: all_of
```
…33 unchanged lines
max: 12
setpoints: [0, 1, 3, 6, 12]
+constraint: exact
```
…10 unchanged lines
max: 24
setpoints: [0, 2, 4, 8, 16, 24]
+constraint: min
```
…26 unchanged lines
max: 10
setpoints: [1, 2, 3, 5, 10]
+constraint: min
```
…8 unchanged lines
max: 10
setpoints: [1, 2, 3, 5, 10]
+constraint: min
```
…18 unchanged lines
max: 25
setpoints: [0, 2, 5, 10, 25]
+constraint: min
```
…13 unchanged lines
- "UL 924 override devices, each type"
- "Batteries for wireless devices, one replacement set"
+constraint: all_of
```
…3 unchanged lines
## Spare devices shall be delivered with the software, the licenses, and the addressing instructions needed to put them into service in the installed system without the manufacturer's attendance.

View current revision