Metal Lockers
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 5
to Rev 6
in Metal Lockers.
---
title: Metal Lockers
…90 unchanged lines
- "Finish color samples, full standard color line"
- "Finish test reports (D3359, B117, D2794, D523)"
+constraint: all_of
```
…32 unchanged lines
- "Lock control record (keying schedule, combination list, programming record)"
- "Attic stock inventory"
+constraint: all_of
```
…232 unchanged lines
setpoints: [9, 12, 15, 18, 24, 30, 36]
default: deferred
+constraint: exact
```
…9 unchanged lines
setpoints: [9, 12, 15, 18, 21, 24]
default: deferred
+constraint: exact
```
…9 unchanged lines
setpoints: [36, 42, 48, 60, 66, 72, 78]
default: deferred
+constraint: exact
```
…71 unchanged lines
max: 3
setpoints: [1, 2, 3]
+constraint: min
```
…187 unchanged lines
```datasheet
−label: Minimum Salt-Spray Exposure, ASTM B117
+label: Salt-Spray Exposure, ASTM B117
type: range
unit: h
…2 unchanged lines
setpoints: [96, 250, 500, 750, 1000]
default: 500
+constraint: min
```
…78 unchanged lines
- "Finished end panels at exposed locker ends"
- "Filler panels at walls, columns, and obstructions"
+constraint: all_of
```
…27 unchanged lines
- "Double-prong ceiling hooks"
- "Top shelf"
+constraint: all_of
```
…75 unchanged lines
step: 1
default: 5
+constraint: min
```
…123 unchanged lines
max: 1.5
setpoints: [1.0, 1.5]
+constraint: min
```
…33 unchanged lines
max: 25
setpoints: [1, 2, 3, 5, 10, 15, 25]
+constraint: min
```
…14 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…28 unchanged lines
- "Spare locks of each installed type"
- "Touch-up coating of each installed color"
+constraint: all_of
```
…7 unchanged lines
max: 10
step: 1
+constraint: exact
```
## Attic stock shall be delivered in labeled cartons identifying the component, the finish color, and the locker type it fits.
## Attic stock shall be delivered to the location the Owner designates and shall be receipted by the Owner's representative.