−Cleanroom−Concrete−Flooring−Food Processing−Healthcare−Industrial−Laboratory
---
title: Resinous Flooring
…196 unchanged lines
label: Maximum Slab Internal Relative Humidity (ASTM F2170)
type: range
−unit: % RH
+unit: '% RH'
options:
min: 75
…512 unchanged lines
## The Contractor shall deliver to the Owner a sealed manufacturer touch-up or repair kit for each resinous system and color installed, sufficient to repair localized damage, labeled with the system, color, and batch information, and stored in the conditioned environment the manufacturer recommends.
## Because a resinous floor is mixed and cured on site, a later repair made with off-the-shelf material will rarely match the color and gloss of the original; a repair kit from the original system and color is the only practical way to make an inconspicuous repair, and resin shelf life means the kit should be used within the manufacturer's stated storage period. {note}