title: Sheet Metal Flashing and Trim
…370 unchanged lines
label: Prefinished Coil Color Selection
type: text
−drawing_ref: true
−default: "Per Designer of Record — see finish schedule on drawings"
+drawing_ref: "finish schedule"
+default: deferred
```
…379 unchanged lines
label: Gutter Cross-Section Sizing Basis
type: text
−drawing_ref: true
−default: "Per Designer of Record roof drainage calculation — see civil and roof drawings"
+drawing_ref: "civil and roof drawings"
+default: deferred
```
…132 unchanged lines
label: Design Movement at Wall Expansion Joint
type: text
−drawing_ref: true
−default: "Per Structural Engineer of Record — see structural drawings"
+drawing_ref: "structural drawings"
+default: deferred
```
…147 unchanged lines
## Coil-coated panels stored flat with weight on top: panels shall be stored on edge or otherwise unloaded during storage, because stacking pressure causes oil-canning, finish indentation, and edge damage along contact lines.
## Coping cleat fastener pattern not matching ES-1 listing: the Contractor shall verify the as-installed cleat fastener pattern against the listing documentation in the submittal before closing in the work, because substituting fastener type, spacing, or substrate from the ES-1-listed assembly voids the listing.