Structural Steel Connections
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 6
to Rev 7
in Structural Steel Connections.
---
title: Structural Steel Connections
…93 unchanged lines
- "Pre-installation verification plan"
- "Bolting inspection plan"
+constraint: all_of
```
…29 unchanged lines
- "Nonconformance log"
- "Certificates of compliance"
+constraint: all_of
```
…244 unchanged lines
setpoints: [0.5, 0.625, 0.75, 0.875, 1, 1.125, 1.25, 1.5]
default: deferred
+constraint: exact
```
…110 unchanged lines
- "Twist-off tension-control bolt"
- "Direct tension indicator"
+constraint: any_of
```
…110 unchanged lines
default:
- "Standard holes"
+constraint: any_of
```
…217 unchanged lines
max: 100
setpoints: [0, 10, 25, 50, 100]
+constraint: min
```
…45 unchanged lines
## A connection found defective within the warranty period shall be corrected by the responsible party at its own expense, including disassembly, new fastener assemblies, re-welding, re-inspection, and restoration of the coating system disturbed by the correction.