label: Maximum Slab Internal Relative Humidity (ASTM F2170)
type: range
−unit: % RH
+unit: '% RH'
options:
min: 80
…196 unchanged lines
label: Maximum Matrix Water Absorption (ASTM C413)
type: range
−unit: %
+unit: '%'
options:
min: 0.1
…389 unchanged lines
label: Attic Stock Quantity
type: range
−unit: % of installed area
+unit: '% of installed area'
options:
min: 1
…6 unchanged lines
## Spare material shall be stored by the Owner in the conditioned environment the manufacturer recommends.
## Because terrazzo is repaired by grinding out and re-pouring a patch with matching matrix and aggregate, attic stock of the original materials allows a future repair to be blended into the floor; a later-purchased replacement aggregate from a different batch will not match the surrounding field. {note}