title: Unit Masonry
…230 unchanged lines
- "10 × 8 × 16 in"
- "12 × 8 × 16 in"
− - "As indicated on drawings"
drawing_ref: true
default: "8 × 8 × 16 in"
…20 unchanged lines
- "2,500 psi"
- "3,000 psi"
− - "As indicated on structural drawings"
default: "1,900 psi (ASTM C90 minimum)"
```
…246 unchanged lines
- "2,500 psi"
- "3,000 psi"
− - "As indicated on structural drawings"
default: "2,000 psi (TMS 602 minimum)"
```
…75 unchanged lines
- "16 in. o.c. (every other course)"
- "24 in. o.c."
− - "As indicated on structural drawings"
default: "16 in. o.c. (every other course)"
```
…42 unchanged lines
label: Vertical Reinforcement Bar Sizes
type: text
−drawing_ref: true
−default: "As indicated on structural drawings"
+drawing_ref: "structural drawings"
+default: deferred
```
…102 unchanged lines
- "Stainless steel sheet (long-term, maintenance-free, premium)"
- "Copper sheet (premium, historic masonry)"
− - "As specified on drawings"
drawing_ref: true
default: "Rubberized asphalt membrane — self-adhesive, flexible, compatible with most substrates"
…264 unchanged lines
- "Face-shell bedding (standard for hollow CMU)"
- "Full mortar bedding (first course, bond beams, top of wall, concentrated loads)"
− - "As indicated on structural drawings"
−drawing_ref: true
+drawing_ref: "structural drawings"
default: "Face-shell bedding (standard for hollow CMU)"
```
…111 unchanged lines
- "2,500 psi"
- "3,000 psi"
− - "As indicated on structural drawings"
default: "2,000 psi"
```
…220 unchanged lines
## The warranty for areas accepted at reduced f'm is limited to workmanship and installation quality and does not independently warrant structural performance, which is an engineering determination made by the Engineer of Record. {note}