Window Treatments

Read revision 8

Revision 8 · Oct 12, 2026 +35 −8

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 7 to Rev 8 in Window Treatments.
---
title: Window Treatments
…113 unchanged lines
- "Shop drawings of opening conditions and details"
- "Fire performance reports"
+constraint: all_of
```
…22 unchanged lines
- "Fabric qualification on the selected hardware"
- "Field measurement record"
+constraint: all_of
```
…21 unchanged lines
- "Operation and maintenance data"
- "Warranty documentation"
+constraint: all_of
```
…45 unchanged lines
```datasheet
−label: Minimum Comparable Projects Completed by the Installer
+label: Comparable Projects Completed by the Installer
type: range
unit: projects
…2 unchanged lines
max: 10
setpoints: [0, 1, 2, 3, 5, 10]
+constraint: min
```
…12 unchanged lines
- "One motorized control zone commissioned and demonstrated"
- "One drapery at a representative opening"
+constraint: all_of
```
…61 unchanged lines
- "Dual-roller shades"
- "Draperies on track"
+constraint: all_of
```
…10 unchanged lines
default:
- "Manual operation"
+constraint: all_of
```
…54 unchanged lines
setpoints: [1, 2, 3, 4, 5, 7, 10, 14]
default: deferred
+constraint: exact
```
…9 unchanged lines
```datasheet
−label: Minimum Solar Reflectance of the Exterior-Facing Face
+label: Solar Reflectance of the Exterior-Facing Face
type: range
unit: '%'
…3 unchanged lines
max: 80
setpoints: [5, 10, 20, 30, 40, 50, 60, 70, 80]
+constraint: min
```
### The maximum visible transmittance of the fabric shall be as indicated in the datasheet.
```datasheet
−label: Maximum Visible Transmittance
+label: Visible Transmittance
type: range
unit: '%'
…3 unchanged lines
max: 40
setpoints: [1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40]
+constraint: max
```
### The maximum solar transmittance of the fabric shall be as indicated in the datasheet.
```datasheet
−label: Maximum Solar Transmittance
+label: Solar Transmittance
type: range
unit: '%'
…3 unchanged lines
max: 40
setpoints: [1, 2, 3, 5, 7, 10, 15, 20, 25, 30, 40]
+constraint: max
```
…26 unchanged lines
```datasheet
−label: Maximum Visible Transmittance of Room-Darkening Fabric
+label: Visible Transmittance of Room-Darkening Fabric
type: range
unit: '%'
…2 unchanged lines
max: 10
setpoints: [0.5, 1, 2, 3, 5, 10]
+constraint: max
```
…71 unchanged lines
```datasheet
−label: Minimum Lightfastness Exposure at Gray Scale Rating 4
+label: Lightfastness Exposure at Gray Scale Rating 4
type: range
unit: hours
…2 unchanged lines
max: 500
setpoints: [20, 40, 60, 80, 100, 200, 300, 500]
+constraint: min
```
…11 unchanged lines
- "Mildew resistance demonstrated under AATCC TM30"
- "Antimicrobial activity demonstrated under ASTM E2180"
+constraint: all_of
```
…29 unchanged lines
setpoints: [1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4]
default: derived
+constraint: exact
```
…253 unchanged lines
```datasheet
−label: Maximum Motor Sound Level at 3 ft
+label: Motor Sound Level at 3 ft
type: range
unit: dBA
…2 unchanged lines
max: 55
setpoints: [30, 35, 38, 40, 42, 44, 46, 48, 50, 55]
+constraint: max
```
…45 unchanged lines
default:
- "Wall-mounted control stations"
+constraint: all_of
```
…120 unchanged lines
max: 3
setpoints: [1, 1.2, 1.5, 1.8, 2, 2.5, 3]
+constraint: exact
```
…45 unchanged lines
```datasheet
−label: Maximum Light Gap per Side at Inside Mounts
+label: Light Gap per Side at Inside Mounts
type: range
unit: in.
…2 unchanged lines
max: 1
setpoints: [0.25, 0.375, 0.5, 0.625, 0.75, 1]
+constraint: max
```
…17 unchanged lines
max: 6
setpoints: [0.5, 1, 1.5, 2, 3, 4, 6]
+constraint: exact
```
…72 unchanged lines
- "Upper and lower limits set at every motorized shade"
- "Level deployment of every control zone"
+constraint: all_of
```
…86 unchanged lines
max: 25
setpoints: [1, 2, 3, 5, 10, 25]
+constraint: min
```
…8 unchanged lines
max: 25
setpoints: [1, 2, 3, 5, 10, 25]
+constraint: min
```
…11 unchanged lines
setpoints: [1, 2, 3, 5, 7, 10]
default: 5
+constraint: min
```
…9 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…18 unchanged lines
max: 10
setpoints: [0, 1, 2, 3, 5, 10]
+constraint: min
```
…12 unchanged lines
- "Spare wall control stations and handheld transmitters"
- "Configuration software, programming tool, and credentials"
+constraint: all_of
```
## Spare parts shall be the same make and model as the installed items and shall be delivered in their original unopened packaging, labeled with the shade type and the opening marks they serve.
## Where the motorized system is configured through software, the credentials and the configuration file required to reprogram every motor and control device shall be turned over to the Owner with the spare parts.

View current revision