Aluminum Entrances and Storefronts
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 9
to Rev 10
in Aluminum Entrances and Storefronts.
---
title: Aluminum Entrances and Storefronts
…134 unchanged lines
- "Mock-up test report"
default: ["Storefront shop drawing elevations", "Storefront shop drawing section details", "Door elevations by type", "Hardware schedule by hardware set", "Signed and sealed structural calculations", "Framing, door, gasket, and sealant product data", "Insulating glass unit make-up submittal", "NFRC thermal and optical performance reports", "Finish samples on the furnished profile"]
+constraint: all_of
```
…19 unchanged lines
- "Manufacturer written installation instructions"
default: ["Manufacturer qualification statement with test reports", "Installer qualification statement with references", "Insulating glass unit fabricator certification", "Manufacturer written installation instructions"]
+constraint: all_of
```
…23 unchanged lines
- "Spare parts inventory receipt"
default: ["As-built elevations and schedules", "Field test reports including retests", "Door closer adjustment record", "Cleaning and maintenance instructions", "Framing manufacturer warranty", "Insulating glass unit warranty", "Finish warranty", "Sealant warranty", "Hardware warranty", "Spare parts inventory receipt"]
+constraint: all_of
```
…9 unchanged lines
```datasheet
−label: Installer Minimum Years of Experience with Comparable Systems
+label: Installer Years of Experience with Comparable Systems
type: range
unit: years
min: 0
max: 10
setpoints: [0, 2, 3, 5, 10]
+constraint: min
```
…66 unchanged lines
drawing_ref: "structural drawings"
default: deferred
+constraint: min
```
…9 unchanged lines
drawing_ref: "structural drawings"
default: deferred
+constraint: min
```
…37 unchanged lines
setpoints: [0.125, 0.25, 0.375, 0.5, 0.75, 1, 1.5]
default: 0.75
+constraint: max
```
…13 unchanged lines
max: 6.24
setpoints: [1.57, 2.86, 6.24]
+constraint: min
```
…8 unchanged lines
setpoints: [0.01, 0.03, 0.06, 0.1, 0.2, 0.3]
default: 0.06
+constraint: max
```
…8 unchanged lines
setpoints: [0.3, 0.5, 0.75, 1, 1.5]
default: 1
+constraint: max
```
…11 unchanged lines
max: 20
setpoints: [2.86, 5, 6.24, 8, 10, 12, 15, 20]
+constraint: min
```
…19 unchanged lines
```datasheet
−label: Maximum Whole-Product U-Factor
+label: Whole-Product U-Factor
type: range
unit: Btu/h·ft²·°F
…3 unchanged lines
drawing_ref: "energy compliance documentation"
default: deferred
+constraint: max
```
## The maximum whole-product solar heat gain coefficient shall be as indicated in the datasheet.
```datasheet
−label: Maximum Whole-Product Solar Heat Gain Coefficient
+label: Whole-Product Solar Heat Gain Coefficient
type: range
unit: SHGC
…3 unchanged lines
drawing_ref: "energy compliance documentation"
default: deferred
+constraint: max
```
## The minimum whole-product visible transmittance shall be as indicated in the datasheet.
```datasheet
−label: Minimum Whole-Product Visible Transmittance
+label: Whole-Product Visible Transmittance
type: range
unit: VT
…3 unchanged lines
drawing_ref: "energy compliance documentation"
default: deferred
+constraint: min
```
…19 unchanged lines
```datasheet
−label: Minimum Condensation Rating
+label: Condensation Rating
type: range
unit: rating
…3 unchanged lines
drawing_ref: "energy compliance documentation"
default: deferred
+constraint: min
```
…11 unchanged lines
```datasheet
−label: Minimum Sound Transmission Class
+label: Sound Transmission Class
type: range
unit: STC
…3 unchanged lines
drawing_ref: "acoustic requirements on the contract documents"
default: deferred
+constraint: min
```
## The minimum outdoor-indoor transmission class, rated in accordance with ASTM E1332, shall be as indicated in the datasheet.
```datasheet
−label: Minimum Outdoor-Indoor Transmission Class
+label: Outdoor-Indoor Transmission Class
type: range
unit: OITC
…3 unchanged lines
drawing_ref: "acoustic requirements on the contract documents"
default: deferred
+constraint: min
```
…57 unchanged lines
drawing_ref: "structural drawings"
default: deferred
+constraint: min
```
…38 unchanged lines
```datasheet
−label: Minimum Wall Thickness — Structural Members
+label: Wall Thickness — Structural Members
type: range
unit: in.
…2 unchanged lines
setpoints: [0.05, 0.062, 0.07, 0.08, 0.093, 0.109, 0.125, 0.156, 0.188]
default: 0.08
+constraint: min
```
## The minimum wall thickness of non-structural glass stops, pressure plates, and trim shall be as indicated in the datasheet.
```datasheet
−label: Minimum Wall Thickness — Non-Structural Members
+label: Wall Thickness — Non-Structural Members
type: range
unit: in.
…2 unchanged lines
setpoints: [0.04, 0.05, 0.062, 0.07, 0.08, 0.093, 0.125]
default: 0.062
+constraint: min
```
…26 unchanged lines
max: 60
setpoints: [6, 10, 14, 16, 20, 24, 28, 32, 36, 40, 50, 60]
+constraint: exact
```
…23 unchanged lines
drawing_ref: "storefront section details"
default: deferred
+constraint: exact
```
…9 unchanged lines
drawing_ref: "storefront elevations"
default: deferred
+constraint: exact
```
…110 unchanged lines
drawing_ref: "glazing schedule"
default: deferred
+constraint: exact
```
…34 unchanged lines
drawing_ref: "glazing schedule"
default: deferred
+constraint: exact
```
…46 unchanged lines
max: 120
setpoints: [15, 30, 45, 60, 90, 120]
+constraint: exact
```
…60 unchanged lines
setpoints: [0.25, 0.3125, 0.375, 0.5, 0.625, 0.75, 1]
default: 0.5
+constraint: exact
```
…123 unchanged lines
setpoints: [50, 60, 70, 80, 85, 90, 95]
default: 85
+constraint: exact
```
…47 unchanged lines
max: 100
setpoints: [12.5, 25, 35, 50, 100]
+constraint: min
```
…38 unchanged lines
drawing_ref: "door schedule"
default: deferred
+constraint: exact
```
…9 unchanged lines
drawing_ref: "door schedule"
default: deferred
+constraint: exact
```
…63 unchanged lines
drawing_ref: "door schedule"
default: deferred
+constraint: exact
```
…3 unchanged lines
```datasheet
−label: Maximum Door Opening Force
+label: Door Opening Force
type: range
unit: lbf
min: 3
max: 30
setpoints: [3, 5, 8.5, 15, 30]
+constraint: max
```
…5 unchanged lines
```datasheet
−label: Maximum Threshold Height
+label: Threshold Height
type: range
unit: in.
…2 unchanged lines
setpoints: [0, 0.25, 0.375, 0.5, 0.75]
default: 0.5
+constraint: max
```
…71 unchanged lines
- "Adjustable spring power"
default: ["Adjustable closing speed", "Adjustable latch speed", "Back-check"]
+constraint: all_of
```
…307 unchanged lines
drawing_ref: "structural drawings"
default: deferred
+constraint: min
```
…99 unchanged lines
setpoints: [0.0625, 0.125, 0.1875, 0.25, 0.375, 0.5]
default: 0.25
+constraint: max
```
…75 unchanged lines
- "Sound transmission loss per ASTM E90"
default: ["Air infiltration per ASTM E283", "Static water penetration per ASTM E331", "Structural performance per ASTM E330"]
+constraint: all_of
```
…10 unchanged lines
- "Newly installed storefront system test per AAMA 503"
default: ["Diagnostic water spray check per AAMA 501.2"]
+constraint: all_of
```
…9 unchanged lines
drawing_ref: "field test plan"
default: deferred
+constraint: min
```
…54 unchanged lines
setpoints: [1, 2, 3, 5, 10]
default: 2
+constraint: min
```
…8 unchanged lines
setpoints: [5, 10, 15, 20]
default: 10
+constraint: min
```
…7 unchanged lines
max: 30
setpoints: [5, 10, 15, 20, 25, 30]
+constraint: min
```
…8 unchanged lines
setpoints: [5, 10, 15, 20]
default: 10
+constraint: min
```
…8 unchanged lines
setpoints: [1, 2, 3, 5, 10]
default: 2
+constraint: min
```
…34 unchanged lines
- "Touch-up coating in each furnished color"
default: ["Glazing gasket stock by profile", "Door perimeter weatherseal stock by profile", "Door closer adjustment tools", "Touch-up coating in each furnished color"]
+constraint: all_of
```
…8 unchanged lines
setpoints: [0, 1, 2, 3, 5, 10]
default: 2
+constraint: min
```
## Spare gaskets, seals, and setting blocks shall be from the same production lot as the installed material where the material is lot-sensitive, and shall be labeled with the profile designation, the lot, and the date of manufacture.
## Spare material stored beyond the shelf life published by its manufacturer is not usable for its intended repair, so the labeling is what lets the Owner know when the stock must be replaced rather than relied on. {note}