Building Thermal Insulation
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 10
to Rev 11
in Building Thermal Insulation.
---
title: Building Thermal Insulation
…133 unchanged lines
- "Product samples where the insulation or its facing remains visible"
default: "Product data and physical properties for each insulation product"
+constraint: all_of
```
…26 unchanged lines
- "Manufacturer warranty documents"
default: "Signed certificate of conformance"
+constraint: all_of
```
…185 unchanged lines
setpoints: [0, 10, 13, 15, 20, 25, 30, 33, 38, 45, 49, 55, 60, 70, 80, 90, 100]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 5, 7.5, 10, 13, 15, 18, 20, 23, 25, 28, 30, 35, 40, 50, 60]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 2.5, 3.8, 5, 6, 7.5, 10, 11.4, 12.5, 15, 20, 25, 30, 40]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 5, 7.5, 10, 12.5, 15, 19, 20, 25, 30]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 10, 13, 19, 21, 25, 30, 38, 49, 50]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 5, 7.5, 10, 12.5, 15, 20, 25, 30]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [0, 12, 18, 24, 36, 48, 60, 72, 96]
default: deferred
+constraint: min
```
…154 unchanged lines
```datasheet
−label: Spray Polyurethane Foam Minimum Core Density
+label: Spray Polyurethane Foam Core Density
type: range
unit: pcf
…2 unchanged lines
max: 3.5
setpoints: [0.4, 0.5, 0.7, 1.0, 1.4, 1.7, 2.0, 2.5, 3.0, 3.5]
+constraint: min
```
…9 unchanged lines
```datasheet
−label: Spray Polyurethane Foam Minimum Applied Thickness
+label: Spray Polyurethane Foam Applied Thickness
type: range
unit: inches
…4 unchanged lines
setpoints: [0.5, 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 5.5, 6, 7, 8, 10, 12]
default: deferred
+constraint: min
```
…52 unchanged lines
```datasheet
−label: Roof Insulation — Minimum Compressive Resistance
+label: Roof Insulation — Compressive Resistance
type: range
unit: psi
…4 unchanged lines
setpoints: [10, 16, 20, 25, 40, 60, 80, 110, 140]
default: deferred
+constraint: min
```
```datasheet
−label: Under-Slab Insulation — Minimum Compressive Resistance
+label: Under-Slab Insulation — Compressive Resistance
type: range
unit: psi
…4 unchanged lines
setpoints: [10, 13, 15, 25, 40, 60, 100]
default: deferred
+constraint: min
```
```datasheet
−label: Below-Grade Wall Insulation — Minimum Compressive Resistance
+label: Below-Grade Wall Insulation — Compressive Resistance
type: range
unit: psi
…4 unchanged lines
setpoints: [5, 10, 13, 15, 25, 40, 60]
default: deferred
+constraint: min
```
…19 unchanged lines
- "Rigid board cut and fitted between framing"
- "None — the wall is insulated entirely outboard of the framing"
+constraint: any_of
```
…14 unchanged lines
- "Insulated sheathing with an integral water-resistive barrier"
- "None — the wall has no continuous insulation layer"
+constraint: any_of
```
…17 unchanged lines
- "Insulation below the deck between structural framing"
- "None — the roof is insulated at a separate ceiling plane"
+constraint: any_of
```
…30 unchanged lines
- "Rigid board above the roof deck"
- "None — no steep-slope or attic assembly in the project"
+constraint: any_of
```
…13 unchanged lines
- "Rigid board above the structural deck under the finish floor"
- "None — no floor over unconditioned space in the project"
+constraint: any_of
```
…10 unchanged lines
- "Rigid board under the crawl space slab or ground cover"
- "None — no crawl space in the project"
+constraint: any_of
```
…15 unchanged lines
- "Integral to an insulated concrete form wall"
- "None — the below-grade wall is uninsulated"
+constraint: any_of
```
…9 unchanged lines
- "Cellular glass board"
- "None — the slab is uninsulated"
+constraint: any_of
```
…23 unchanged lines
```datasheet
−label: Maximum Smoke-Developed Index
+label: Smoke-Developed Index
type: range
options:
…2 unchanged lines
setpoints: [25, 50, 100, 200, 450]
default: 450
+constraint: max
```
…595 unchanged lines
- "Contractor's own quality control, documented"
default: "Authority Having Jurisdiction"
+constraint: all_of
```
…15 unchanged lines
default:
- "Framing complete, plumb, and at the spacing shown"
+constraint: all_of
```
…20 unchanged lines
```datasheet
−label: Maximum Air Leakage Rate — Air Changes Basis
+label: Air Leakage Rate — Air Changes Basis
type: range
unit: ACH50
…4 unchanged lines
setpoints: [0.4, 0.6, 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 7.0, 10]
default: deferred
+constraint: max
```
```datasheet
−label: Maximum Air Leakage Rate — Envelope Area Basis
+label: Air Leakage Rate — Envelope Area Basis
type: range
unit: cfm/ft² at 75 Pa
…4 unchanged lines
setpoints: [0.04, 0.08, 0.1, 0.15, 0.2, 0.25, 0.3, 0.4, 0.6]
default: deferred
+constraint: max
```
…13 unchanged lines
```datasheet
−label: Maximum Area Represented by Each Spray Foam Core Sample
+label: Area Represented by Each Spray Foam Core Sample
type: range
unit: ft²
…2 unchanged lines
max: 5000
setpoints: [100, 250, 500, 1000, 2000, 5000]
+constraint: max
```
…70 unchanged lines
max: 30
setpoints: [1, 5, 10, 15, 20, 25, 30]
+constraint: min
```
…17 unchanged lines
setpoints: [1, 2, 3, 5, 10]
default: 1
+constraint: min
```
…23 unchanged lines
- "As-built assembly thermal resistance summary for each envelope assembly"
default: "Energy code compliance certificate accepted by the Authority Having Jurisdiction"
+constraint: all_of
```
### The energy code compliance documentation is a condition of the certificate of occupancy in many jurisdictions and shall be treated as a contract deliverable rather than as an informational record.
### Where the as-built assemblies differ from those on which the compliance documentation was based, the Contractor shall report the difference and shall obtain a revised compliance evaluation from the party responsible for the energy analysis before requesting final acceptance.