Cast-in-Place Concrete
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 8
to Rev 9
in Cast-in-Place Concrete.
---
title: Cast-in-Place Concrete
…112 unchanged lines
- "Admixture product data and certificates"
- "Concrete placement plan"
+constraint: all_of
```
…23 unchanged lines
- "Field testing technician certifications"
- "Batch plant qualification records"
+constraint: all_of
```
…22 unchanged lines
- "Record of rejected loads and corrective actions"
- "Defect reports and directed dispositions"
+constraint: all_of
```
…16 unchanged lines
- "National Ready Mixed Concrete Association plant certification"
- "State department of transportation plant approval"
+constraint: any_of
```
…49 unchanged lines
- "Production strength record with calculated standard deviation"
- "Trial mixtures proportioned across a strength range"
+constraint: any_of
```
…86 unchanged lines
default:
- "Footings, foundations, and grade beams"
+constraint: all_of
```
…10 unchanged lines
setpoints: [2500, 3000, 3500, 4000, 4500, 5000, 6000, 7000, 8000, 10000, 12000]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [2500, 3000, 3500, 4000, 4500, 5000, 6000, 7000, 8000, 10000, 12000]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [2500, 3000, 3500, 4000, 4500, 5000, 6000, 8000]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [3000, 3500, 4000, 4500, 5000, 6000, 7000, 8000, 10000, 12000]
default: deferred
+constraint: min
```
…8 unchanged lines
setpoints: [3000, 3500, 4000, 4500, 5000, 6000, 7000, 8000, 10000, 12000, 14000, 16000]
default: deferred
+constraint: min
```
…7 unchanged lines
setpoints: [500, 1000, 1500, 2000, 2500, 3000]
default: 2000
+constraint: min
```
…7 unchanged lines
```datasheet
−label: Maximum Drying Shrinkage
+label: Drying Shrinkage
type: range
unit: "%"
…2 unchanged lines
max: 0.08
setpoints: [0.02, 0.03, 0.035, 0.04, 0.045, 0.05, 0.06, 0.08]
+constraint: max
```
## Where a minimum cementitious materials content is indicated in the datasheet, each mixture shall meet or exceed it.
```datasheet
−label: Minimum Cementitious Materials Content
+label: Cementitious Materials Content
type: range
unit: lb/cy
…2 unchanged lines
max: 800
step: 10
+constraint: min
```
…9 unchanged lines
```datasheet
−label: Maximum Water-Cementitious Materials Ratio
+label: Water-Cementitious Materials Ratio
type: range
options:
min: 0.32
max: 0.65
setpoints: [0.32, 0.36, 0.38, 0.4, 0.42, 0.45, 0.48, 0.5, 0.55, 0.6, 0.65]
+constraint: max
```
…26 unchanged lines
- "Portland cement dual-certified as Type I and Type II under ASTM C150/C150M"
- "Portland-limestone cement Type IL under ASTM C595/C595M"
+constraint: any_of
```
…26 unchanged lines
- "Class F fly ash under ASTM C618"
- "Slag cement under ASTM C989/C989M"
+constraint: any_of
```
### The maximum content of each supplementary cementitious material, and of all of them combined, shall be as indicated in the datasheet, expressed as a percentage by mass of the total cementitious materials.
```datasheet
−label: Maximum Fly Ash Content
+label: Fly Ash Content
type: range
unit: "%"
…2 unchanged lines
max: 50
step: 5
+constraint: max
```
```datasheet
−label: Maximum Slag Cement Content
+label: Slag Cement Content
type: range
unit: "%"
…2 unchanged lines
max: 80
step: 5
+constraint: max
```
```datasheet
−label: Maximum Silica Fume Content
+label: Silica Fume Content
type: range
unit: "%"
…2 unchanged lines
max: 15
step: 1
+constraint: max
```
```datasheet
−label: Maximum Total Supplementary Cementitious Material Content
+label: Total Supplementary Cementitious Material Content
type: range
unit: "%"
…2 unchanged lines
max: 80
step: 5
+constraint: max
```
…33 unchanged lines
setpoints: [0.375, 0.5, 0.75, 1, 1.5, 2]
default: 0.75
+constraint: exact
```
…22 unchanged lines
setpoints: [90, 95, 100, 105, 110, 115, 120, 125]
default: deferred
+constraint: exact
```
…63 unchanged lines
- "Type D water-reducing and retarding admixture under ASTM C494/C494M"
- "Type F high-range water-reducing admixture under ASTM C494/C494M"
+constraint: any_of
```
…44 unchanged lines
max: 10
step: 0.5
+constraint: exact
```
…23 unchanged lines
max: 32
step: 1
+constraint: exact
```
…11 unchanged lines
```datasheet
−label: Maximum Concrete Temperature at Discharge
+label: Concrete Temperature at Discharge
type: range
unit: "°F"
…3 unchanged lines
setpoints: [70, 75, 80, 85, 90, 95]
default: 90
+constraint: max
```
…11 unchanged lines
```datasheet
−label: Maximum Elapsed Time from Batching to Completion of Discharge
+label: Elapsed Time from Batching to Completion of Discharge
type: range
unit: min
…3 unchanged lines
setpoints: [45, 60, 75, 90, 105, 120]
default: 90
+constraint: max
```
…62 unchanged lines
- "Boom or line concrete pump"
- "Direct chute from the truck"
+constraint: all_of
```
…5 unchanged lines
```datasheet
−label: Maximum Free Fall Without a Drop Chute
+label: Free Fall Without a Drop Chute
type: range
unit: ft
…3 unchanged lines
setpoints: [3, 4, 5, 6, 8, 10, 15]
default: 5
+constraint: max
```
…11 unchanged lines
```datasheet
−label: Maximum Lift Depth — Walls and Columns
+label: Lift Depth — Walls and Columns
type: range
unit: in
…3 unchanged lines
setpoints: [12, 18, 24, 30, 36]
default: 18
+constraint: max
```
…55 unchanged lines
setpoints: [0.05, 0.1, 0.15, 0.2, 0.25, 0.3]
default: 0.2
+constraint: exact
```
…16 unchanged lines
- "Evaporation retardant applied between screeding and finishing"
- "Sunshades over the placement area"
+constraint: all_of
```
…22 unchanged lines
- "Heated enclosure with electric or indirect-fired heaters"
- "Ground thawing before placement on grade"
+constraint: all_of
```
…3 unchanged lines
```datasheet
−label: Minimum Compressive Strength Before Exposure to Freezing
+label: Compressive Strength Before Exposure to Freezing
type: range
unit: psi
…3 unchanged lines
setpoints: [500, 1000, 1500, 2000, 2500, 3000, 3500, 4000]
default: 500
+constraint: min
```
…26 unchanged lines
max: 8
setpoints: [1.5, 2, 3, 4, 5, 6, 8]
+constraint: exact
```
…3 unchanged lines
```datasheet
−label: Maximum In-Place Concrete Temperature
+label: In-Place Concrete Temperature
type: range
unit: "°F"
…3 unchanged lines
setpoints: [140, 150, 158, 160, 170, 180]
default: 160
+constraint: max
```
```datasheet
−label: Maximum Temperature Difference Between Core and Surface
+label: Temperature Difference Between Core and Surface
type: range
unit: "°F"
…3 unchanged lines
setpoints: [20, 25, 30, 35, 40, 45, 50]
default: 35
+constraint: max
```
…25 unchanged lines
setpoints: [25, 50, 75, 100, 125, 150]
default: 150
+constraint: max
```
…13 unchanged lines
step: 1
default: 5
+constraint: min
```
…15 unchanged lines
setpoints: [3, 7, 14, 28, 56, 90]
default: 28
+constraint: exact
```
…30 unchanged lines
- "Density and yield of the fresh concrete"
- "Batch and discharge times from the delivery ticket"
+constraint: all_of
```
…101 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…5 unchanged lines
## Distress arising from loading beyond the design basis, from exposure more severe than the exposure classes specified for the element, or from a mixture the Engineer of Record directed over the Contractor's written objection is a design matter rather than a construction defect. {note}