Foundation Drainage
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 5
to Rev 6
in Foundation Drainage.
---
title: Foundation Drainage
…97 unchanged lines
- "Shop drawings for alignment, inverts, cleanouts, and discharge"
- "Installer qualification statement"
+constraint: all_of
```
…26 unchanged lines
- "Manufacturer's written warranties made out to the Owner"
- "Operation and maintenance manual"
+constraint: all_of
```
…98 unchanged lines
```datasheet
−label: Daylight Outlet - Minimum Horizontal Distance from Foundation
+label: Daylight Outlet - Horizontal Distance from Foundation
type: range
unit: ft
…3 unchanged lines
drawing_ref: "civil grading plan"
default: deferred
+constraint: min
```
…69 unchanged lines
drawing_ref: "foundation plan and drainage profile"
default: deferred
+constraint: exact
```
…5 unchanged lines
```datasheet
−label: Perimeter Drain Pipe - Minimum Slope
+label: Perimeter Drain Pipe - Slope
type: range
unit: '%'
min: 0
max: 5
setpoints: [0, 0.5, 0.75, 1, 1.5, 2, 3, 5]
+constraint: min
```
…3 unchanged lines
```datasheet
−label: Perimeter Drain Pipe - Minimum Pipe Stiffness at 5 Percent Deflection
+label: Perimeter Drain Pipe - Pipe Stiffness at 5 Percent Deflection
type: range
unit: psi
min: 28
max: 115
setpoints: [28, 35, 46, 115]
+constraint: min
```
…74 unchanged lines
```datasheet
−label: Envelope Aggregate - Maximum Material Passing the No. 200 Sieve
+label: Envelope Aggregate - Material Passing the No. 200 Sieve
type: range
unit: '%'
…2 unchanged lines
setpoints: [0.5, 1, 2, 3, 5]
default: 2
+constraint: max
```
…15 unchanged lines
drawing_ref: "foundation sections and drainage details"
default: deferred
+constraint: min
```
…9 unchanged lines
drawing_ref: "foundation sections and drainage details"
default: deferred
+constraint: min
```
…9 unchanged lines
drawing_ref: "foundation sections and drainage details"
default: deferred
+constraint: min
```
…42 unchanged lines
```datasheet
−label: Envelope Geotextile - Maximum Apparent Opening Size per ASTM D4751
+label: Envelope Geotextile - Apparent Opening Size per ASTM D4751
type: range
unit: mm
min: 0.15
max: 0.6
setpoints: [0.15, 0.18, 0.22, 0.25, 0.3, 0.43, 0.6]
+constraint: max
```
```datasheet
−label: Envelope Geotextile - Minimum Permittivity per ASTM D4491
+label: Envelope Geotextile - Permittivity per ASTM D4491
type: range
unit: 1/s
min: 0.1
max: 2
setpoints: [0.1, 0.2, 0.5, 1, 1.5, 2]
+constraint: min
```
…19 unchanged lines
```datasheet
−label: Soil-Geotextile - Maximum Gradient Ratio per ASTM D5101
+label: Soil-Geotextile - Gradient Ratio per ASTM D5101
type: range
min: 1
max: 3
setpoints: [1, 1.5, 2, 2.5, 3]
default: 3
+constraint: max
```
…37 unchanged lines
```datasheet
−label: Wall Drainage Composite - Minimum Core Thickness
+label: Wall Drainage Composite - Core Thickness
type: range
unit: in
min: 0.25
max: 1
setpoints: [0.25, 0.375, 0.5, 0.625, 1]
+constraint: min
```
### The minimum in-plane flow rate per unit width of the wall drainage composite, tested in accordance with ASTM D4716, shall be as indicated in the datasheet.
```datasheet
−label: Wall Drainage Composite - Minimum In-Plane Flow Rate per ASTM D4716
+label: Wall Drainage Composite - In-Plane Flow Rate per ASTM D4716
type: range
unit: gpm/ft
min: 1
max: 25
setpoints: [1, 2, 5, 10, 15, 25]
+constraint: min
```
…92 unchanged lines
drawing_ref: "foundation plan and slab sections"
default: deferred
+constraint: exact
```
…19 unchanged lines
```datasheet
−label: Sub-Slab Collector Piping - Maximum Spacing
+label: Sub-Slab Collector Piping - Spacing
type: range
unit: ft
…3 unchanged lines
drawing_ref: "foundation plan"
default: deferred
+constraint: max
```
…23 unchanged lines
```datasheet
−label: Sump Pit - Minimum Interior Diameter
+label: Sump Pit - Interior Diameter
type: range
unit: in
…3 unchanged lines
drawing_ref: "foundation plan and sump pit detail"
default: deferred
+constraint: min
```
…48 unchanged lines
drawing_ref: "pump schedule"
default: deferred
+constraint: exact
```
…71 unchanged lines
```datasheet
−label: Geotextile and Composite - Maximum Exposure Before Covering
+label: Geotextile and Composite - Exposure Before Covering
type: range
unit: days
…2 unchanged lines
setpoints: [3, 7, 14, 30]
default: 14
+constraint: max
```
…54 unchanged lines
- "At the maximum spacing along straight runs"
- "At the sump pit connection"
+constraint: all_of
```
### The maximum cleanout spacing along straight runs shall be as indicated in the datasheet.
```datasheet
−label: Cleanout - Maximum Spacing Along Straight Runs
+label: Cleanout - Spacing Along Straight Runs
type: range
unit: ft
…2 unchanged lines
setpoints: [50, 75, 100, 150, 200]
default: 100
+constraint: max
```
…21 unchanged lines
```datasheet
−label: Envelope Geotextile - Minimum Seam Overlap
+label: Envelope Geotextile - Seam Overlap
type: range
unit: in
…2 unchanged lines
setpoints: [12, 18, 24, 36]
default: 12
+constraint: min
```
…41 unchanged lines
- "Closed-circuit camera inspection of the full pipe length"
default: "Water introduction at the high-point cleanout with observation at the outlet"
+constraint: all_of
```
### Where water introduction is used, the Contractor shall introduce clean water at the high-point cleanout at not less than the rate indicated in the datasheet.
```datasheet
−label: Perimeter Drain Verification - Minimum Water Introduction Rate
+label: Perimeter Drain Verification - Water Introduction Rate
type: range
unit: gpm
min: 5
max: 100
setpoints: [5, 10, 15, 25, 50, 100]
+constraint: min
```
### Continuous discharge shall appear at the outlet within the elapsed time indicated in the datasheet, measured from the start of water introduction.
```datasheet
−label: Perimeter Drain Verification - Maximum Time to Continuous Discharge
+label: Perimeter Drain Verification - Time to Continuous Discharge
type: range
unit: min
min: 2
max: 30
setpoints: [2, 5, 10, 15, 30]
+constraint: max
```
…11 unchanged lines
```datasheet
−label: Sump Pump Verification - Minimum On-Off Cycles
+label: Sump Pump Verification - On-Off Cycles
type: range
unit: cycles
…2 unchanged lines
setpoints: [3, 5, 10]
default: 3
+constraint: min
```
…19 unchanged lines
- "Check valve holds against backflow into the pit"
- "Discharge piping watertight at all joints"
+constraint: all_of
```
…30 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…8 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…22 unchanged lines
- "One spare float switch set for each pump control arrangement"
- "Two spare cleanout covers of each type and size installed"
+constraint: all_of
```
## Spare parts shall be delivered in the manufacturer's original packaging and shall be stored where the Owner directs.
## The Contractor shall record the delivered spare parts, with manufacturer and model designation, in the operation and maintenance manual.