Sanitary Sewer Systems (Site)
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 4
to Rev 5
in Sanitary Sewer Systems (Site).
---
title: Sanitary Sewer Systems (Site)
…149 unchanged lines
- "Existing-sewer connection details, flow management plan, and utility owner approvals"
- "Record-set markup procedure"
+constraint: all_of
```
…21 unchanged lines
- "Cleaning and temporary-control removal certification"
- "Authority Having Jurisdiction and utility owner acceptance documentation"
+constraint: all_of
```
…79 unchanged lines
default:
- "Solid-wall PVC sewer pipe per ASTM D3034"
+constraint: any_of
```
…205 unchanged lines
- "At the property line, easement line, or right-of-way line"
- "At each change of direction exceeding 45 degrees"
+constraint: all_of
```
…391 unchanged lines
```datasheet
−label: Maximum Grade Adjustment Stack Height
+label: Grade Adjustment Stack Height
type: range
unit: in
…2 unchanged lines
setpoints: [0, 6, 8, 12, 16, 24]
default: 12
+constraint: max
```
…13 unchanged lines
- "External chimney seal wrapped over the frame, rings, and cone"
- "Inflow dish insert beneath the cover"
+constraint: all_of
```
…87 unchanged lines
setpoints: [3, 4, 6, 9, 12, 18]
default: 4
+constraint: min
```
…15 unchanged lines
```datasheet
−label: Minimum Embedment Compaction for Class IB, II, and III Materials
+label: Embedment Compaction for Class IB, II, and III Materials
type: range
unit: '% of maximum standard Proctor dry density'
…2 unchanged lines
setpoints: [85, 90, 95, 100]
default: 90
+constraint: min
```
…320 unchanged lines
```datasheet
−label: Maximum Allowable Exfiltration or Infiltration
+label: Allowable Exfiltration or Infiltration
type: range
unit: gal per in. of diameter per mile per day
min: 0
max: 500
setpoints: [0, 25, 50, 100, 200, 500]
+constraint: max
```
…37 unchanged lines
```datasheet
−label: Maximum Allowable Installed Pipe Deflection
+label: Allowable Installed Pipe Deflection
type: range
unit: '%'
…2 unchanged lines
setpoints: [3, 5, 7.5]
default: 5
+constraint: max
```
…25 unchanged lines
derived: "the force main design working pressure at the lowest point of the test section"
default: derived
+constraint: exact
```
…116 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…17 unchanged lines
## Pipe laid at an incorrect slope, a lateral connected with a hand-cut saddle, a structure joint that was never sealed, a casting under-rated for its location, and a pipe material substituted from the one specified are non-conforming work whenever they are discovered, not defects that expire with the warranty. {note}