title: Structural Steel Framing
…2 unchanged lines
When to use: The hot-rolled structural steel frame of a building or structure designed by the Engineer of Record under ANSI/AISC 360: wide-flange beams, girders, and columns, hollow structural sections and pipe used as columns, braces, and beams, channels, angles, tees, plates, and bars, built-up members, crane runway beams, and the headed shear stud connectors, stiffeners, column base plates, and stabilizer plates furnished with them. Covers the material grade for each shape family, the material provisions the seismic force-resisting system imposes on members, fabricator and erector qualification, shop and erection drawings, cutting, hole forming, straightening, cambering, and member marking, architecturally exposed structural steel categories, the shop coating system and its boundary with applied fireproofing and field finishes, erection planning, temporary bracing, column base setting, erection tolerances and the post-erection survey, field touch-up, delivery and storage, and the warranty for the structural steel.
− Not intended for: The design of the bolted and welded connections that join the frame, high-strength bolt assemblies, joint condition, faying surfaces, oversized and slotted openings, and bolting inspection (see [[sync/structural-steel-connections]]); the welding quality program of procedure and welder qualification, consumables, preheat, weld acceptance, and nondestructive examination (see [[sync/welding-requirements]]); cold-formed light-gauge steel studs, joists, and tracks (see [[sync/cold-formed-metal-framing]]); open-web steel joists of every SJI series (see [[sync/steel-joists]]); steel floor and roof deck and its attachment to the supports (see [[sync/steel-deck]]); pre-engineered metal building packages engineered by a manufacturer (see [[sync/metal-building-systems]]); ladders, bollards, gratings, and other loose metal items outside the structural drawings (see [[sync/miscellaneous-metals]]); anchor rods, embedded steel, and their setting (see [[sync/structural-steel-anchor-bolts]]); grouting beneath base plates (see [[sync/grouted-base-plates]]); applied fireproofing materials and their bond verification (see [[sync/fireproofing]]); shop coating materials, dry film thickness, and galvanizing process requirements (see [[sync/shop-painting-and-galvanizing]]); and stainless steel or aluminum structural members.
+ Not intended for: The design of the bolted and welded connections that join the frame, high-strength bolt assemblies, joint condition, faying surfaces, oversized and slotted openings, and bolting inspection (see [[sync/structural-steel-connections]]); the welding quality program of procedure and welder qualification, consumables, preheat, weld acceptance, and nondestructive examination (see [[sync/welding-requirements]]); cold-formed light-gauge steel studs, joists, and tracks (see [[sync/cold-formed-metal-framing]]); open-web steel joists of every SJI series (see [[sync/steel-joists]]); steel floor and roof deck and its attachment to the supports (see [[sync/steel-deck]]); pre-engineered metal building packages engineered by a manufacturer (see [[sync/metal-building-systems]]); ladders, bollards, and other loose metal items outside the structural drawings (see [[sync/miscellaneous-metals]]); gratings (see [[sync/metal-gratings-and-floor-plates]]); anchor rods, embedded steel, and their setting (see [[sync/structural-steel-anchor-bolts]]); grouting beneath base plates (see [[sync/grouted-base-plates]]); applied fireproofing materials and their bond verification (see [[sync/fireproofing]]); shop coating materials, dry film thickness, and galvanizing process requirements (see [[sync/shop-painting-and-galvanizing]]); and stainless steel or aluminum structural members.
---
…1111 unchanged lines
### Bonds and the form of the warranty documents are established under [[sync/warranties-and-bonds]].