Unit Masonry
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 8
to Rev 9
in Unit Masonry.
---
title: Unit Masonry
…131 unchanged lines
- "Grouting procedure"
- "Wall bracing plan"
+constraint: all_of
```
…21 unchanged lines
- "Cold and hot weather construction procedures"
- "Special inspection reports as issued"
+constraint: all_of
```
…23 unchanged lines
- "As-built movement joint locations"
- "Special inspection final report"
+constraint: all_of
```
…5 unchanged lines
```datasheet
−label: Minimum Masonry Contractor Experience
+label: Masonry Contractor Experience
type: range
unit: years
…3 unchanged lines
setpoints: [0, 2, 3, 5, 10, 15]
default: 5
+constraint: min
```
…27 unchanged lines
```datasheet
−label: Sample Panel Minimum Face Area
+label: Sample Panel Face Area
type: range
unit: sq ft
…3 unchanged lines
setpoints: [16, 32, 48, 64, 100]
default: 16
+constraint: min
```
…48 unchanged lines
- "Masonry retaining and below-grade walls"
default: deferred
+constraint: all_of
```
…26 unchanged lines
setpoints: [1500, 1750, 2000, 2250, 2500, 2750, 3000, 3500, 4000, 4500, 5000, 6000]
default: deferred
+constraint: min
```
…26 unchanged lines
```datasheet
−label: Concrete Masonry Unit Net Area Compressive Strength, Minimum
+label: Concrete Masonry Unit Net Area Compressive Strength
type: range
unit: psi
…4 unchanged lines
setpoints: [2000, 2250, 2500, 2750, 3000, 3250, 3500, 3750, 4000, 4500, 5000, 6000]
default: derived
+constraint: min
```
…3 unchanged lines
```datasheet
−label: Clay Masonry Unit Compressive Strength, Minimum
+label: Clay Masonry Unit Compressive Strength
type: range
unit: psi
…4 unchanged lines
setpoints: [2000, 3000, 4000, 5000, 6000, 8000, 10000, 12000, 15000, 20000]
default: derived
+constraint: min
```
…9 unchanged lines
```datasheet
−label: Grout Compressive Strength f'g, Minimum
+label: Grout Compressive Strength f'g
type: range
unit: psi
…4 unchanged lines
setpoints: [2000, 2500, 3000, 3500, 4000, 4500, 5000]
default: derived
+constraint: min
```
…255 unchanged lines
setpoints: [8, 16, 24, 32, 48]
default: 16
+constraint: max
```
…107 unchanged lines
setpoints: [0.5, 0.75, 1, 1.5, 2]
default: deferred
+constraint: exact
```
…150 unchanged lines
```datasheet
−label: Control Joint Maximum Spacing in Concrete Masonry
+label: Control Joint Spacing in Concrete Masonry
type: range
unit: ft
…3 unchanged lines
setpoints: [12, 16, 20, 25, 30, 40]
default: 25
+constraint: max
```
…29 unchanged lines
```datasheet
−label: Expansion Joint Maximum Spacing in Clay Masonry
+label: Expansion Joint Spacing in Clay Masonry
type: range
unit: ft
…4 unchanged lines
setpoints: [12, 16, 20, 25, 30]
default: deferred
+constraint: max
```
…16 unchanged lines
max: 1
setpoints: [0.375, 0.5, 0.625, 0.75, 1]
+constraint: exact
```
…130 unchanged lines
setpoints: [0.125, 0.25]
default: 0.25
+constraint: max
```
…22 unchanged lines
setpoints: [2500, 5000, 10000]
default: derived
+constraint: max
```
…51 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…20 unchanged lines
max: 5
setpoints: [0, 1, 2, 3, 5]
+constraint: min
```
…3 unchanged lines
## Attic stock of veneer units is furnished under [[sync/masonry-anchorage-and-veneer]] or [[sync/brick-masonry]] and is not counted against the quantity above. {note}