…442 unchanged lines
### Where the bottom of a holed jack is below [[parameter: seasonal-high-groundwater-elevation]], the casing shall be a sealed watertight assembly and the jack shall be fitted with a means of detecting fluid loss from the cylinder that places the elevator out of service.
−### A holed jack shall be protected against corrosion by a factory-applied coating and by cathodic protection where the geotechnical report identifies corrosive soil.
+### A holed jack shall be protected against corrosion by a factory-applied coating and by cathodic protection under [[sync/cathodic-protection]] where the geotechnical report identifies corrosive soil.
### The hydraulic fluid shall be as indicated in the datasheet.
…1102 unchanged lines
## Where diagnostic credentials are furnished, the Contractor shall record them in a sealed envelope delivered to the Owner's designated representative and shall not retain a credential the Owner has not authorized in writing after the maintenance period ends.