Wood Flooring
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 3
to Rev 4
in Wood Flooring.
---
title: Wood Flooring
…103 unchanged lines
- "Formaldehyde emission compliance under 40 CFR Part 770"
- "Low-emitting materials and volatile organic compound documentation"
+constraint: all_of
```
…21 unchanged lines
- "Pre-installation conference report"
- "Certification that the moisture control measure matches the measured substrate condition"
+constraint: all_of
```
…22 unchanged lines
- "Sports floor — ASTM F2772 field results and game line record"
- "Attic stock and touch-up material transmittal"
+constraint: all_of
```
…66 unchanged lines
setpoints: [55, 60, 65, 70, 75, 80, 85]
default: 70
+constraint: exact
```
```datasheet
−label: In-Service Interior Relative Humidity, Minimum
+label: Lowest In-Service Interior Relative Humidity
type: range
unit: '% RH'
…3 unchanged lines
setpoints: [15, 20, 25, 30, 35, 40, 45]
default: 30
+constraint: min
```
```datasheet
−label: In-Service Interior Relative Humidity, Maximum
+label: Highest In-Service Interior Relative Humidity
type: range
unit: '% RH'
…3 unchanged lines
setpoints: [40, 45, 50, 55, 60, 65, 70]
default: 50
+constraint: max
```
…10 unchanged lines
```datasheet
−label: Minimum Acclimation Period
+label: Acclimation Period
type: range
unit: days
…2 unchanged lines
step: 1
setpoints: [0, 3, 5, 7, 10, 14, 21]
+constraint: min
```
…9 unchanged lines
```datasheet
−label: Flooring Moisture Content at Installation, Minimum
+label: Lowest Flooring Moisture Content at Installation
type: range
unit: '%'
…3 unchanged lines
step: 0.5
setpoints: [4, 5, 6, 7, 8, 9, 10, 11]
+constraint: min
```
```datasheet
−label: Flooring Moisture Content at Installation, Maximum
+label: Highest Flooring Moisture Content at Installation
type: range
unit: '%'
…3 unchanged lines
step: 0.5
setpoints: [6, 7, 8, 9, 10, 11, 12, 13, 14]
+constraint: max
```
```datasheet
−label: Maximum Flooring-to-Substrate Moisture Content Differential
+label: Flooring-to-Substrate Moisture Content Differential
type: range
unit: percentage points
…3 unchanged lines
step: 1
setpoints: [1, 2, 3, 4, 5]
+constraint: max
```
…12 unchanged lines
```datasheet
−label: Maximum Slab Internal Relative Humidity, ASTM F2170
+label: Slab Internal Relative Humidity, ASTM F2170
type: range
unit: '% RH'
…3 unchanged lines
setpoints: [60, 65, 70, 75, 80, 85, 90, 95, 100]
default: 75
+constraint: max
```
```datasheet
−label: Maximum Moisture Vapor Emission Rate, ASTM F1869
+label: Moisture Vapor Emission Rate, ASTM F1869
type: range
unit: lb/1000 ft²/24 h
…3 unchanged lines
setpoints: [1, 2, 3, 4, 5, 7, 10]
default: 3
+constraint: max
```
```datasheet
−label: Maximum Slab Surface pH
+label: Slab Surface pH
type: range
min: 7
…2 unchanged lines
setpoints: [7, 8, 9, 10, 11, 12]
default: 10
+constraint: max
```
…17 unchanged lines
```datasheet
−label: Maximum Wood Substrate Moisture Content
+label: Wood Substrate Moisture Content
type: range
unit: '%'
…3 unchanged lines
setpoints: [8, 9, 10, 11, 12, 13, 14]
default: 12
+constraint: max
```
…210 unchanged lines
step: 0.0625
setpoints: [0.25, 0.3125, 0.375, 0.5, 0.625, 0.75, 1]
+constraint: exact
```
…6 unchanged lines
step: 0.25
setpoints: [1.5, 2.25, 3, 3.25, 4, 5, 6, 7, 8, 9, 10, 12]
+constraint: exact
```
…6 unchanged lines
step: 0.1
setpoints: [0.6, 1, 2, 3, 4, 5, 6]
+constraint: min
```
…72 unchanged lines
step: 0.0625
setpoints: [0.0625, 0.125, 0.1875, 0.25]
+constraint: max
```
…47 unchanged lines
```datasheet
−label: Minimum Impact Sound Improvement, ASTM E2179
+label: Impact Sound Improvement, ASTM E2179
type: range
unit: dB
min: 0
max: 30
step: 1
+constraint: min
```
…65 unchanged lines
step: 0.25
setpoints: [1, 1.25, 1.5, 1.75, 2, 2.25, 2.5]
+constraint: exact
```
…7 unchanged lines
step: 1
setpoints: [3, 4, 6, 8, 10, 12]
+constraint: max
```
…59 unchanged lines
step: 0.0625
setpoints: [0.25, 0.375, 0.5, 0.625, 0.75, 1, 1.25, 1.5]
+constraint: exact
```
…85 unchanged lines
setpoints: [2, 3, 4, 5]
default: 3
+constraint: min
```
…86 unchanged lines
```datasheet
−label: Maximum Floor Surface Temperature Over Radiant Heating
+label: Floor Surface Temperature Over Radiant Heating
type: range
unit: °F
…3 unchanged lines
setpoints: [75, 80, 85]
default: 80
+constraint: max
```
…173 unchanged lines
step: 1
setpoints: [1, 5, 10, 15, 20, 25, 30, 50]
+constraint: min
```
…8 unchanged lines
step: 1
setpoints: [1, 3, 5, 10, 15, 20, 25, 30]
+constraint: min
```
…9 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…19 unchanged lines
step: 0.5
setpoints: [0, 1, 2, 3, 5, 10]
+constraint: min
```
…2 unchanged lines
## Attic stock shall be packaged, sealed, and labeled with the species, construction, grade, dimensions, color, finish, and production lot, and shall be stored where the Owner directs.
## Wood color and grain vary between production runs, and a cured finish continues to shift in color with age and light exposure. Material from the original lot is the only stock that can produce an inconspicuous repair; flooring purchased years later will match the specification and not the floor. {note}