Air Barriers

Read revision 5

Revision 5 · Oct 12, 2026 +23 −4

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 4 to Rev 5 in Air Barriers.
---
title: Air Barriers
…93 unchanged lines
- "Air barrier continuity shop drawings with keyed transition details"
- "Manufacturer system compatibility documentation"
+constraint: all_of
```
…28 unchanged lines
- "Testing agency qualifications"
- "Transition sequencing and trade responsibility plan"
+constraint: all_of
```
…31 unchanged lines
- "Executed installer and manufacturer warranties"
- "As-built transition details for field-modified conditions"
+constraint: all_of
```
…63 unchanged lines
- "Periodic visits during installation"
- "Final inspection before cover-up"
+constraint: all_of
```
…50 unchanged lines
max: 500
step: 10
+constraint: min
```
…21 unchanged lines
- "Round penetration"
- "Cladding attachment through the plane"
+constraint: all_of
```
…40 unchanged lines
setpoints: [0.001, 0.002, 0.004]
default: 0.004
+constraint: max
```
…15 unchanged lines
setpoints: [0.01, 0.02, 0.04]
default: 0.04
+constraint: max
```
…15 unchanged lines
setpoints: [0.05, 0.10, 0.15, 0.25, 0.30, 0.40]
default: 0.40
+constraint: max
```
…132 unchanged lines
```datasheet
−label: Fluid-Applied Minimum Cured Film Thickness
+label: Fluid-Applied Cured Film Thickness
type: range
unit: mils
…2 unchanged lines
max: 80
step: 5
+constraint: min
```
…7 unchanged lines
```datasheet
−label: Sheet Membrane Minimum Lap Width
+label: Sheet Membrane Lap Width
type: range
unit: in.
…2 unchanged lines
max: 6
setpoints: [2, 2.5, 3, 4, 6]
+constraint: min
```
…66 unchanged lines
- "Opening flashing conforming to AAMA 711 or AAMA 714"
- "Preformed penetration boots"
+constraint: all_of
```
…5 unchanged lines
```datasheet
−label: Maximum Exposure Before Cover-Up
+label: Exposure Before Cover-Up
type: range
unit: months
…2 unchanged lines
max: 12
setpoints: [1, 3, 6, 9, 12]
+constraint: max
```
…200 unchanged lines
max: 20000
setpoints: [2500, 5000, 10000, 20000]
+constraint: max
```
### Field adhesion tests shall meet not less than the minimum adhesion value indicated in the datasheet for the substrate tested.
```datasheet
−label: Minimum Field Adhesion Value
+label: Field Adhesion Value
type: range
unit: psi
…2 unchanged lines
max: 60
setpoints: [5, 10, 16, 20, 30, 40, 60]
+constraint: min
```
…59 unchanged lines
setpoints: [25, 50, 75]
default: 75
+constraint: exact
```
…24 unchanged lines
- "Infrared thermography under pressurization"
- "Chamber or zonal pressurization diagnostics"
+constraint: all_of
```
…50 unchanged lines
setpoints: [1, 2, 5]
default: 2
+constraint: min
```
…16 unchanged lines
max: 20
setpoints: [5, 10, 15, 20]
+constraint: min
```
…15 unchanged lines
## Primers, sealants, and mastics shall be stored, handled, and applied in accordance with their safety data sheets, away from ignition sources, and with the manufacturer's ventilation requirements observed during application.

View current revision