Air Barriers
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 4
to Rev 5
in Air Barriers.
---
title: Air Barriers
…93 unchanged lines
- "Air barrier continuity shop drawings with keyed transition details"
- "Manufacturer system compatibility documentation"
+constraint: all_of
```
…28 unchanged lines
- "Testing agency qualifications"
- "Transition sequencing and trade responsibility plan"
+constraint: all_of
```
…31 unchanged lines
- "Executed installer and manufacturer warranties"
- "As-built transition details for field-modified conditions"
+constraint: all_of
```
…63 unchanged lines
- "Periodic visits during installation"
- "Final inspection before cover-up"
+constraint: all_of
```
…50 unchanged lines
max: 500
step: 10
+constraint: min
```
…21 unchanged lines
- "Round penetration"
- "Cladding attachment through the plane"
+constraint: all_of
```
…40 unchanged lines
setpoints: [0.001, 0.002, 0.004]
default: 0.004
+constraint: max
```
…15 unchanged lines
setpoints: [0.01, 0.02, 0.04]
default: 0.04
+constraint: max
```
…15 unchanged lines
setpoints: [0.05, 0.10, 0.15, 0.25, 0.30, 0.40]
default: 0.40
+constraint: max
```
…132 unchanged lines
```datasheet
−label: Fluid-Applied Minimum Cured Film Thickness
+label: Fluid-Applied Cured Film Thickness
type: range
unit: mils
…2 unchanged lines
max: 80
step: 5
+constraint: min
```
…7 unchanged lines
```datasheet
−label: Sheet Membrane Minimum Lap Width
+label: Sheet Membrane Lap Width
type: range
unit: in.
…2 unchanged lines
max: 6
setpoints: [2, 2.5, 3, 4, 6]
+constraint: min
```
…66 unchanged lines
- "Opening flashing conforming to AAMA 711 or AAMA 714"
- "Preformed penetration boots"
+constraint: all_of
```
…5 unchanged lines
```datasheet
−label: Maximum Exposure Before Cover-Up
+label: Exposure Before Cover-Up
type: range
unit: months
…2 unchanged lines
max: 12
setpoints: [1, 3, 6, 9, 12]
+constraint: max
```
…200 unchanged lines
max: 20000
setpoints: [2500, 5000, 10000, 20000]
+constraint: max
```
### Field adhesion tests shall meet not less than the minimum adhesion value indicated in the datasheet for the substrate tested.
```datasheet
−label: Minimum Field Adhesion Value
+label: Field Adhesion Value
type: range
unit: psi
…2 unchanged lines
max: 60
setpoints: [5, 10, 16, 20, 30, 40, 60]
+constraint: min
```
…59 unchanged lines
setpoints: [25, 50, 75]
default: 75
+constraint: exact
```
…24 unchanged lines
- "Infrared thermography under pressurization"
- "Chamber or zonal pressurization diagnostics"
+constraint: all_of
```
…50 unchanged lines
setpoints: [1, 2, 5]
default: 2
+constraint: min
```
…16 unchanged lines
max: 20
setpoints: [5, 10, 15, 20]
+constraint: min
```
…15 unchanged lines
## Primers, sealants, and mastics shall be stored, handled, and applied in accordance with their safety data sheets, away from ignition sources, and with the manufacturer's ventilation requirements observed during application.