Revision 5 · SynC Standards Team — Specifier, SynC (SynC Platform Team / Platform Standards) ✓ Official · Jun 11, 2026 +7 −10

Migrate datasheet deferrals to drawing_ref + default: deferred
Showing changes from Rev 4 to Rev 5 in Aluminum Entrances and Storefronts.
Tag changes −ADA−Anchorage−Doors−Framing−Glazing−Hardware−Storefront
---
title: Aluminum Entrances and Storefronts
875 unchanged lines
label: Hardware Set Reference
type: free_text
drawing_ref: true
default: "[[drawing: hardware set number from door schedule]]"
+drawing_ref: "door schedule"
+default: deferred
```
238 unchanged lines
- "Through-bolt to steel beam or steel angle"
- "Through-bolt to wood blocking (wood-frame structures only)"
- "Per [[drawing: head anchor detail]]"
default: "Mechanical expansion anchor or screw anchor into concrete slab"
```
7 unchanged lines
- "Mechanical anchor into cured concrete slab"
- "Subsill receptor with thru-anchor to slab"
- "Per [[drawing: sill anchor detail]]"
default: "Mechanical anchor into cured concrete slab"
```
7 unchanged lines
- "Mechanical anchor into adjacent masonry or concrete jamb"
- "Through-bolt to steel jamb or steel framing"
- "Per [[drawing: jamb anchor detail]]"
default: "Mechanical anchor into adjacent masonry or concrete jamb"
```
53 unchanged lines
label: Perimeter Air and Water Control Transition
type: select
+drawing_ref: "perimeter air/water transition detail"
options:
- "Flexible flashing tape lapped over building wrap to frame face"
- "Fluid-applied flashing membrane painted over building wrap and onto frame perimeter"
- "Transition membrane (manufacturer-specific) sealed to both air barrier and frame"
- "Per [[drawing: perimeter air/water transition detail]]"
default: "Fluid-applied flashing membrane painted over building wrap and onto frame perimeter"
```
46 unchanged lines
label: Finish Color
type: free_text
drawing_ref: true
default: "[[drawing: as scheduled — confirm with Architect's finish schedule and sample]]"
+drawing_ref: "finish schedule"
+default: deferred
```
150 unchanged lines
label: AAMA 503 Field Test Required
type: select
+drawing_ref: "field test plan"
options:
- "Not required"
- "Required — one test location per storefront elevation"
- "Required — three test locations per project"
- "Required — schedule per [[drawing: field test plan]]"
default: "Required — one test location per storefront elevation"
```
24 unchanged lines
label: Cleaning Products — Restrictions
type: select
+drawing_ref: "cleaning specifications"
options:
- "Mild detergent and water only — no solvents, no acids, no abrasives"
- "Manufacturer-approved cleaner per finish product data sheet"
- "Per [[drawing: cleaning specifications]]"
default: "Manufacturer-approved cleaner per finish product data sheet"
```
64 unchanged lines
### Warranty exclusions for damage caused by improper cleaning, building movement beyond the system's tested capacity, or modifications by other trades shall be specifically identified in the warranty document; blanket exclusions shall not be accepted.