Fencing and Gates
Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 7
to Rev 8
in Fencing and Gates.
---
title: Fencing and Gates
…118 unchanged lines
- "Finish color samples, full standard color line"
- "Footing concrete mix design or product data"
+constraint: all_of
```
…34 unchanged lines
- "Manufacturer warranty documentation"
- "Care and maintenance instructions with permitted cleaning agents"
+constraint: all_of
```
…75 unchanged lines
- "Ornamental tubular picket fence"
- "Welded wire mesh fence"
+constraint: all_of
```
…24 unchanged lines
max: 12
setpoints: [3, 4, 5, 6, 7, 8, 10, 12]
+constraint: exact
```
…72 unchanged lines
max: 96
setpoints: [0, 12, 18, 24, 30, 36, 42, 48, 60, 72, 84, 96]
+constraint: exact
```
…91 unchanged lines
max: 4.0
setpoints: [1.66, 1.9, 2.375, 2.875, 3.5, 4.0]
+constraint: exact
```
…10 unchanged lines
max: 8.625
setpoints: [2.375, 2.875, 3.5, 4.0, 6.625, 8.625]
+constraint: exact
```
…9 unchanged lines
```datasheet
−label: Chain-Link Line Post Maximum Spacing
+label: Chain-Link Line Post Spacing
type: range
unit: ft
…3 unchanged lines
step: 1
default: 10
+constraint: max
```
…89 unchanged lines
setpoints: [0.375, 0.5, 1.0, 1.75, 2.0, 2.375]
default: 2.0
+constraint: exact
```
…174 unchanged lines
step: 1
default: 3
+constraint: exact
```
…26 unchanged lines
setpoints: [0.5, 1.0, 1.5, 2.0, 3.0, 3.875, 4.0, 6.0]
default: 3.875
+constraint: exact
```
…197 unchanged lines
step: 1
default: 0
+constraint: exact
```
…35 unchanged lines
```datasheet
−label: Maximum Bottom-of-Fence Clearance to Grade
+label: Bottom-of-Fence Clearance to Grade
type: range
unit: in
…3 unchanged lines
setpoints: [0, 1, 2, 3, 4, 6]
default: 2
+constraint: max
```
…57 unchanged lines
max: 5000
setpoints: [2500, 3000, 3500, 4000, 4500, 5000]
+constraint: min
```
…22 unchanged lines
max: 60
setpoints: [12, 18, 24, 30, 36, 42, 48, 54, 60]
+constraint: min
```
…10 unchanged lines
max: 24
setpoints: [6, 8, 10, 12, 15, 18, 24]
+constraint: min
```
…18 unchanged lines
max: 72
setpoints: [18, 24, 30, 36, 42, 48, 60, 72]
+constraint: min
```
…8 unchanged lines
max: 36
setpoints: [8, 10, 12, 15, 18, 24, 30, 36]
+constraint: min
```
…10 unchanged lines
max: 96
setpoints: [24, 30, 36, 42, 48, 60, 72, 84, 96]
+constraint: min
```
…8 unchanged lines
max: 48
setpoints: [12, 15, 18, 24, 30, 36, 42, 48]
+constraint: min
```
…20 unchanged lines
- "Overhead pivot"
- "Pedestrian swing"
+constraint: all_of
```
…10 unchanged lines
max: 60
setpoints: [6, 8, 10, 12, 14, 16, 20, 24, 30, 36, 48, 60]
+constraint: exact
```
…10 unchanged lines
max: 72
setpoints: [24, 30, 32, 36, 42, 48, 60, 72]
+constraint: exact
```
…185 unchanged lines
max: 6
setpoints: [0, 1, 2, 3, 4, 6]
+constraint: max
```
…398 unchanged lines
setpoints: [1, 2, 3, 5]
default: 1
+constraint: min
```
…18 unchanged lines
max: 25
setpoints: [1, 5, 10, 15, 20, 25]
+constraint: min
```
…8 unchanged lines
max: 10
setpoints: [1, 2, 3, 5, 7, 10]
+constraint: min
```
…25 unchanged lines
- "Operator programming and limit-setting tool"
- "Touch-up coating in each finish color furnished"
+constraint: all_of
```
## Spare parts shall be the same product as the installed item, delivered in the manufacturer's packaging and identified with the order designation.
## The Contractor shall furnish the gate operator manufacturer's recommended spare parts list at closeout.