Overhead Coiling Doors

Read revision 5

Revision 5 · Oct 12, 2026 +16 −2

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 4 to Rev 5 in Overhead Coiling Doors.
---
title: Overhead Coiling Doors
…100 unchanged lines
- "Fire door listing documentation"
- "Operator listing and UL 325 documentation with wiring diagram"
+constraint: all_of
```
…23 unchanged lines
- "Installer qualification record"
- "Installation, adjustment, and maintenance instructions"
+constraint: all_of
```
…29 unchanged lines
- "UL 325 functional test record"
- "Keys and key record"
+constraint: all_of
```
…103 unchanged lines
```datasheet
−label: Maximum Whole-Door U-Factor
+label: Whole-Door U-Factor
type: range
unit: "Btu/h·ft²·°F"
…3 unchanged lines
setpoints: [0.2, 0.25, 0.3, 0.35, 0.4, 0.5, 0.6, 0.8, 1.0, 1.45]
default: derived
+constraint: max
```
…5 unchanged lines
```datasheet
−label: Maximum Air Leakage at 1.57 psf
+label: Air Leakage at 1.57 psf
type: range
unit: "cfm/ft²"
…3 unchanged lines
setpoints: [0.1, 0.2, 0.3, 0.4, 0.5, 0.75, 1.0, 1.5]
default: derived
+constraint: max
```
…31 unchanged lines
setpoints: [0, 20, 45, 60, 90, 180, 240]
default: deferred
+constraint: min
```
…92 unchanged lines
setpoints: [10000, 20000, 50000, 100000, 200000, 300000, 500000, 1000000]
default: 20000
+constraint: min
```
…224 unchanged lines
default:
- "Bottom bar astragal"
+constraint: all_of
```
…184 unchanged lines
- "Fire alarm interface for a fire-rated door"
- "Audible and visible motion warning on close"
+constraint: all_of
```
…21 unchanged lines
default:
- "Monitored sensing edge on the bottom bar"
+constraint: all_of
```
…181 unchanged lines
max: 10
setpoints: [1, 2, 3, 5, 10]
+constraint: min
```
…7 unchanged lines
max: 5
setpoints: [1, 2, 3, 5]
+constraint: min
```
…7 unchanged lines
max: 20
setpoints: [1, 5, 10, 15, 20]
+constraint: min
```
…22 unchanged lines
- "Touch-up finish for each factory finish and color"
default: []
+constraint: all_of
```
## A fusible link is consumed by the heat that releases it, and a spare on hand is what gets a fire door reset the same day. A sensing edge is cut by a forklift and a photo eye is knocked off its bracket, and either one takes the door out of momentary operation until it is replaced. Seal stock and touch-up finish are the consumables the Owner's own staff fits. The quantities follow the door count and how far the Owner is from the nearest dealer. {note}