title: Rough Carpentry
…2 unchanged lines
description: >
When to use: Non-finish structural and utility wood framing and blocking. Covers dimension lumber framing (studs, plates, sills, joists, rafters, headers, ledgers); species, grade, and grade stamps under an ALSC-accredited grading agency and the National Grading Rule; design values per the AWC NDS; moisture content (S-DRY / MC19 / KD); wall, roof, and floor sheathing in plywood (DOC PS 1) and OSB (DOC PS 2) with APA span ratings and Exposure 1 bond classification; wood structural panel attachment and nailing; rooftop blocking, nailers, cant strips, curbs, and concealed wood grounds and furring; pressure-preservative-treated wood per the AWPA Use Category System and the IBC locations that require it; fire-retardant-treated (FRT) wood for interior Type III, IV, and V applications; and corrosion-resistant fasteners and metal framing connectors (joist hangers, framing anchors, post bases) compatible with treated wood and exterior service.
− Not intended for: Finish and architectural millwork ([[syncs/architectural-wood-trim-and-paneling]]); casework ([[syncs/wood-and-laminate-casework]]); shop-fabricated structural glued-laminated timber, cross-laminated timber, and other mass timber and engineered wood products; prefabricated wood trusses; cold-formed steel framing ([[syncs/cold-formed-metal-framing]]); and concrete formwork lumber.
+ Not intended for: Finish and architectural millwork ([[sync/architectural-wood-trim-and-paneling]]); casework ([[sync/wood-and-laminate-casework]]); shop-fabricated structural glued-laminated timber, cross-laminated timber, and other mass timber and engineered wood products; prefabricated wood trusses; cold-formed steel framing ([[sync/cold-formed-metal-framing]]); and concrete formwork lumber.
---
…16 unchanged lines
### Rough carpentry interfaces with several adjacent scopes, each governed by its own standard and coordinated here at the framing interface only. {note}
−### Fire blocking and draft stopping within concealed framing cavities shall be coordinated with [[syncs/firestopping]].
+### Fire blocking and draft stopping within concealed framing cavities shall be coordinated with [[sync/firestopping]].
−### Rooftop blocking, nailers, cant strips, and curbs that receive membrane roofing shall be coordinated with [[syncs/membrane-roofing]].
+### Rooftop blocking, nailers, cant strips, and curbs that receive membrane roofing shall be coordinated with [[sync/membrane-roofing]].
−### Wood blocking and nailers that receive sheet metal flashing, copings, gravel stops, and trim shall be coordinated with [[syncs/sheet-metal-flashing-and-trim]].
+### Wood blocking and nailers that receive sheet metal flashing, copings, gravel stops, and trim shall be coordinated with [[sync/sheet-metal-flashing-and-trim]].
−### Where cold-formed steel framing replaces or adjoins wood framing in the same assembly, the steel framing shall be governed by [[syncs/cold-formed-metal-framing]].
+### Where cold-formed steel framing replaces or adjoins wood framing in the same assembly, the steel framing shall be governed by [[sync/cold-formed-metal-framing]].
−### Concealed blocking and backing for the attachment of finish carpentry shall be coordinated with [[syncs/architectural-wood-trim-and-paneling]] and [[syncs/wood-and-laminate-casework]].
+### Concealed blocking and backing for the attachment of finish carpentry shall be coordinated with [[sync/architectural-wood-trim-and-paneling]] and [[sync/wood-and-laminate-casework]].
# Referenced Standards {toc}
…292 unchanged lines
```
−## Cant strips at the base of walls, curbs, and parapets shall be installed to provide the angled transition the membrane base flashing requires, and shall be coordinated with [[syncs/membrane-roofing]].
+## Cant strips at the base of walls, curbs, and parapets shall be installed to provide the angled transition the membrane base flashing requires, and shall be coordinated with [[sync/membrane-roofing]].
−## Wood nailers and blocking that receive sheet metal copings, gravel stops, and edge metal shall be coordinated with [[syncs/sheet-metal-flashing-and-trim]] for size, attachment, and continuity.
+## Wood nailers and blocking that receive sheet metal copings, gravel stops, and edge metal shall be coordinated with [[sync/sheet-metal-flashing-and-trim]] for size, attachment, and continuity.
# Wood Structural Panels {toc}
…274 unchanged lines
## Fire Blocking and Draft Stopping {toc}
−### Fire blocking shall be installed in concealed framing spaces to cut off the concealed draft path at the locations required by the building code, and shall be coordinated with [[syncs/firestopping]].
+### Fire blocking shall be installed in concealed framing spaces to cut off the concealed draft path at the locations required by the building code, and shall be coordinated with [[sync/firestopping]].
### Fire blocking shall be installed at the locations [[drawing: as indicated on the architectural drawings and required by the adopted building code]].
…119 unchanged lines
## The warranty shall not relieve the Contractor of liability for concealed non-conforming work, including the use of untreated wood at locations requiring treatment, discovered after the warranty period.