Signage

Revision 4 · SynC Standards Team — Specifier, SynC (SynC Platform Team / Platform Standards) ✓ Official · Jun 11, 2026 +1 −1

Migrate datasheet deferrals to drawing_ref + default: deferred
Showing changes from Rev 3 to Rev 4 in Signage.
Tag changes −ADA−Architectural−Egress−Signage
---
title: Signage
102 unchanged lines
label: Governing Accessibility Standard
type: select
+drawing_ref: true
options:
- "ICC A117.1 and ADA 2010 — both apply, more stringent governs"
- "ICC A117.1 only (per adopted building code)"
- "ADA 2010 Standards only"
- "Local amended accessibility standard — see drawings"
default: "ICC A117.1 and ADA 2010 — both apply, more stringent governs"
```
462 unchanged lines
### The Contractor shall warrant the installation of all signs, including correct mounting heights and locations against the governing accessibility standard, correct latch-side location and clear approach for tactile signs, secure attachment to the wall or structure, and proper electrical connection of illuminated signs.
### Deficiencies discovered during the warranty period that are attributable to installation workmanship — including loose or fallen signs, tactile signs mounted at the wrong height or location, and illuminated signs that fail to operate or to maintain emergency illumination — shall be corrected by the Contractor at no cost to the Owner.

View current revision