These are the standards in the SynC Standards library that cover ASHRAE 90.1. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Thermal insulation installed in the opaque building envelope of commercial, institutional, multifamily, and residential buildings, covering above-grade wall cavity and continuous insulation, low-slope and steep-slope roof and attic insulation, floors and ceilings over unconditioned space, crawl space enclosures, below-grade foundation walls, and under-slab and slab-edge insulation. Covers all principal insulation forms sold in the North American market: mineral fiber batt, blanket, and board; loose-fill and dense-packed cellulose, fiberglass, and mineral wool; extruded, expanded, and graphite-enhanced polystyrene board; polyisocyanurate board; cellular glass; wood fiber and cellulosic board; spray-applied polyurethane foam; and reflective insulation and radiant barriers. Also covers the thermal resistance basis used to demonstrate energy code compliance, surface burning and foam plastic fire requirements, vapor retarder classification and placement, air barrier coordination, thermal bridge mitigation, and field verification before assemblies are concealed.
General-purpose, field- or factory-installed air-moving equipment serving commercial, institutional, and light-industrial HVAC systems. Covers centrifugal fans (housed and plenum/plug type), axial fans (vaneaxial, tubeaxial, and propeller), inline (cabinet and tubular) fans, utility/SWSI exhaust fans, roof- and wall-mounted power ventilators (upblast and downblast), ceiling-mounted exhaust fans, and dedicated kitchen grease-exhaust fans. Addresses aerodynamic and sound rating and certification (AMCA 210 / 300 / 211 / 311), Fan Energy Index compliance under ASHRAE 90.1 (AMCA 208), AMCA construction class and drive arrangement, direct-drive and belt-drive selection, induction and electronically commutated (EC) motors, bearings, materials and finishes, spark-resistant construction for hazardous exhaust (AMCA 99), accessories, vibration isolation, and the electrical and controls interface to variable-frequency drives and the building automation system.
Field-applied thermal insulation for mechanical piping, ductwork, and equipment in commercial, institutional, and light-industrial buildings. Covers insulation of heating hot water, steam, steam condensate, and other hot service piping; chilled water, dual-temperature, and other below-ambient service piping that requires a continuous vapor barrier; HVAC supply, return, outside-air, and exhaust ductwork (concealed and exposed, indoor and outdoor); and mechanical equipment such as tanks, breechings, pumps, and heat exchangers. Includes selection of insulation material by service (mineral or glass fiber, closed-cell elastomeric, rigid cellular phenolic, cellular glass, and calcium silicate for high temperature), insulation thickness by the adopted edition of ASHRAE 90.1, jacketing and vapor retarders (all-service jacket indoors, PVC fitting covers, metal jacket outdoors and in mechanical rooms), insulated pipe supports and protection shields, penetration coordination, and the condensation-control provisions that govern cold-service work.
Factory-assembled, self-contained packaged units with an integral direct-expansion refrigeration circuit, set on a roof curb and serving a field-installed duct distribution system. Covers cooling-only, gas-fired, electric resistance, hydronic, and reverse-cycle heat pump heating configurations; constant-volume, multi-speed, and variable-air-volume supply fans; air-side economizers, powered relief, minimum outdoor air control, demand-controlled ventilation, and integral exhaust air energy recovery; the cabinet, filtration, drain pan, and roof curb; the refrigerant, its safety group, and the detection and mitigation provisions that go with mildly flammable refrigerants; unit-mounted controls and their interface to the building automation system; and the setting, connection, startup, and balancing of the installed unit.