SynC · Topic
These are the standards in the SynC Standards library that cover Reinforcement. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Cast-in-place concrete equipment pads and housekeeping pads that receive mechanical, electrical, and plumbing equipment - generators, pad-mounted and dry-type transformers, switchgear and switchboard lineups, chillers, air handlers, condensing units, pumps, compressors, boilers, and similar equipment - whether the pad bears on grade, on an interior finished floor, on a structural slab, or on an exterior platform. Covers the decisions a pad standard actually owns: pad geometry and height, attachment to the supporting concrete, reinforcement method, cast-in and post-installed equipment anchorage, cast-in raceway and grounding provisions, liquid containment, surface finish and grout bed, isolation from adjacent construction, dimensional and anchorage tolerances, and the verification performed before concrete is placed and before equipment is set.
Steel reinforcement for cast-in-place structural concrete: deformed and plain reinforcing bars, welded wire reinforcement, headed deformed bars, and the lap, mechanical, end-bearing, and welded splices that join them. Covers the bar standard and grade for each reinforcement class, the bars the seismic-force-resisting system requires, corrosion-protected reinforcement and the system that provides it, fabrication and bending, placement, spacing, and concrete cover, the splice policy for each splice type, welding of reinforcement under AWS D1.4, placement tolerances, the pre-placement inspection, special inspection of reinforcement, and the delivery, storage, and handling of coated and uncoated steel.
The assembled unit masonry wall. Load-bearing walls, shear walls, non-load-bearing partitions, composite and multi-wythe walls, the masonry backup wythe of a cavity wall, and pilasters and piers, built from concrete masonry units alone or from concrete masonry units combined with clay brick. Covers the assembly design values (specified masonry compressive strength, the unit and grout strengths that follow from it, and the mortar type for each wall class), grouting extent and the cells that receive it, bar reinforcement and joint reinforcement, corrosion protection of embedded metal, wythe ties and intersecting-wall connections, bond beams and lintels, bond pattern, bedding, and joint profile, control and expansion joints in the assembly, the prescriptive seismic detailing the seismic design category invokes, bracing of walls under construction, tolerances tightened for exposed work, and the strength verification and special inspection program.