These are the standards in the SynC Standards library that cover Steel. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Spray-applied fire-resistive materials (SFRM) and intumescent fire-resistive materials (IFRM) applied to structural steel, structural concrete, and composite steel deck to achieve hourly fire-resistance ratings required by the International Building Code. Covers cementitious SFRM and mineral-fiber SFRM applied to concealed structural framing, and intumescent mastic and thin-film intumescent coatings applied to exposed-to-view structural steel where architectural finish is required. Addresses surface preparation, primer compatibility, application thickness based on W/D and A/P ratios, density, bond and cohesion/adhesion, in-place verification per AWCI Technical Manual 12-A, ICC-ES AC23 acceptance criteria, and inspection of installed work prior to concealment by ceilings, walls, and finishes.
Structural cold-formed steel framing designed under AISI S100 and AISI S240 and, where the framing participates in a seismic force-resisting system, AISI S400. Covers load-bearing stud walls, exterior non-load-bearing wind-bearing wall framing in both infill and bypass arrangements, cold-formed steel floor joists, roof rafters, and trusses, cold-formed steel shear walls and braced walls, and the parapet, canopy, and soffit framing that carries calculated load. Addresses the division of design responsibility between the Engineer of Record and the specialty engineer, sheet steel and metallic coating selection, member designation and identification, out-of-plane deflection criteria, movement accommodation at the head of wall, bridging and bracing, screwed, welded, powder-actuated, clinched, and bolted connections, opening and built-up member framing, web penetrations and field modification, erection tolerances, listed fire-resistance-rated assemblies, and field inspection.
Factory-fabricated sheet-steel lockers and their doors, latching, locking, trim, interior equipment, and anchorage, in knocked-down or welded construction, for school corridors, athletic and team rooms, employee and industrial change rooms, public recreation, and day-use storage. Covers substrate selection and corrosion protection, component sheet thickness, tier and opening configuration, door ventilation, latching and locking including electronic locks, powder-coat finish performance, tops, bases and closure trim, accessible lockers under the ADA Standards and ICC A117.1, and floor, wall, and seismic anchorage.
Shop-fabricated metal stairs and railing systems for commercial, institutional, and industrial buildings — egress and convenience stairs built as steel pan stairs with concrete fill, steel plate (formed plate) stairs, and bar-grating-tread stairs, including their stringers, treads, risers, landings, and supporting framing, together with the handrails and guards (guardrails) of steel, aluminum, or stainless pipe, tube, and picket. Covers structural design for the IBC stair uniform live load and concentrated load, deflection and vibration serviceability, tread and riser dimensions and slip-resistant nosings to the IBC means-of-egress provisions, the IBC structural loads on handrails and guards (concentrated, uniform, and infill), shop and field welding to AWS D1.1, bolted and anchored connections, hot-dip galvanizing and shop priming, and field finishing.
Exterior metal cladding installed on the above-grade wall enclosure of commercial, institutional, and multifamily buildings. Covers the four principal panel families — factory-foamed insulated metal panels (IMP), single-skin formed and profiled panels, metal composite material panels (MCM/ACM), and flat plate or cassette panels — installed as concealed-fastener or exposed-fastener systems and, where specified, as pressure-equalized or drained-and-back-ventilated rainscreens. Addresses the air, water, structural, thermal, and fire performance the assembly shall demonstrate; the metal substrate and its gauge or thickness; the core and insulation type; the coil and panel finishes with their weathering warranties; the attachment, sub-girt, and support framing; the panel joints and sealants; the interface to flashing, trim, and the air/water barrier behind the panel; and the laboratory and field testing that verifies the installed wall. Addresses the NFPA 285 fire-propagation triggers in the IBC that govern combustible-core panels on Type I through IV construction.
Shop-fabricated miscellaneous steel fabrications that are not part of the primary structural frame and are not stairs or railings — fixed steel ladders with cages or ladder safety systems, ship's ladders, steel pipe and tube bollards (fixed, removable, and structural impact protection), loose steel lintels and masonry shelf angles, steel edge angles and nosings, loose embedded steel furnished for casting into concrete by others (embed plates, weld plates, anchor channels), steel bar gratings and floor (checkered) plate covers and frames, trench and pit frames and covers, equipment supports and rooftop dunnage and steel framing that is not part of the building frame, guard rails and wheel guards for equipment protection, and other miscellaneous steel framing. Covers materials (carbon steel, structural tubing, pipe, stainless where used), hot-dip galvanizing and field repair, shop priming and surface preparation, welding, mechanical fasteners and anchors, and shop and erection tolerances. Applicable to commercial, institutional, industrial, and multi-family buildings.
Cold-formed steel deck for floor and roof construction in commercial, institutional, industrial, and multi-family buildings. Covers composite floor deck (acting compositely with structural concrete topping), non-composite form deck (acting as a permanent stay-in-place form for a concrete slab), and roof deck profiles (Type B wide-rib, Type N deep-rib, Type A narrow-rib, Type F intermediate-rib). Addresses material grade and galvanized coating selection (G60, G90), deck profile and depth, gauge, attachment to supports (arc spot welds, powder-actuated fasteners, screws), side-lap fastening, diaphragm action, concrete fill for composite slabs, openings and reinforcement, accessories (closures, pour stops, ridge and valley plates), and field inspection.
Open-web steel joists and joist girders furnished by Steel Joist Institute member manufacturers under ANSI/SJI 100 and erected under ANSI/SJI 200. Covers K-series and KCS joists, LH-series and DLH-series long-span joists, G-series joist girders, and CJ-series composite joists. Addresses the delegated-design relationship between the Engineer of Record and the joist manufacturer, joist and erector qualification, chord and web steel selection, deflection and floor-vibration criteria, camber policy, bearing seat depth and end anchorage, bridging type and attachment, headers at framed openings, chord extensions, erection stability and erection bridging under OSHA 29 CFR 1926 Subpart R, erection tolerances, shop coating selection, field touch-up, and field inspection of joist work.
The bolted and welded connections that join hot-rolled structural steel framing members into a load-carrying structure: simple shear connections, fully restrained and partially restrained moment connections, vertical and horizontal bracing connections and their gusset plates, column splices, and the steel side of column base plate connections. Covers the assignment of connection design responsibility under AISC 303, the joint condition (snug-tight, pretensioned, or slip-critical) for each connection class, high-strength bolt assemblies under ASTM F3125 and their finish, the RCSC pretensioning methods and pre-installation verification, faying surface slip class and treatment, bolt hole types, the backing, weld tab, and access hole configurations at connection groove welds, load sharing between bolts and welds, the connection provisions AISC 341 imposes on the seismic force-resisting system, bolting inspection, and the handling of fastener assemblies.
Hot-rolled structural steel framing for commercial, institutional, and industrial buildings. Covers wide-flange beams and columns, hollow structural sections (HSS), channels, angles, plates, anchor rods, and all connection materials. Addresses fabrication, erection, bolted connections (bearing and slip-critical), welded connections, high-strength bolt pretensioning, shop and field coatings, surface preparation, camber, tolerances, special inspection, and nondestructive examination. Applicable to buildings in all seismic design categories; seismic-specific requirements follow AISC 341 where triggered.