Self-Adhering Sheet Waterproofing

Read revision 4

Revision 4 · Oct 12, 2026 +38 −11

Datasheet constraints: every range, checkbox and listbox field now states its direction
Showing changes from Rev 3 to Rev 4 in Self-Adhering Sheet Waterproofing.
---
title: Self-Adhering Sheet Waterproofing
…100 unchanged lines
- "Watertightness test plan"
- "Sample warranty forms"
+constraint: all_of
```
…27 unchanged lines
- "Field watertightness and adhesion test reports"
- "Indexed photographic record of detail locations"
+constraint: all_of
```
…25 unchanged lines
- "Record drawings"
- "Membrane repair procedure"
+constraint: all_of
```
…16 unchanged lines
```datasheet
−label: Minimum Applicator Experience
+label: Applicator Experience
type: range
unit: 'years'
min: 0
max: 20
setpoints: [0, 2, 3, 5, 10, 20]
+constraint: min
```
…7 unchanged lines
```datasheet
−label: Manufacturer Field Representative Minimum Site Visits
+label: Manufacturer Field Representative Site Visits
type: range
unit: 'visits'
min: 0
max: 12
setpoints: [0, 1, 2, 4, 6, 12]
+constraint: min
```
…40 unchanged lines
max: 400
setpoints: [25, 50, 100, 200, 400]
+constraint: min
```
…23 unchanged lines
```datasheet
−label: Minimum Hydrostatic Head Resistance (ASTM D5385)
+label: Hydrostatic Head Resistance (ASTM D5385)
type: range
unit: 'ft'
…3 unchanged lines
setpoints: [0, 5, 10, 25, 50, 100, 150, 200, 250]
default: derived
+constraint: min
```
…55 unchanged lines
max: 180
setpoints: [40, 60, 80, 100, 120, 160, 180]
+constraint: min
```
…12 unchanged lines
setpoints: [1, 2]
default: 1
+constraint: exact
```
…5 unchanged lines
```datasheet
−label: Minimum Peel Adhesion to Primed Concrete (ASTM D903)
+label: Peel Adhesion to Primed Concrete (ASTM D903)
type: range
unit: 'lbf/in'
min: 2
max: 15
step: 1
+constraint: min
```
…37 unchanged lines
```datasheet
−label: Minimum Concrete Age Before Membrane
+label: Concrete Age Before Membrane
type: range
unit: 'days'
…2 unchanged lines
setpoints: [3, 5, 7, 14, 21, 28]
default: 7
+constraint: min
```
…12 unchanged lines
- "Anhydrous calcium chloride to ASTM F1869"
- "Electronic moisture meter per the membrane manufacturer's procedure"
+constraint: any_of
```
…5 unchanged lines
```datasheet
−label: Maximum Concrete Surface Profile (ICRI 310.2R CSP)
+label: Concrete Surface Profile (ICRI 310.2R CSP)
type: range
unit: 'CSP'
min: 1
max: 5
setpoints: [1, 2, 3, 4, 5]
+constraint: max
```
…31 unchanged lines
```datasheet
−label: Minimum Air and Substrate Temperature at Application
+label: Air and Substrate Temperature at Application
type: range
unit: '°F'
min: 0
max: 60
setpoints: [0, 20, 25, 32, 40, 50, 60]
+constraint: min
```
…13 unchanged lines
```datasheet
−label: Maximum Membrane Exposure Before Cover
+label: Membrane Exposure Before Cover
type: range
unit: 'days'
min: 0
max: 90
setpoints: [0, 1, 3, 7, 14, 30, 60, 90]
+constraint: max
```
…25 unchanged lines
```datasheet
−label: Minimum Side Lap
+label: Side Lap
type: range
unit: 'in'
min: 2
max: 6
setpoints: [2, 2.5, 3, 4, 6]
+constraint: min
```
### The minimum end lap between successive sheets shall be as indicated in the datasheet.
```datasheet
−label: Minimum End Lap
+label: End Lap
type: range
unit: 'in'
min: 2
max: 12
setpoints: [2, 2.5, 3, 4, 6, 12]
+constraint: min
```
…55 unchanged lines
setpoints: [2, 4, 6, 8, 10, 12]
default: deferred
+constraint: min
```
…82 unchanged lines
setpoints: [0.016, 0.031, 0.0625, 0.125]
default: 0.0625
+constraint: max
```
…38 unchanged lines
max: 0.5
setpoints: [0.0625, 0.125, 0.25, 0.5]
+constraint: min
```
…31 unchanged lines
```datasheet
−label: Drainage Composite Minimum In-Plane Flow Rate
+label: Drainage Composite In-Plane Flow Rate
type: range
unit: 'gal/min per ft of width'
min: 1
max: 40
step: 1
+constraint: min
```
…71 unchanged lines
- "Flood test to ASTM D5957"
- "Visual inspection of the completed membrane before cover"
+constraint: all_of
```
…18 unchanged lines
setpoints: [1, 2, 3, 4]
default: 2
+constraint: exact
```
…8 unchanged lines
setpoints: [24, 48, 72]
default: 24
+constraint: min
```
…38 unchanged lines
max: 10000
setpoints: [500, 1000, 2500, 5000, 10000]
+constraint: max
```
…52 unchanged lines
max: 20
setpoints: [0, 1, 2, 5, 10, 15, 20]
+constraint: min
```
…12 unchanged lines
setpoints: [1, 2, 3, 5]
default: 2
+constraint: min
```
…11 unchanged lines
### Exclusions for structural failure of the building, for damage by other trades after the membrane was protected and accepted, and for alterations to the assembly by others are customary. {note}