Fencing and Gates

Revision 4 · SynC Standards Team — Specifier, SynC (SynC Platform Team / Platform Standards) ✓ Official · Jun 11, 2026 +6 −12

Migrate datasheet deferrals to drawing_ref + default: deferred
Showing changes from Rev 3 to Rev 4 in Fencing and Gates.
Tag changes −Civil−Industrial−Outdoor−Security
---
title: Fencing and Gates
200 unchanged lines
- "With privacy slats or windscreen — increased solidity accounted for"
- "Solid infill panels — full wind area"
- "Per structural design on drawings"
default: "Open fabric / pickets — no privacy slats or windscreen"
```
194 unchanged lines
- "7 ft (industrial / utility)"
- "8 ft (security perimeter)"
- "Per fence elevation on drawings"
default: "6 ft (standard commercial perimeter)"
```
116 unchanged lines
label: Picket Top Treatment
type: select
+drawing_ref: true
options:
- "Flush / smooth top (pedestrian areas)"
- "Extended picket (spear / point — climb deterrent)"
- "Tri-finial / decorative"
- "Per drawings"
default: "Extended picket (spear / point — climb deterrent)"
```
27 unchanged lines
label: Ornamental Fence Finish Color
type: select
drawing_ref: true
+drawing_ref: "architectural finish schedule"
options:
- "Black"
- "Bronze / dark brown"
- "White"
- "Per architectural finish schedule"
default: "Black"
```
41 unchanged lines
label: Barbed-Wire Topping
type: radio
+drawing_ref: "security elevation"
options:
- "Not provided"
- "3-strand single-arm outrigger (angled outward)"
- "6-strand V-arm outrigger (both sides)"
- "Per security elevation on drawings"
default: "Not provided"
```
20 unchanged lines
label: High-Security Topping
type: radio
+drawing_ref: "security design"
options:
- "Not provided"
- "Concertina razor coil"
- "Flat-wrap razor ribbon"
- "Per security design on drawings"
default: "Not provided"
```
117 unchanged lines
- "Single-leaf swing"
- "Double-leaf swing (drive openings)"
- "Per gate schedule on drawings"
default: "Single-leaf swing"
```
132 unchanged lines
- "36 in (single accessible passage)"
- "48 in (wide passage)"
- "Per drawings"
default: "36 in (single accessible passage)"
```
31 unchanged lines
label: Gate Operator Type
type: radio
+drawing_ref: "gate schedule"
options:
- "Slide-gate operator (cantilever / overhead slide)"
- "Swing-gate operator (single or dual arm)"
- "Per gate type on drawings"
default: "Slide-gate operator (cantilever / overhead slide)"
```
7 unchanged lines
- "208-240 VAC single phase"
- "Solar with battery (remote sites)"
- "Per electrical drawings"
default: "120 VAC single phase"
```
117 unchanged lines
label: Access Control Wiring Division
type: radio
+drawing_ref: "project responsibility matrix"
options:
- "This contract: conduit, boxes, pull strings, and operator terminations only"
- "This contract: complete operator wiring; access-control head end by others"
- "Per project responsibility matrix on drawings"
default: "This contract: conduit, boxes, pull strings, and operator terminations only"
```
195 unchanged lines
### Where automated gates are provided, the Contractor shall furnish, at a minimum, the manual-release keys or tools and any proprietary programming or limit-setting tool required for routine adjustment, and shall turn over the operator manufacturer's recommended spare-parts list.

View current revision