SynC · Topic
These are the standards in the SynC Standards library that cover AC Power. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Engineering analysis to calculate incident energy and the arc-flash boundary at every piece of electrical equipment where workers may interact with the equipment while it is energized or while it could be placed into an electrically safe work condition. Applies to AC systems from 208V through medium voltage, in commercial, institutional, industrial, and healthcare facilities. The study produces equipment labels, PPE specifications, and the documentation that supports an NFPA 70E-compliant electrical safety program.
Building wire and cable for power, lighting, branch circuit, and feeder applications rated 600V and below in commercial, institutional, and industrial buildings. Covers single conductors installed in raceways and cable tray, Type MC metal-clad cable, and Type AC armored cable; conductor materials (copper and aluminum); insulation types (THHN/THWN-2, XHHW-2, RHW-2, USE-2); ampacity selection and derating; voltage drop; color coding and conductor identification; splicing, connectors, and terminations; pulling and installation; insulation resistance testing; and field acceptance.
never for new adoptions — this standard has been merged into Panelboards, which carries its full content under the simple name.
Dead-front, free-standing low voltage distribution switchboards rated 600V and below, built to UL 891 and NEMA PB 2, with group-mounted molded-case or insulated-case circuit breakers (fixed-mounted or individually drawout). Covers service entrance and downstream distribution boards for commercial, institutional, and industrial facilities.
Calculation of available three-phase and line-to-ground short-circuit currents at every bus, transformer secondary, switchboard, panelboard, motor control center, and significant motor connection in a low- or medium-voltage power distribution system. The study output is used to specify equipment interrupting ratings, withstand ratings, and bus bracing, and to verify that installed and proposed equipment complies with NFPA 70 Article 110.9 and 110.10.
Receptacles, switches, and related wiring devices rated 125V through 250V and 60A and below for commercial, institutional, and light-industrial interior and exterior applications. Covers device grade and quality, NEMA receptacle configurations, GFCI and AFCI protection, tamper-resistant and weather-resistant devices, USB and specialty receptacles, snap switches, occupancy and vacancy sensors, wall plates and finishes, and floor and poke-through devices, including device testing and installation.