These are the standards in the SynC Standards library that cover Concrete. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Aggregate base course (ABC) for commercial, institutional, and industrial projects covering the placement, compaction, and quality control of crushed stone or processed graded aggregate used as the structural sub-base or base course beneath flexible (asphalt) and rigid (concrete) pavements, slabs-on-grade, building floor systems, exterior hardscape, equipment pads, and similar site improvements. Covers material classification and gradation, subgrade acceptance, geotextile separation where soft subgrades are encountered, lift placement, moisture conditioning, compaction, proof rolling, surface tolerances, and field testing. Intended to be read alongside the geotechnical investigation report, the civil grading drawings, and the structural or pavement section details, all of which govern design-specific values such as base thickness, target density, and material class.
Waterproofing of below-grade walls and slabs that retain earth and enclose interior space, where a groundwater investigation confirms a hydrostatic pressure condition or where the Owner requires waterproofing-level protection regardless of the groundwater finding. Covers the membrane families used below grade (self-adhering modified bituminous sheet, cold fluid-applied elastomeric, hot-applied rubberized asphalt, sodium bentonite geotextile composite, pre-applied bonded sheet, and surface-applied cementitious crystalline coating), positive-side, negative-side, and pre-applied blindside application, substrate preparation and priming, application temperature limits, laps and terminations, detailing at penetrations and joints, the protection course, the drainage layer bearing on the membrane, field watertightness verification, backfill against waterproofed surfaces, and warranties.
Structural cast-in-place concrete for buildings and structures — constituent materials, mixture proportioning and qualification, exposure-class durability requirements, ready-mixed production and delivery, placement and consolidation, hot- and cold-weather concreting, field testing, and evaluation and acceptance of the hardened concrete. Applies to footings, foundations, grade beams, mat foundations, below-grade walls, slabs on grade, elevated slabs and decks, columns, beams, and structural walls on commercial, institutional, and industrial projects.
Cast-in-place concrete equipment pads and housekeeping pads that receive mechanical, electrical, and plumbing equipment - generators, pad-mounted and dry-type transformers, switchgear and switchboard lineups, chillers, air handlers, condensing units, pumps, compressors, boilers, and similar equipment - whether the pad bears on grade, on an interior finished floor, on a structural slab, or on an exterior platform. Covers the decisions a pad standard actually owns: pad geometry and height, attachment to the supporting concrete, reinforcement method, cast-in and post-installed equipment anchorage, cast-in raceway and grounding provisions, liquid containment, surface finish and grout bed, isolation from adjacent construction, dimensional and anchorage tolerances, and the verification performed before concrete is placed and before equipment is set.
Seamless membranes built up in place from a liquid on concrete and masonry surfaces that enclose or protect occupied space: plaza and amenity decks, planters and landscaped areas, split-slab and topping-slab assemblies, between-slab and under-topping interior conditions, parking structure intermediate and roof levels with an exposed traffic-bearing membrane, and below-grade walls where a monolithic bonded membrane is selected instead of sheet. Covers hot fluid-applied rubberized asphalt and the cold liquid-applied chemistries (polyurethane, polymethyl methacrylate, polyurea, and polymer-modified asphalt emulsion), in both the buried configuration under a separate wearing course and the exposed configuration with an integral wearing surface, together with substrate preparation, primer, reinforcement, thickness control, protection course, drainage composite, root barrier, terminations, drains and penetrations, integrity testing, and warranty.
Mechanically ground, honed, and polished concrete floor finishes produced in place by progressive bonded-abrasive diamond processing of a structural or topping concrete slab, including chemical densification and optional coloring with dye or stain. Covers true bonded-abrasive polishing (full grind-hone-polish to a measured gloss and clarity), grind-and-seal finishes, and burnished guard finishes; aggregate exposure selection (cement fines, fine aggregate, coarse aggregate), gloss and clarity levels, densifier chemistry, joint and crack filling, slip resistance, abrasion resistance, and the coordination required to protect a finished slab that is also the building's structural floor.
Cast-in-place post-tensioned (PT) concrete for buildings and parking structures, where prestressing steel is tensioned after the concrete has cured and the force is anchored against the hardened member. Covers both dominant systems: unbonded single-strand tendons (greased-and-sheathed seven-wire strand, the standard system for elevated building floors and parking decks) and bonded multistrand tendons (strand bundled in ducts that are grouted after stressing, used for transfer girders, longer spans, and heavier post-tensioned beams). Addresses prestressing strand, anchorages and couplers and their qualification, sheathing and corrosion protection including encapsulated and electrically-isolated tendons for parking and aggressive exposure, tendon profile and placing tolerances, concrete strength at stressing, stressing operations and sequence, elongation measurement and acceptance, wedge seating, tendon cutting and pocket treatment, grouting of bonded tendons, and field quality control and records. Applicable to commercial, institutional, residential, and parking buildings.
Plant-fabricated precast and prestressed (pretensioned) concrete for buildings, including structural precast — columns, beams, spandrels, double-tees, hollow-core plank, solid and insulated wall panels, stair and landing units — and architectural precast cladding panels with specified exposed finishes. Covers concrete and release-strength requirements, pretensioned and conventionally reinforced production, connection hardware and embedded plates, architectural finishes (form liner, exposed aggregate, acid-etch, sandblast), PCI plant certification and quality control, product and erection tolerances, bearing pads, grouting, joint sealant coordination, erection, and patching. Applicable to commercial, institutional, industrial, parking, and multi-family buildings.
Fluid-applied, seamless resinous floor finishes installed over concrete in commercial, institutional, industrial, food and beverage, healthcare, laboratory, and cleanroom applications. Covers epoxy, polyurethane, cementitious urethane (urethane mortar), methyl methacrylate (MMA), and polyaspartic resin chemistries; thin-film coating, broadcast (sand, quartz, or vinyl flake) media, and trowel-applied mortar system types; slip resistance, chemical and thermal-shock resistance, abrasion, and electrostatic-dissipative and conductive (ESD) systems; concrete surface preparation and profiling, moisture testing and topical moisture mitigation, integral cove base, and seamless wall-to-floor detailing.
Cold-formed steel deck for floor and roof construction in commercial, institutional, industrial, and multi-family buildings. Covers composite floor deck (acting compositely with structural concrete topping), non-composite form deck (acting as a permanent stay-in-place form for a concrete slab), and roof deck profiles (Type B wide-rib, Type N deep-rib, Type A narrow-rib, Type F intermediate-rib). Addresses material grade and galvanized coating selection (G60, G90), deck profile and depth, gauge, attachment to supports (arc spot welds, powder-actuated fasteners, screws), side-lap fastening, diaphragm action, concrete fill for composite slabs, openings and reinforcement, accessories (closures, pour stops, ridge and valley plates), and field inspection.
The assembled unit masonry wall. Load-bearing walls, shear walls, non-load-bearing partitions, composite and multi-wythe walls, the masonry backup wythe of a cavity wall, and pilasters and piers, built from concrete masonry units alone or from concrete masonry units combined with clay brick. Covers the assembly design values (specified masonry compressive strength, the unit and grout strengths that follow from it, and the mortar type for each wall class), grouting extent and the cells that receive it, bar reinforcement and joint reinforcement, corrosion protection of embedded metal, wythe ties and intersecting-wall connections, bond beams and lintels, bond pattern, bedding, and joint profile, control and expansion joints in the assembly, the prescriptive seismic detailing the seismic design category invokes, bracing of walls under construction, tolerances tightened for exposed work, and the strength verification and special inspection program.