These are the standards in the SynC Standards library that cover Fire Barriers. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Thermal insulation installed in the opaque building envelope of commercial, institutional, multifamily, and residential buildings, covering above-grade wall cavity and continuous insulation, low-slope and steep-slope roof and attic insulation, floors and ceilings over unconditioned space, crawl space enclosures, below-grade foundation walls, and under-slab and slab-edge insulation. Covers all principal insulation forms sold in the North American market: mineral fiber batt, blanket, and board; loose-fill and dense-packed cellulose, fiberglass, and mineral wool; extruded, expanded, and graphite-enhanced polystyrene board; polyisocyanurate board; cellular glass; wood fiber and cellulosic board; spray-applied polyurethane foam; and reflective insulation and radiant barriers. Also covers the thermal resistance basis used to demonstrate energy code compliance, surface burning and foam plastic fire requirements, vapor retarder classification and placement, air barrier coordination, thermal bridge mitigation, and field verification before assemblies are concealed.
Dedicated indoor electrical rooms and closets housing service entrance equipment, distribution switchgear, switchboards, panelboards, motor control centers, dry-type transformers, automatic transfer switches, indoor standby generators or paralleling switchgear, DC battery systems, and the associated grounding, raceway, and control infrastructure for commercial, institutional, healthcare, higher-education, data center, and industrial buildings. Covers working clearances, dedicated electrical space, headroom, door and egress arrangement, fire-resistance ratings of enclosing assemblies, ventilation and cooling for equipment heat rejection, room illumination, convenience power, drainage and plumbing restrictions, security and access control, equipment anchorage, finishes, and signage.
Gypsum board partitions, wall assemblies, and ceiling systems for commercial, institutional, and multi-family residential buildings. Covers interior non-load-bearing steel-framed partitions, shaft walls, chase walls, area separation walls, furring and freestanding wall assemblies, and suspended or directly attached gypsum board ceiling systems. Includes fire-resistance-rated and sound-rated assemblies, all board types, steel framing and furring, finish levels, joint treatment, accessories, and control joints.