These are the standards in the SynC Standards library that cover Hydronics. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Gas-fired and oil-fired hydronic (hot water) and low-pressure steam heating boilers for commercial, institutional, and industrial HVAC space-heating service. Covers condensing and non-condensing units, fire-tube and water-tube configurations, single and modular (multiple-boiler) plants, and packaged factory-assembled units from approximately 300 MBH input through the upper limit of low-pressure heating boiler service (15 psig steam; 160 psig and 250°F hot water). Addresses natural gas, propane, No. 2 fuel oil, and dual-fuel firing, with modulating and staged combustion controls and building automation system integration.
Rotodynamic (centrifugal) pumps that circulate water and water-glycol solutions for building heating, cooling, and heat-rejection service. Covers closed-loop heating hot water and chilled water pumps, open-loop condenser water pumps serving cooling towers and fluid coolers, condenser loops serving water-source heat pumps, and the vertical turbine pumps used where the supply level sits below the pump. Addresses the pump end, the driving motor, the baseplate or frame, the coupling, shaft sealing, vibration isolation, factory and field acceptance testing, and the coordination items that decide whether the installed pump reaches its certified curve.
The ongoing chemical and physical water treatment program for HVAC water systems in commercial, institutional, and industrial buildings. Covers closed hydronic loops (heating hot water, chilled water, dual-temperature, water-source and ground-source heat pump loops, and inhibited-glycol loops), open recirculating condenser water systems served by cooling towers and evaporative condensers, and steam and condensate systems at or below 150 psig. Addresses make-up water characterization, corrosion and scale inhibitor chemistry, biocide programs, cycles of concentration and bleed control, chemical feed and controller equipment, side-stream filtration, sample ports and routine monitoring, corrosion coupon reading, the Legionella risk-management documentation required under ANSI/ASHRAE 188, the service contract that sustains the program, and seasonal lay-up.
Closed-loop hydronic distribution piping for heating hot water (HHW), chilled water (CHW), dual-temperature water (DTW), and condenser water (CW) in commercial, institutional, and industrial buildings, within the ASME B31.9 building-services envelope (up to 160 psig and 250°F). Covers pipe material and wall selection by service and size band, joining methods, fittings and flanges, dissimilar-metal isolation, delivery and storage, piping installation and routing discipline, the interfaces to supports, expansion compensation, valves, specialties, insulation, identification, and system cleaning, and the structural pressure test that proves the installed system.