Arc Flash
These are the standards in SynC Standards that cover Arc Flash. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide, with the standards each is verified against. All of it is written and maintained by SynC, free to read without an account, and published under CC BY 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Standards
- Arc-Flash Study
The arc-flash study for a project's electrical power distribution system: the incident energy and the arc-flash boundary at every bus a worker examines, adjusts, services, or maintains while it is energized, on AC systems from 208 V through 38 kV with utility, generator, inverter-based, and paralleled sources, and on the DC side of battery, energy storage, and photovoltaic equipment where the project includes it. Covers who performs the study and when it is issued, the IEEE 1584-2018 method and the methods applied outside its range, the buses studied, the source operating cases and the maintenance-mode cases, the arcing current variation, the clearing time taken from the accepted coordination settings, the arc-flash input data the system model does not already carry (electrode configuration, enclosure dimensions, bus gap, working distance), the content of the arc-flash label, the PPE arc rating the facility's safety program consumes, the mitigation recommendations, the report, and the five-year review and the events that call for a re-study.
- Electrical Equipment Labels
The labels, nameplates, directories and signs applied in the field to the enclosures of electrical equipment rated 1000 V and below, and of the medium-voltage equipment on the same project: switchgear, switchboards, panelboards, motor control centers, transformers, transfer switches, generators, drives, disconnects, starters, busway, meter enclosures and control enclosures. Covers the equipment identification nameplate with its designation and source, the nameplates on each device and compartment, the circuit directory, the warning and danger signs NFPA 70 requires on equipment for voltage, multiple sources, disconnect location, back-fed devices, series ratings and ungrounded systems, the arc-flash warning label as a product and its installation, the available fault current marking, service equipment signs, the marking of emergency and standby system equipment, nameplate material, colors, character heights and attachment, the ANSI Z535.4 format of safety signs, installation, warranty and spare stock.
- Industrial Control Panels
Factory-fabricated industrial control panels and enclosures that house instrumentation and controls (I&C) equipment for industrial, process, and water/wastewater (WTP/WWTP) facilities. Covers UL 508A listed control panels and enclosures housing programmable logic controllers, remote I/O, control relays, power supplies, network switches, and operator interface devices, rated 1000V and below. Addresses enclosure type rating selection (UL/NEMA Type 1, 3R, 4, 4X, 12), short-circuit current rating (SCCR) determination per UL 508A Supplement SB and NEC Article 409, enclosure sizing and component layout, internal power distribution and control power transformers, power-versus-signal wiring segregation, wire and terminal-block identification, thermal management, grounding and bonding, nameplates, and arc-flash labeling.
- Medium Voltage Switchgear
Metal-clad medium-voltage switchgear rated above 1 kV through 38 kV using drawout vacuum or SF6 circuit breakers, built to IEEE C37.20.2 and the ANSI/IEEE C37.04 / C37.06 / C37.09 series, for utility-customer substations, large commercial campuses, healthcare and higher-education central plants, data centers, and industrial facilities. Covers 5 kV, 15 kV, 27 kV, and 38 kV voltage classes, indoor and outdoor walk-in (protected aisle) configurations, arc-resistant ratings per IEEE C37.20.7, multifunction microprocessor protective relays, and optional IEC 61850 station bus communications.