SynC · Topic
Motor Control Centers
These are the standards in SynC Standards that cover Motor Control Centers. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide, with the standards each is verified against. All of it is written and maintained by SynC, free to read without an account, and published under CC BY 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Standards
- Electrical Equipment Labels
The labels, nameplates, directories and signs applied in the field to the enclosures of electrical equipment rated 1000 V and below, and of the medium-voltage equipment on the same project: switchgear, switchboards, panelboards, motor control centers, transformers, transfer switches, generators, drives, disconnects, starters, busway, meter enclosures and control enclosures. Covers the equipment identification nameplate with its designation and source, the nameplates on each device and compartment, the circuit directory, the warning and danger signs NFPA 70 requires on equipment for voltage, multiple sources, disconnect location, back-fed devices, series ratings and ungrounded systems, the arc-flash warning label as a product and its installation, the available fault current marking, service equipment signs, the marking of emergency and standby system equipment, nameplate material, colors, character heights and attachment, the ANSI Z535.4 format of safety signs, installation, warranty and spare stock.
- Electrical Rooms
The dedicated indoor electrical room and the electrical closet as a space: the room that houses service equipment, switchgear, switchboards, panelboards, motor control centers, dry-type transformers, transfer switches, drives, UPS modules, control-power batteries and the open or paralleling generator sets installed indoors. Covers the working space and the dedicated electrical space the adopted electrical code requires about the equipment, headroom, the number of entrances, door swing, clear opening and panic hardware, locking and free egress, the fire-resistance rating of the enclosing construction where a code sets one, the exclusion of piping and ductwork foreign to the electrical installation, water protection at the door and on the floor, the heat-release basis and the ventilation or cooling performance the room has to deliver, the temperature and humidity limits taken from the equipment ratings, illumination and emergency illumination of the working space, the convenience receptacle, housekeeping pad provision, floor finish, the room ground bar, the signs on the room door, the coordination drawing that proves every clearance before the room is framed, and the field verification before the room is closed in and before equipment is set.
- Motor Control Centers
Factory-assembled, floor-standing low-voltage motor control centers rated 600 V and below, listed to UL 845 and built to NEMA ICS 18, in which combination motor starter units, reduced-voltage starter units, variable frequency drive units, feeder units, control power units, and metering units plug onto a common vertical bus fed from a common horizontal bus. Covers the assembly ratings, the enclosure and structure, the bus, the wiring class and type, arc-flash mitigation, the unit construction and the devices inside each unit, communications, identification, factory and field testing, installation, warranty, and spares, for indoor and outdoor installations.