title: Architectural Wood Trim and Paneling
310 unchanged lines
label: Lumber and Veneer Cut
type: select
drawing_ref: true
+drawing_ref: "finish schedule"
options:
- "Plain-sawn / flat-sawn — cathedral grain, economical (standard)"
- "Quarter-sawn — straight grain, ray fleck in oak, more stable"
- "Rift-sawn — tight uniform straight grain, no fleck (most refined)"
- "Mixed / as selected per location on finish schedule"
default: "Plain-sawn / flat-sawn — cathedral grain, economical (standard)"
```
529 unchanged lines
#### The most common cause of in-service paneling and trim failure is not a defect in the woodwork but a building allowed to swing far outside the humidity range the woodwork was fabricated for, which drives the cupping, splitting, and open joints that the floating-panel and movement provisions can only partly absorb. {note}