These are the standards in the SynC Standards library that cover Anchorage. Each one is a complete, plain-language specification: the scope it applies to, the requirements that govern it, and a structured equipment datasheet listing the values a project has to decide — ratings, materials, setpoints, and the standards each is verified against. All of it is free to read without an account and published under CC BY-SA 4.0.
A standard usually carries several topics, so most of the entries below also appear under neighbouring subjects. The topics each one carries are listed on its own page.
Non-load-bearing extruded aluminum framing systems glazed with monolithic or insulating glass, and the aluminum stile-and-rail swing entrance doors integrated with them, at building perimeters and interior partitions. Covers framing depth, sightline, joinery, glazing pocket position, and thermal barrier construction; glass lite construction, insulating glass unit make-up, edge seal, and low-emissivity coatings; dry, wet, and structural silicone glazing methods; air infiltration, water penetration, structural wind load, thermal transmittance, solar heat gain, condensation, acoustic, windborne debris, and inter-story drift performance; entrance door leaf proportions, construction, hardware, thresholds, and weatherseals; anodic and organic finishes; perimeter anchorage, sill water management, and air and water control layer continuity; laboratory and field testing; installation, cleaning, protection, and warranty.
Exterior and site lighting for commercial, institutional, industrial, and campus projects, including area and roadway luminaires, parking-lot and parking-structure luminaires, floodlights, wall-pack luminaires, bollards, and their supporting poles, foundations, and lighting controls. Covers luminaire photometric performance, light-pollution and dark-sky control, LED drivers and electrical requirements, pole and support structures, foundations and anchorage, photocontrol and scheduling controls, surge protection, and corrosion-resistant finishes for outdoor service.
Aluminum-framed glazed curtain wall acting as the primary non-load-bearing exterior enclosure of a building — stick-built, semi-unitized, and unitized systems that span vertically across one or more stories and hang from the building frame at discrete anchors. Covers the assembly method, the water management principle and internal drainage, mechanically captured and structurally silicone-glazed retention, framing member sizing and thermal barriers, the vision and spandrel glazing selection tree the framing delivers, aluminum finishes, air and water penetration resistance, thermal transmittance and condensation resistance, acoustic performance, wind pressure and deflection criteria, thermal and seismic movement accommodation, wind-borne debris impact resistance, perimeter fire containment at the floor edge, anchorage and movement joints, perimeter air and water barrier continuity, fabrication, mockups, erection, and field water and air testing.
Factory-fabricated sheet-steel lockers and their doors, latching, locking, trim, interior equipment, and anchorage, in knocked-down or welded construction, for school corridors, athletic and team rooms, employee and industrial change rooms, public recreation, and day-use storage. Covers substrate selection and corrosion protection, component sheet thickness, tier and opening configuration, door ventilation, latching and locking including electronic locks, powder-coat finish performance, tops, bases and closure trim, accessible lockers under the ADA Standards and ICC A117.1, and floor, wall, and seismic anchorage.
Shop-fabricated miscellaneous steel fabrications that are not part of the primary structural frame and are not stairs or railings — fixed steel ladders with cages or ladder safety systems, ship's ladders, steel pipe and tube bollards (fixed, removable, and structural impact protection), loose steel lintels and masonry shelf angles, steel edge angles and nosings, loose embedded steel furnished for casting into concrete by others (embed plates, weld plates, anchor channels), steel bar gratings and floor (checkered) plate covers and frames, trench and pit frames and covers, equipment supports and rooftop dunnage and steel framing that is not part of the building frame, guard rails and wheel guards for equipment protection, and other miscellaneous steel framing. Covers materials (carbon steel, structural tubing, pipe, stainless where used), hot-dip galvanizing and field repair, shop priming and surface preparation, welding, mechanical fasteners and anchors, and shop and erection tolerances. Applicable to commercial, institutional, industrial, and multi-family buildings.