SynC · Library
SynC Standards
Standards
Electrical
Power Distribution Equipment
(22)
- Automatic Transfer Switches
Automatic transfer switches rated 1000 V and below, listed to UL 1008, that move a load between a normal source and an alternate source without operator action. Covers the switching mechanism, transition type, bypass-isolation construction, neutral treatment, the controller and its sensing, time delays, exerciser, load management and communications provisions, ratings including withstand and closing and short-time ratings, service-entrance construction, enclosures, identification, factory and field testing, installation, warranty, and spare parts, for switches serving emergency, legally required standby, optional standby, critical operations, and health care essential electrical system loads.
- Combination and Manual Motor Starters
Individually enclosed motor starters rated 600 V and below that control and protect one motor on its own branch circuit outside a motor control center. Covers combination starters that assemble a disconnecting means, branch-circuit short-circuit and ground-fault protection, a contactor, and an overload relay in one listed enclosure, in full-voltage non-reversing, reversing, two-speed, and reduced-voltage configurations, and manual motor starters that combine a hand-operated contact mechanism with an overload relay. Covers the ratings, the branch-circuit protective device, the contactor, the overload relay, control power, pilot devices and remote interfaces, the enclosure, identification, factory and field testing, installation, warranty, and spares, for indoor and outdoor installations.
- DC Battery Systems
Stationary battery systems with chargers providing 24, 48, 125, or 250 VDC control power to switchgear protective relays, breakers, transfer switches, communications, generator starting, emergency lighting inverters, and other critical control loads in substations, generating stations, industrial facilities, and electrical rooms. Covers vented lead-acid (VLA), valve-regulated lead-acid (VRLA), and vented nickel-cadmium (Ni-Cd) chemistries; their chargers; DC distribution; battery monitoring; and the battery room or cabinet. Cross-references the loads they serve (see Low Voltage Switchgear and Medium Voltage Switchgear) and grounding of the DC system (see Grounding And Bonding).
- Distribution Transformers (Superseded)
never for new adoptions — this standard has been split and superseded. For dry-type transformers rated 600 V and below use Low Voltage Dry Type Transformers; for transformers with a primary above 600 V (liquid-immersed pad-mounted and MV dry-type) use Medium Voltage Transformers.
- Electrical Service Entrance
The electrical service to a building or structure at 1000 V and below, from the serving utility's point of delivery through the service disconnecting means. Covers coordination with the serving utility and the utility's published service requirements as a project fact, the overhead drop and underground lateral arrangements, the routing of the service-entrance conductors and the NFPA 70 Article 230 rules that apply to them, service masts and weatherheads, meter sockets, current transformer cabinets and the metering enclosures the utility requires, the number, grouping, location, and marking of the service disconnects, the available fault current marking, the surge protective device the service requires, ground-fault protection of equipment at the service, the emergency disconnect, field testing of the service before energization, installation, warranty, and spares, for new services and service upgrades on single-phase and three-phase systems.
- Emergency and Standby Power Systems
System-level standard establishing the classification, source selection, load assignment, transfer scheme, overcurrent coordination, and acceptance testing for a building's emergency and standby power system, in accordance with NFPA 70 Articles 700 (Emergency Systems), 701 (Legally Required Standby), 702 (Optional Standby), and 708 (Critical Operations Power Systems), and NFPA 110 and NFPA 111. Use this standard to define what the system must do as a whole — which loads are emergency vs. standby, what alternate source serves them, how fast they transfer, and how they are commissioned and maintained. Component-level requirements are deferred to the equipment standards for the engine-generator set (see Generators), the automatic transfer switches (see Automatic Transfer Switches), and the stored-energy sources (see Battery Energy Storage Systems).
- Enclosed Switches and Disconnects
Individually enclosed disconnecting means rated 1000 V and below, furnished as separate products rather than as part of an assembly: fusible and non-fusible safety switches listed to UL 98 in heavy-duty and general-duty construction, enclosed molded-case circuit breakers and molded-case switches listed to UL 489 and applied as stand-alone disconnects, manual motor controllers listed to UL 508 and marked suitable as motor disconnects, double-throw safety switches and manual transfer switches, and the fuses installed in them, serving feeders, motors, air-conditioning and refrigeration equipment, elevators, electric vehicle supply equipment, and other utilization equipment. Covers the device family and duty class, the overcurrent provision, the voltage, ampere, horsepower, and short-circuit ratings, poles and neutral, fuse class and clips, the operating handle, lockout and door interlock, accessories, the enclosure, identification, factory and field testing, installation, warranty, and spares, for indoor and outdoor locations.
- Engine Generators
Packaged stationary engine-generator sets rated 1000 V and below, listed to UL 2200, furnished as the alternate source for emergency, legally required standby, optional standby, and critical operations loads, and sets the project applies as a prime or continuous source. Covers the engine and its fuel requirements by fuel type, the alternator and its excitation, the governor and voltage regulator, the set-mounted controller and the remote annunciator, the main line circuit breaker and the neutral bonding at the set, the cooling system, the fuel system on the skid including the sub-base tank, the exhaust silencer and aftertreatment, the enclosure and its sound attenuation, the starting batteries and charger, vibration isolation and seismic certification, factory and field testing, installation, warranty, and spare parts.
- Generator Paralleling Switchgear
Paralleling switchgear rated 1000 V and below that connects two or more engine-generator sets to a common bus, synchronizes each set to the bus, shares the real and reactive load among them, adds and sheds load in priority order, protects each set and the bus, and distributes the paralleled source to the transfer switches or the emergency distribution. Covers the construction basis as a switchboard listed to UL 891 or as metal-enclosed switchgear listed to UL 1558, the generator breaker sections, the master and per-set control sections, the bus tie and distribution sections, the bus and its ratings, the control architecture, synchronizing, load sharing, load add and load shed, the generator protective functions, open-transition, closed-transition, and extended parallel operation with the utility, the control power source, the operator interface and annunciation, communications, the maintenance bypass arrangement, arc-flash mitigation, identification, factory integrated testing with the sets, field acceptance tests, installation, warranty, and spares.
- Healthcare Essential Electrical Systems
The essential electrical system of a health care facility under NFPA 70 Article 517 and NFPA 99: hospitals, nursing homes, limited care facilities, ambulatory health care occupancies, and any other facility with patient care spaces. Covers the risk categories of the spaces served and the system type that follows from them, the life safety, critical, and equipment branches and the loads assigned to each, the alternate source performance the system requires, the number and arrangement of the transfer switches that serve the branches, the separation and mechanical protection of the branch wiring, the branch circuits and receptacles of patient bed locations and their identification, the second level of ground-fault protection, isolated power systems for wet procedure locations, the coordination requirement specific to the system, the documentation the Authority Having Jurisdiction and the accrediting bodies survey, and the acceptance and periodic testing of the system as a whole.
- Low Voltage Switchboards
Dead-front, floor-standing distribution switchboards rated 1000 V and below, listed to UL 891 and built to NEMA PB 2, in which molded-case or insulated-case circuit breakers, fusible switches, or bolted-pressure switches are group-mounted or individually mounted on a common bus, whether installed as service equipment or downstream of a transformer, switchgear, or another switchboard. Covers the ratings, the interrupting rating basis, the main and feeder devices and their trip units, the bus, the structure and enclosure, arc-flash mitigation, the service entrance, surge protection, metering and communications provisions built into the assembly, identification, factory and field testing, installation, warranty, and spares, for three-phase and single-phase AC systems in indoor and outdoor locations.
- Low Voltage Switchgear
Metal-enclosed low-voltage power circuit breaker switchgear rated 1000 V and below, listed to UL 1558 and built to IEEE C37.20.1, in which drawout low-voltage power circuit breakers built to IEEE C37.13 are individually mounted in grounded metal compartments on a common bus, whether installed as service equipment, as the secondary of a transformer, or downstream of other distribution equipment. Covers the ratings and the short-time basis, the breakers and their drawout mechanisms, operation, trip units, and accessories, ground-fault protection, arc energy reduction, control power and control wiring, the protective relays, instrument transformers, metering, surge protection, and communications provisions built into the assembly, the bus, the structure and enclosure, compartmentalization and arc-resistant construction, identification, factory and field testing, installation, warranty, spares, and breaker handling equipment, for three-phase and single-phase AC systems in indoor and outdoor locations, including walk-in and non-walk-in outdoor housings.
- Low-Voltage Dry-Type Transformers
Dry-type transformers with both windings rated 1000 V and below, listed to UL 1561 and built to IEEE C57.12.01 and NEMA ST 20, single-phase and three-phase, purchased on their own to step a building's distribution voltage down to a utilization voltage or up to a higher one, including the specialty units built on the same construction: K-factor rated, harmonic-mitigating, drive-isolation, and shielded isolation transformers. Covers the ventilated, encapsulated, and cast-coil constructions, efficiency under 10 CFR Part 431, winding material, insulation system and temperature rise, K-factor and harmonic treatment, electrostatic shield, taps, impedance, sound level, enclosure type, terminations and the secondary neutral terminal, accessories, vibration isolation, seismic certification, factory and field tests, mounting and installation, warranty, and spares.
- Medium Voltage Switchgear
Metal-clad medium-voltage switchgear rated above 1 kV through 38 kV using drawout vacuum or SF6 circuit breakers, built to IEEE C37.20.2 and the ANSI/IEEE C37.04 / C37.06 / C37.09 series, for utility-customer substations, large commercial campuses, healthcare and higher-education central plants, data centers, and industrial facilities. Covers 5 kV, 15 kV, 27 kV, and 38 kV voltage classes, indoor and outdoor walk-in (protected aisle) configurations, arc-resistant ratings per IEEE C37.20.7, multifunction microprocessor protective relays, and optional IEC 61850 station bus communications.
- Medium-Voltage Distribution Transformers
Customer-owned three-phase distribution transformers with a primary winding rated above 600 V through 34.5 kV and a rating of 10 MVA and smaller, stepping a utility or premises medium-voltage supply down to a building's utilization voltage or to a lower medium voltage. Covers liquid-immersed and dry-type units in pad-mounted compartmental and substation-type construction, including ratings, insulation levels, taps, impedance, losses, sound, the insulating liquid and its preservation, dry-type encapsulation and insulation systems, terminations, primary switching and fusing, surge arresters, accessories, factory and field testing, and installation on a pad, in a vault, or in an electrical room.
- Medium-Voltage Metal-Enclosed Bus
Metal-enclosed bus built to IEEE C37.23, in nonsegregated-phase, segregated-phase, and self-cooled isolated-phase construction, in the 600 V class and the 5 kV through 38 kV classes, used to connect switchgear to a transformer, a transformer to switchgear, a generator to its switchgear, one switchgear lineup to another, or a drive to its supply, where the current or the voltage puts the connection beyond what cable or UL 857 busway serves. Covers the bus run as one assembly: the type, the voltage class and insulation level, the continuous and short-circuit withstand ratings, the conductors, their plating, insulation, and support insulators, the bolted joints, the enclosure and its material, ventilation, enclosure type, and outdoor provisions, the fittings, the expansion and penetration provisions, the termination flanges and flexible connectors at the equipment, the supports, enclosure grounding continuity, identification, factory and field testing, installation, warranty, and spares, for three-phase AC systems in indoor and outdoor locations.
- Medium-Voltage Variable Frequency Drives
Separately procured variable frequency drives for three-phase motors rated above 600 V, in the 2.3 kV, 4.16 kV, 6.6 kV, and 13.8 kV classes, driving process pumps, blowers, compressors, fans, and conveyors in water, wastewater, industrial, and power facilities. Covers the drive topology and its input transformer, harmonic performance at the point of common coupling, the output side and its effect on the motor and the cable, cooling, the enclosure, input isolation and fusing, the bypass, motor protection, control power, communications, efficiency, sound, altitude and ambient derating, factory tests, field startup, training, the field acceptance tests this class receives, identification, warranty, and spares.
- Metal-Enclosed Interrupter Switchgear
Stand-alone metal-enclosed interrupter switchgear built to IEEE C37.20.3, rated above 1 kV through 38 kV, in which gang-operated load-interrupter switches, with or without power fuses, are the switching and protective devices, furnished as a medium-voltage service entrance, a primary-selective or loop lineup, a feeder lineup, or the primary switching ahead of separately mounted transformers, indoors or outdoors. Covers the arrangement and the automatic source transfer on a two-source lineup, the ratings, the switches and their mechanisms and operators, the power fuses, the key interlocks and grounding switches, the bus and its insulation, arc-resistant construction, the instrument transformers and the metering section, surge arresters, the cable compartments and the space the lineup provides for terminations, the enclosure, identification, factory and field testing, installation, warranty, and spares.
- Motor Control Centers
Factory-assembled, floor-standing low-voltage motor control centers rated 600 V and below, listed to UL 845 and built to NEMA ICS 18, in which combination motor starter units, reduced-voltage starter units, variable frequency drive units, feeder units, control power units, and metering units plug onto a common vertical bus fed from a common horizontal bus. Covers the assembly ratings, the enclosure and structure, the bus, the wiring class and type, arc-flash mitigation, the unit construction and the devices inside each unit, communications, identification, factory and field testing, installation, warranty, and spares, for indoor and outdoor installations.
- Secondary Unit Substations
Factory-coordinated secondary unit substations within the scope of IEEE C37.121, in which a medium-voltage primary section (an incoming air terminal chamber, a load-interrupter switch with or without power fuses, or metal-clad circuit breaker switchgear), a three-phase step-down transformer (liquid-immersed or dry-type), and a secondary section of low-voltage switchgear, switchboard, or motor control center construction are close-coupled into one assembly under one manufacturer of record. Covers what only the assembly decides: the single-ended or double-ended arrangement and the tie transfer scheme, the ratings coordinated across the three sections, the throats and transitions between them, the assembly enclosure, the protective-device actions wired between sections, factory testing of the assembled lineup, field acceptance of the assembly, installation, warranty, and spares. Each section's own construction is invoked by reference to the standard that governs that product.
- Service and Feeder Conductors
The service conductors of a building or structure at 1000 V and below, from the service point to the service disconnecting means, complete: the conductor or cable product, its material, its sizing to the calculated load under NFPA 70 Articles 220 and 230, its termination temperature basis, its line-side splices and terminations, and its acceptance tests; and the application rules that apply to feeders over and above the conductor product: feeder sizing to the calculated load under NFPA 70 Articles 215 and 220, feeder protection at the conductor ampacity, parallel conductor sets and their raceway arrangement, the sizing of the feeder neutral for nonlinear load, the feeder voltage-drop criterion, feeder taps and transformer secondary conductors under NFPA 70 240.21, feeders to a separate structure and to a crane runway disconnect, and the acceptance tests a feeder receives beyond those of the conductor product. Applies to commercial, institutional, industrial, and water and wastewater facilities, new services and feeders and the upgrade of existing ones.
- Uninterruptible Power Supply Systems
Static (solid-state) uninterruptible power supply (UPS) systems that protect critical AC electrical loads — data processing and IT equipment, network and communications gear, life-safety and process controls, medical equipment, and other loads that cannot tolerate a power interruption or a sag — from utility disturbances, sags, surges, and outages. Covers single-phase and three-phase units of small (point-of-use), medium, and large (data center and facility) ratings; topology selection per IEC 62040-3 (double-conversion VFI, line-interactive VI, standby VFD); transformer-free and transformer-based designs; VRLA and lithium-ion battery energy storage with runtime sizing per IEEE 1184; internal static bypass and external maintenance (wraparound) bypass; redundancy from a single module through N+1, parallel, and dual-bus/2N; input harmonics and output performance for nonlinear loads; efficiency and energy-saver/eco modes; monitoring, communications, and emergency power off; seismic anchorage; and the room and code requirements the unit imposes.
Power Studies
(4)
- Arc-Flash Study
The arc-flash study for a project's electrical power distribution system: the incident energy and the arc-flash boundary at every bus a worker examines, adjusts, services, or maintains while it is energized, on AC systems from 208 V through 38 kV with utility, generator, inverter-based, and paralleled sources, and on the DC side of battery, energy storage, and photovoltaic equipment where the project includes it. Covers who performs the study and when it is issued, the IEEE 1584-2018 method and the methods applied outside its range, the buses studied, the source operating cases and the maintenance-mode cases, the arcing current variation, the clearing time taken from the accepted coordination settings, the arc-flash input data the system model does not already carry (electrode configuration, enclosure dimensions, bus gap, working distance), the content of the arc-flash label, the PPE arc rating the facility's safety program consumes, the mitigation recommendations, the report, and the five-year review and the events that call for a re-study.
- Electrical Acceptance Testing
The field acceptance test program applied to new electrical power distribution equipment after installation and before it is first energized, on systems rated 1000 V and below through 38 kV. Covers who performs the tests and how the firm and its technicians are qualified, the test instruments, the electrical safety basis for the work, the equipment classes and the optional tests within the program, the test plan and the hold points that release energization, the acceptance criteria that every equipment standard's field tests are judged against (insulation resistance, bolted connections, transformer ratio and winding checks, trip unit and relay verification, dielectric tests, instrument transformers), the post-energization infrared survey, deficiency resolution and retesting, and the compiled test report. Each equipment standard names the tests its equipment receives and invokes this standard for the method, the criteria, the tester, and the report.
- Protective Device Coordination Study
The time-current coordination study for a project's electrical power distribution system, from the utility's protective device at the point of delivery through every overcurrent protective device within the extent the datasheet selects, on AC systems rated 1000 V and below through 38 kV with utility, generator, inverter-based, and paralleled sources. Covers who performs the study and when it is delivered, the degree of coordination applied to normal distribution and the circuits on which NFPA 70 620.62, 645.27, 700.32, 701.32, 708.54, and 517.31(G) require selective coordination, the coordination time intervals and band separations, the curves of the utility device, transformers, motors, conductors, generators, and inverter-based sources that bound every setting, the coordination of ground-fault protection including the two levels NFPA 70 517.17 requires, the recommended setting of every trip unit, relay, fuse, and overload relay, the trade-off between selectivity and incident energy, the coordination deficiencies and who accepts them, the settings record handed to the field, the report, and the events that call for a re-study.
- Short-Circuit Study
The short-circuit study for a project's electrical power distribution system, from the utility point of delivery through every point at which an interrupting rating, a close-and-latch rating, a short-time withstand rating, a bus bracing rating, or a marked short-circuit current rating is confirmed, on AC systems rated 1000 V and below through 38 kV with utility, generator, inverter-based, and paralleled sources. Covers who performs the study and when it is delivered, the calculation method and the duty networks, the fault types and the maximum and minimum cases, the system model and the data it is built from (the utility's available fault current and X/R, transformer impedances, conductor impedances and lengths, motor and generator contribution, inverter-based sources, and the survey of existing equipment on a renovation), the source operating cases, the equipment duty evaluation, the treatment of series-rated combinations, the available fault current and date that NFPA 70 110.24 requires at the service equipment, the report and the model handed to the coordination and arc-flash studies, and the events that call for a re-study.
Lighting
(4)
- Emergency and Egress Lighting
The illumination of the means of egress under normal power, the emergency illumination that replaces it when normal power fails, exit signs, and luminous egress path markings, in new construction and renovation of commercial, institutional, assembly, industrial, and multi-occupancy buildings. Covers the code-required illumination levels and duration, the photometric demonstration of compliance, the choice of emergency power source strategy for egress illumination, self-contained unit equipment, emergency battery packs in architectural luminaires as they serve the egress design, central inverter systems, generator-backed emergency lighting circuits and their battery bridging, exit sign type, power source, legend, and construction, photoluminescent and self-luminous signs, luminous egress path marking, periodic testing and monitoring provisions, the wiring independence NFPA 70 Article 700 requires, acceptance testing, warranty, and spares.
- Exterior and Site Lighting
Exterior and site lighting for commercial, institutional, industrial, and campus projects, including area and roadway luminaires, parking-lot and parking-structure luminaires, floodlights, wall-pack luminaires, bollards, and their supporting poles, foundations, and lighting controls. Covers luminaire photometric performance, light-pollution and dark-sky control, LED drivers and electrical requirements, pole and support structures, foundations and anchorage, photocontrol and scheduling controls, surge protection, and corrosion-resistant finishes for outdoor service.
- Interior Lighting Fixtures (Luminaires)
Permanently installed interior luminaires for commercial, institutional, industrial, multifamily, and mixed-use buildings: recessed troffers and panels, downlights, recessed and surface linear luminaires, pendants, wall-mounted and cove luminaires, high-bay and low-bay luminaires, vapor-tight and washdown luminaires, and the luminaires in refrigerated and unconditioned interior spaces. Covers the LED light source, chromaticity and its tolerance, color rendition, efficacy, lumen maintenance and rated life, photometric measurement, glare control and optics, the LED driver and its input voltage, power quality and surge immunity, the dimming input and its response to the control signal, the lowest dimming level, the dimming curve, color tuning, flicker, the integral emergency battery driver as a component of the luminaire, housings, insulation-contact and air-tight recessed housings, location listings, mounting, support, the seismic attachment of recessed and pendant luminaires in suspended ceilings, the luminaire schedule as the record of each type, field testing, warranty, and spares.
- Lighting Controls
The interior lighting control system of a commercial, institutional, or industrial building: the occupancy and vacancy sensors, daylight sensors, time schedules, manual control stations, relay panels, lighting contactors, lighting-control panelboards, room controllers, networked and luminaire-level control systems, and the management software that together decide when each luminaire is on, off, or at an intermediate level. Covers the control architecture and its network, the control signal and protocol delivered to the luminaire driver and the minimum light level the system commands, occupancy and vacancy sensing, daylight-responsive control, time scheduling and override, manual control, branch-circuit switching equipment, automatic receptacle control, demand-responsive control, the interfaces to the building automation system, motorized shades, and other building systems, the UL 924 override device that returns a controlled egress luminaire to full output, the low-voltage control wiring, the documented sequences of operation, startup, programming, functional testing, training, warranty, and spares.
- Access Control Systems
Electronic access control systems for managing pedestrian entry into commercial, institutional, and industrial buildings. Covers system architecture (standalone, networked, and cloud-managed), door controllers and panels, credential readers and credentials, electrified door hardware coordination, request-to-exit devices, door position switches, low-voltage power supplies with battery backup, controller and reader cabling, head-end software, user management and audit, fire alarm release interface, cybersecurity, and acceptance testing for swinging pedestrian doors.
- Battery Energy Storage Systems
Stationary battery energy storage systems at the building and campus scale, listed to UL 9540 and installed under NFPA 855 and the adopted fire code, on commercial, institutional, industrial, and multifamily projects and on campus and microgrid sites: lithium-ion, sodium-ion, lead-acid, and flow chemistries, in a battery room, a dedicated building, a factory-assembled outdoor cabinet, a walk-in container, or on a roof, applied to peak shaving, time-of-use shifting, backup of designated loads, photovoltaic firming, utility programs, and islanded operation. Covers the listing and the UL 9540A test data and what they decide, the chemistry, the installation location and the enclosure, the usable energy and the rated power, the power conversion system and its IEEE 1547 grid-support functions, the point of interconnection and export control, the battery management system, the site controller and its communications, thermal management, the fire and gas detection, suppression, and explosion control integral to the installation, separation distances, the hazard mitigation analysis and the emergency response plan, factory and field testing including the capacity test, installation, decommissioning, warranty, and spares.
- Busway
Feeder and plug-in busway rated 600 V and below, listed to UL 857 and built to NEMA BU 1, used as a feeder, a riser, a transformer or switchboard connection, or an overhead distribution run that loads tap into at intervals. Covers the bus run as a listed system: the ratings, the bus bars and their joints, the housing and its enclosure type, the elbows, tees, offsets, flanged ends, tap boxes, end closures, expansion fittings, and fire-rated penetration fittings, the hangers and supports, identification, factory and field testing, installation, warranty, and spares, for three-phase and single-phase AC systems in indoor and outdoor locations.
- Busway Plug-In Units and Rack Power Distribution Units
Two product families that take power from a distribution run and hand it to a load at the point of use. The first is the plug-in unit that mounts on an opening of a plug-in busway run rated 600 V and below, listed to UL 857 with the busway series it mounts on: fusible-switch, circuit-breaker, non-fused disconnect, and receptacle tap-off units, with their overcurrent devices, fuse class or trip unit, stabs and ground connection, interlocks and padlock provisions, enclosure type, out-of-reach operating provisions, load-side terminations and cord drops, and ratings. The second is the rack-mount power distribution unit, the relocatable power tap, and the special-purpose relocatable power tap that distribute one branch circuit to the cord-connected equipment in an equipment rack or cabinet, in data centers, information technology equipment rooms, telecommunications rooms, equipment closets, laboratories, and patient care areas: basic, metered, monitored, and switched units, single and dual-input units, their input voltage, current, connection, plug, and cord, outlet types and retention, outlet bank protection, integral surge protection, metering granularity and accuracy, network interface, environmental sensors, and mounting. Covers identification, factory and field testing, installation, warranty, and spares for both families.
- Cable Tray Systems
Open-top cable tray systems used as the primary support and management method for electrical power, control, instrumentation, and communications cabling in commercial, institutional, and industrial buildings and process facilities. Covers ladder, ventilated trough, solid-bottom, wire-mesh (cable basket), and channel cable tray; steel, aluminum, and fiberglass (FRP) materials and their finishes; the selection of tray type, material, load/span class, width, and loading depth; fittings, covers, barriers, and dividers; the structural support and bracing of the tray; the grounding and bonding of the tray and its use as an equipment grounding conductor; the calculation of cable fill and the ampacity adjustment of cables in tray; and the testing, inspection, and acceptance of the installed system.
- Common Motor Requirements for Electrical Equipment
Common requirements for low-voltage three-phase squirrel-cage AC induction motors, 1/4 HP through 500 HP at 200-600 V, 60 Hz, furnished as part of mechanical, plumbing, HVAC, process, and electrical equipment and driven across the line, through combination or soft starters, or by a VFD. Written as a referenced-by standard that equipment specifications call rather than restating motor criteria.
- Common Work Results for Electrical
The umbrella standard for the electrical discipline, read together with every electrical power, lighting, communications, and electronic safety and security standard on a project. Declares the governing electrical code once; states the submittal content, installer qualification, listing and labeling, construction electrical safety, enclosure-type-by-location, trade coordination, equipment access and working space, division of responsibility for serving equipment furnished under other disciplines, sleeve and penetration, support and seismic restraint threshold, existing-building outage and cutting and patching, protection and cleaning, demonstration and training, and warranty provisions that the electrical standards inherit rather than restate. Carries no product requirements of its own.
- Conductors and Cables
Building wire and cable for power, lighting, branch circuit, and feeder applications rated 600V and below in commercial, institutional, and industrial buildings. Covers single conductors installed in raceways and cable tray, Type MC metal-clad cable, and Type AC armored cable; conductor materials (copper and aluminum); insulation types (THHN/THWN-2, XHHW-2, RHW-2, USE-2); ampacity selection and derating; voltage drop; color coding and conductor identification; splicing, connectors, and terminations; pulling and installation; insulation resistance testing; and field acceptance.
- Distributed Antenna Systems
In-building distributed antenna systems (DAS) that extend commercial cellular service into a building or a group of buildings: the signal source for each carrier, the head-end with its point of interface and combining, the coaxial and fiber distribution, the remote units, the indoor service antennas and radiating cable, the donor antenna where the source is off-air, power and standby power for the active equipment, remote monitoring, carrier coordination, acceptance testing, warranty, and spares. Covers passive, active, hybrid, and digital architectures, single-carrier and multi-carrier neutral-host service, and the licensed cellular bands from 600 MHz through the 3.7 GHz C-Band, on new construction and on existing buildings.
- Electric Heat Tracing
Electrical resistance trace heating applied to piping, vessels, and tanks for freeze protection, process temperature maintenance, and roof and gutter de-icing, in both ordinary and classified (hazardous) locations, using self-regulating, constant-wattage (zone), series-resistance, or mineral-insulated cable with associated controls, ground-fault equipment protection, and monitoring.
- Electric Vehicle Charging Equipment
Electric vehicle supply equipment (EVSE) as a listed product and the work that puts it into service, on commercial, institutional, industrial, multifamily, and residential projects with parking: AC Level 1 and Level 2 charging equipment and DC fast charging equipment, wall-mounted, pedestal-mounted, and ceiling-mounted, cord-and-plug-connected and hardwired, unidirectional and bidirectional. Covers the listing, the enclosure, the rated output, the connector and the cable, the cable management, the connection to the branch circuit, load management and the energy management system, network connectivity and the charging protocol, authorization and fee collection, energy measurement, the provisioning of EV-capable, EV-ready, and EVSE-installed parking spaces to the adopted codes, accessible charging spaces, identification, installation, commissioning, warranty, and spares.
- Electrical Equipment Labels
The labels, nameplates, directories and signs applied in the field to the enclosures of electrical equipment rated 1000 V and below, and of the medium-voltage equipment on the same project: switchgear, switchboards, panelboards, motor control centers, transformers, transfer switches, generators, drives, disconnects, starters, busway, meter enclosures and control enclosures. Covers the equipment identification nameplate with its designation and source, the nameplates on each device and compartment, the circuit directory, the warning and danger signs NFPA 70 requires on equipment for voltage, multiple sources, disconnect location, back-fed devices, series ratings and ungrounded systems, the arc-flash warning label as a product and its installation, the available fault current marking, service equipment signs, the marking of emergency and standby system equipment, nameplate material, colors, character heights and attachment, the ANSI Z535.4 format of safety signs, installation, warranty and spare stock.
- Electrical Installations in Hazardous (Classified) Locations
The electrical installation inside, and at the boundary of, every location classified under NFPA 70 Articles 500 through 516 on a water, wastewater, industrial, institutional, or commercial project: the area classification as a contract deliverable and the basis documents behind it (NFPA 497, NFPA 499, NFPA 820, NFPA 30, NFPA 30A, NFPA 58, API RP 500 and RP 505), the choice between the Division and Zone systems, the protection techniques of NFPA 70 500.7 as the menu per kind of equipment (explosionproof and dust-ignitionproof enclosures, purged and pressurized enclosures under NFPA 496, intrinsically safe systems under Article 504, nonincendive equipment and circuits, oil immersion, hermetic sealing, and combustible gas detection as a technique), the wiring methods permitted by class and division, conduit and cable seals and drainage, bonding within the classified location, the listing and marking every item of equipment must carry and its verification against the classification drawings, the specific-occupancy articles, and the classified-location inspection before energization and the record of classified areas delivered at closeout. Written for the wet wells, headworks, digester and gas handling areas, sludge galleries, chemical rooms, and fuel areas of treatment plants and pump stations, and equally for a fuel dispensing island, a paint booth, or a dust-handling process.
- Electrical Power Monitoring and Metering
Permanently installed electric power metering and monitoring for new and retrofit commercial, institutional, and multi-tenant buildings, including service-entrance revenue metering, tenant sub-metering, panelboard and feeder load-category metering, branch-circuit power monitoring, and the current and voltage sensors that serve them. Covers accuracy classes, current-sensing methods, measured parameters, data logging, communication protocols, and integration scope.
- Electrical Rooms
The dedicated indoor electrical room and the electrical closet as a space: the room that houses service equipment, switchgear, switchboards, panelboards, motor control centers, dry-type transformers, transfer switches, drives, UPS modules, control-power batteries and the open or paralleling generator sets installed indoors. Covers the working space and the dedicated electrical space the adopted electrical code requires about the equipment, headroom, the number of entrances, door swing, clear opening and panic hardware, locking and free egress, the fire-resistance rating of the enclosing construction where a code sets one, the exclusion of piping and ductwork foreign to the electrical installation, water protection at the door and on the floor, the heat-release basis and the ventilation or cooling performance the room has to deliver, the temperature and humidity limits taken from the equipment ratings, illumination and emergency illumination of the working space, the convenience receptacle, housekeeping pad provision, floor finish, the room ground bar, the signs on the room door, the coordination drawing that proves every clearance before the room is framed, and the field verification before the room is closed in and before equipment is set.
- Electrical Safety Program
Establishing a facility-level written electrical safety program governing all work on or near energized equipment (50 V and above, from 120 V branch circuits through 15 kV distribution) on commercial, institutional, industrial, and infrastructure projects. Covers arc flash risk assessment methodology, arc flash and approach boundary labeling, energized electrical work permits, lockout/tagout, PPE selection, qualified-person work boundaries, training, and the program review cycle. Addresses both owner-furnished programs under NFPA 70E and contractor-submitted safety program submittals.
- Floor Boxes and Poke-Through Devices
Specifying in-floor power and low-voltage service assemblies for commercial and institutional spaces where overhead distribution cannot reach mid-floor workstations - preset and adjustable concrete floor boxes in slab-on-grade and elevated cast-in-place decks, fire-rated and non-fire-rated poke-through devices penetrating rated concrete floor-ceiling assemblies, and the covers, service fittings, and modular inserts that serve power, data, voice, and audiovisual outlets in offices, conference rooms, ballrooms, classrooms, retail concourses, and transportation terminals (new construction and interior fit-out).
- Grounding and Bonding for Electrical Systems
The grounding and bonding of electrical systems rated 1000 V and below in commercial, institutional, industrial, and water and wastewater facilities: the grounding electrode system and each of its electrodes (concrete-encased, ground ring, rod, pipe and plate, structural metal, metal water pipe, electrolytic), the soil basis the electrode design rests on, the grounding electrode conductor and its routing, the service grounding including the main bonding jumper, the bonding of service raceways and the intersystem bonding termination, the grounding and bonding of every separately derived system, the equipment grounding conductors of feeders and branch circuits and the rules that size them, isolated-ground circuits, the bonding of metallic piping, structural metal and other metal systems, the common bond to the lightning protection, telecommunications and cathodically protected systems, the grounding of direct-current control systems, ground bars, exothermic, compression and mechanical connections, and the field tests that prove the installed system. Every equipment standard in the corpus hands the equipment grounding and bonding of its equipment to this standard.
- Intrusion Detection Systems
Electronic intrusion detection (burglar alarm) systems for commercial, institutional, and industrial facilities. Covers control panels and communicators, detection devices (PIR, dual-technology, glass-break, door/window contacts, vibration/seismic, beam detectors), perimeter and interior protection zones, local annunciation, keypad and credential arming stations, central-station signal transmission, and UL-listed monitoring service. Applies to new construction and major renovations across office, retail, warehouse, healthcare, education, government, and critical-infrastructure project types.
- Lightning Protection Systems
Structural lightning protection systems for buildings and ordinary structures, covering air terminals and strike termination, main and down conductors, conductor materials and dissimilar-metal limitations, grounding electrodes and the ground ring, bonding and potential equalization of metal bodies, and coordination of surge protection at the electrical service. Applies to new construction and retrofit of commercial, institutional, and industrial structures seeking a UL Master Label or LPI-certified system.
- Low Voltage Panelboards (Superseded)
never for new adoptions — this standard has been merged into Panelboards, which carries its full content under the simple name.
- Low-Voltage Variable Frequency Drives
Individually mounted, enclosed pulse-width-modulated (PWM) variable frequency drives rated 600 V and below, specified under the electrical division for speed control of three-phase AC induction and permanent-magnet motors in non-HVAC applications — process pumps and fans, compressors, conveyors, mixers, water and wastewater treatment, and general industrial, institutional, and municipal motor loads. Covers fractional through 500 HP, wall- and floor-mount construction, NEMA 1 through 4X enclosures, indoor and outdoor service, variable- and constant-torque duty, input protection, harmonic mitigation, bypass, network communication, output filtering, and acceptance testing.
- Medium-Voltage Cables
Shielded extruded-dielectric power cable rated 2.4 kV through 35 kV, in the 5 kV, 8 kV, 15 kV, 25 kV, 28 kV, and 35 kV classes, purchased and installed by the Owner's contractor for primary distribution on a campus, a plant, or a building site, from the service point or the substation to the switchgear, the transformer, the unit substation, or the motor it feeds. Covers the conductor, the insulation compound and temperature rating, the voltage class and insulation level, the shield construction, the jacket and armor, single-conductor and multi-conductor assemblies, listing, the ampacity basis, pulling limits, splices, terminations and separable connectors, shield grounding, arc-proofing in manholes, identification, factory tests, the field withstand test method, voltage, and duration and the diagnostic tests, installation in duct, conduit, tray, and direct burial, delivery, warranty, and spares.
- Nurse Call Systems
Patient-to-staff audible and visual communication systems for healthcare facilities (hospitals, skilled nursing, assisted living, hospice, outpatient care), covering wired/BUS, IP/PoE, and wireless (Wi-Fi, DECT 6.0) architectures and all components — patient call stations, bathroom emergency stations, corridor dome lights, staff and master nurse stations, central controllers/servers, and EMR/ADT (HL7), RTLS, and bed-status integration interfaces. New construction and major renovation in NFPA 99 Category 1 and 2 occupancies requiring ANSI/UL 1069-listed equipment.
- Panelboards
Dead-front panelboards rated 1000 V and below, listed to UL 67 and built to NEMA PB 1, that subdivide a feeder or a service into branch circuits and feeders and hold the overcurrent device for each, whether installed as service equipment or downstream of switchgear, switchboards, transformers, or other panelboards. Covers the ratings, the interrupting rating basis, the main device, the bus, the cabinet and front, the branch circuit devices and their accessories, the surge protection and metering provisions built into the cabinet, identification, factory and field testing, installation, warranty, and spares, for single-phase and three-phase AC systems in indoor and outdoor locations.
- Photovoltaic Systems
Grid-interactive photovoltaic power systems on and around commercial, institutional, industrial, and multifamily buildings and campuses, from a few kilowatts to several megawatts, on a roof, on the ground, or on a carport or canopy, interconnected with the premises wiring under NFPA 70 Articles 690 and 705, including a multimode system whose storage is specified separately. Covers the modules and the cell technology, the inverters and the power conversion architecture, the maximum DC voltage, rapid shutdown and arc-fault protection, the DC source and output circuits, their combiners, connectors, overcurrent protection, and PV-specific disconnects, DC surge protection, the method and the application for interconnection with the utility, the mounting system as a delegated design on a roof, on the ground, or on a canopy, the bonding of modules and racking, production metering and monitoring, commissioning to IEC 62446-1, performance acceptance, the production guarantee, the warranties, and the spares.
- Power-Factor Correction Capacitors
Fixed and automatic (switched) shunt capacitor banks for power-factor correction on low-voltage (600 V and below) and medium-voltage (above 600 V through 35 kV) distribution systems in industrial plants, water and wastewater treatment facilities, data centers, hospitals, institutional campuses, and utility-customer service entrances. Covers individual capacitor units, detuned banks with series reactors, thyristor-switched banks, controllers, and integral protection/switching devices, indoor or outdoor, including the harmonic assessment and detuning needed where VFDs, rectifiers, or UPS share the bus.
- Public Address and Paging Systems
centralized amplifier-based or IP-networked audio distribution for routine announcements, background music, general intercom, and zone-based paging across buildings and campuses (schools, universities, offices, industrial facilities, warehouses, healthcare campuses, correctional facilities, and transportation terminals). Covers system architecture (70-volt constant-voltage analog vs. IP-networked audio), master and remote paging stations, amplifiers and digital signal processors, loudspeakers, supervision, intelligibility, and the interface to fire alarm voice evacuation.
- Raceways and Conduit
Conduit, tubing, and raceway systems that enclose and protect electrical power, lighting, and signaling conductors in commercial, institutional, and industrial buildings — including rigid metal conduit, intermediate metal conduit, electrical metallic tubing, flexible conduits, rigid PVC conduit, surface raceways, metal and nonmetallic wireways, and conduit fittings, boxes, and supports. Covers indoor and outdoor, exposed and concealed, wet and dry, and direct-burial raceway routing for branch circuits and feeders rated 1000V and below.
- Selective Electrical Demolition
Planned, sequenced removal, abandonment-in-place, capping, temporary support, and relocation of existing 0-600/1000 V electrical systems within a defined limit-of-work boundary on renovation, tenant improvement, adaptive reuse, occupied-building phased, and systems-replacement projects. Covers pre-demolition hazard assessment (arc flash, energized work permit, lockout/tagout sequence), deenergization verification, coordination with the live system remaining in service, salvage decisions, abandoned cable identification and removal, penetration patching, and as-built documentation of modified or abandoned circuits.
- Structured Cabling Systems
The passive telecommunications cabling plant of a commercial, institutional, industrial, healthcare, or multifamily building: the horizontal cabling from each telecommunications room to the work-area outlets, the backbone cabling between telecommunications spaces, the cabling of the entrance facility up to the service provider demarcation, and the connecting hardware that joins them, including patch panels, modular jacks and faceplates, consolidation points, cross-connects, fiber enclosures, patch cords, and equipment cords. Covers balanced twisted-pair cabling of Category 5e through Category 8, multimode and singlemode optical fiber, cable listing by the space it occupies, Power over Ethernet thermal provisions, field certification testing and the test report, administration and labeling under ANSI/TIA-606, installer and fiber termination qualifications, the manufacturer system warranty, and spares, on new construction, tenant improvement, and renovation.
- Surge Protective Devices
Permanently connected, low-voltage (1000V and below) surge protective devices (SPDs) installed at the service entrance, at distribution and branch panelboards, and at the point of use to limit transient overvoltages on the AC power system. Covers Type 1 (line side of the service disconnect), Type 2 (load side of the first overcurrent device), and Type 3 (point-of-utilization) SPDs for commercial, institutional, industrial, and multifamily buildings on 208Y/120, 240/120, 480Y/277, 240 delta, and 600Y/347 systems. Addresses SPD type and coordinated multi-stage application, the electrical ratings that govern protection (voltage protection rating, maximum continuous operating voltage, nominal discharge current, surge current capacity, and short-circuit current rating), protection modes including the neutral-to-ground mode on separately derived systems, construction and end-of-life safety (thermal disconnect, status indication, monitoring contacts, replaceable modules), and the installation rules that decide whether an SPD actually protects the load, above all conductor lead length.
- Telecommunications Bonding and Grounding
Customer-premises telecommunications bonding and grounding for commercial, institutional, and industrial buildings per ANSI/TIA-607-E. Covers the Primary Bonding Busbar (PBB), Secondary Bonding Busbar (SBB), Telecommunications Bonding Backbone (TBB), Telecommunications Equipment Bonding Conductor (TEBC), rack and cabinet bonding busbars and jumpers (RBB/RBJ), bonding grids in equipment rooms, shielded cable plant grounding, surge protection for telecommunications circuits, and grounding of metallic cable shields and outside-plant entrance cables. Coordinates with the building electrical grounding electrode system at the point of connection only.
- Telecommunications Rooms and Pathways
The telecommunications spaces of a building and the pathways inside it under ANSI/TIA-569: the entrance facility and entrance room, the equipment room, the telecommunications rooms and telecommunications enclosures that serve each floor, and the rooms that house the main and intermediate cross-connects, with their location, size, floor loading, ceiling height, construction and finishes, backboards, door, lighting, dedicated power provisions, environmental criteria, and fire protection coordination; the riser sleeves and slots between floors and through walls, the cable runway and cable tray inside telecommunications spaces, the J-hooks and other non-continuous supports, the conduit dedicated to telecommunications cable with its bend and pull point rules, the surface raceway that carries telecommunications cable, and the equipment racks and cabinets, with their identification under ANSI/TIA-606, installation, room-ready acceptance, warranty, and spares, on new construction, tenant improvement, and renovation of commercial, institutional, healthcare, industrial, and multifamily buildings.
- Underground Electrical Duct Banks
Concrete-encased and direct-buried conduit duct banks for site electrical and communications distribution between buildings, transformers, substations, switchgear, generators, and exterior equipment, including the raceway configuration, concrete encasement and reinforcement, cover and separation, manhole and handhole interfaces, building entries, and the proving of the installed system.
- Utility Manholes and Handholes
The below-grade access structures of an underground electrical or communications duct system on a campus, a plant, or a building site: precast concrete manholes and vaults that a person enters to pull, splice, and rack cable, and the handholes of precast concrete, polymer concrete, fiberglass, or composite that are worked from grade. Covers the choice between a manhole and a handhole, the load rating of each structure, the precast concrete sections and their joints, the handhole enclosure and its cover, the duct windows and terminators at the wall, frames, covers, legends, locking and grade adjustment, the access opening, steps and ladders, cable racks and arms, pulling irons, sumps and drainage, the ground rod sleeve and bonding provisions, the structure's own excavation, base, and backfill, field checks, warranty, and spares.
- Video Surveillance Systems
IP-based video surveillance systems (VSS / CCTV) for commercial, institutional, industrial, and multi-family construction. Covers network cameras (fixed, PTZ, fisheye/multi-sensor, LPR), video management software (VMS), network video recorders (NVR), video storage, dedicated PoE surveillance switches, video analytics, monitors and workstations, and all cabling and pathways dedicated to the VSS, on new construction, tenant improvement, and major renovation.
- Wireways and Auxiliary Gutters
Metal wireways under NFPA 70 Article 376, nonmetallic wireways under Article 378, and auxiliary gutters under Article 366, listed to UL 870, used to carry, group, and give access to insulated conductors rated 1000 V and below between and alongside switchgear, switchboards, panelboards, meter centers, motor control centers, control panels, and the raceways that serve them. Covers the trough as a listed product: the trough type and the classification of each run as a wireway or an auxiliary gutter, the voltage rating, the material, enclosure type, and finish, the covers and knockouts, the cross-section and conductor fill, the 30-conductor ampacity adjustment threshold, the splice and tap space, the fittings, end plates, equipment connectors, and expansion fittings, the bonding continuity of the assembly, the supports and their spacing, the 30 ft auxiliary gutter length limit, the connection to the equipment the trough adjoins, field testing, installation, warranty, and spares, for indoor and outdoor locations.
- Wiring Devices
The receptacles, snap switches, wall-box dimmers, wall-box occupancy and vacancy sensors, and wall plates installed in outlet boxes on branch circuits rated 250 V and below and 60 A and below, in commercial, institutional, industrial, multifamily, and residential buildings. Covers device grade, the ampere rating and NEMA WD 6 configuration of receptacles, hospital-grade, isolated-ground, controlled, USB, surge-protective, locking, and special-purpose receptacles, the ground-fault and arc-fault devices installed at the outlet, tamper-resistant and weather-resistant devices and their covers, switch types and ratings, stand-alone dimmers and sensors with no connection to a control system, device color and plate material and finish, mounting height and orientation, terminations, device identification, field testing, warranty, and spares.
- Wiring System Identification
The identification of the wiring system itself on installations rated 1000 V and below, in commercial, institutional, industrial, healthcare and multifamily work: the color coding of ungrounded, grounded and equipment grounding conductors by phase and by voltage system, the orange high leg, the polarity identification of direct-current circuits, the identification legend NFPA 70 210.5(C) and 215.12(C) require, the wire markers on conductors at terminations, the tags on feeders and cables at pull points, handholes and terminations, the markers and color bands on raceways, the circuit marking of junction and pull box covers, the circuit label on a wiring device plate, the warning tape and route markers over buried runs, the marking of the boxes and raceways of emergency and standby systems, and the project's system color convention that all of these share with the equipment labels.
Structural
Concrete
(22)
- Architectural Precast Concrete
Plant-cast precast concrete units whose exposed face is a specified architectural finish, installed as cladding on the exterior walls of commercial, institutional, healthcare, educational, civic, and multifamily buildings: spandrel panels, full-story wall panels, column covers, cornices, copings, sills, window surrounds, reveal panels, soffit panels, and custom profiled trim, in solid, face-mix-over-backup, and insulated sandwich configurations, with as-cast, form-liner, sandblasted, acid-etched, retarder-exposed-aggregate, bushhammered, honed, polished, thin-brick-faced, and stone-faced finishes. Covers the delegated design of the units and their connections, the face mix and its color, the finish and its acceptance by sample and mockup, reinforcement and connection hardware corrosion protection, the insulation of sandwich panels, joint width, PCI MNL-117 and MNL-135 tolerances, plant certification and quality control, erection, field repair, and cleaning.
- Cast-in-Place Concrete
Structural cast-in-place concrete for buildings and structures — constituent materials, mixture proportioning and qualification, exposure-class durability requirements, ready-mixed production and delivery, placement and consolidation, hot- and cold-weather concreting, field testing, and evaluation and acceptance of the hardened concrete. Applies to footings, foundations, grade beams, mat foundations, below-grade walls, slabs on grade, elevated slabs and decks, columns, beams, and structural walls on commercial, institutional, and industrial projects.
- Concrete Accessories and Embeds
ancillary materials and pre-installed hardware set in place before or during cast-in-place concrete placement to serve structural, waterproofing, moisture-control, or attachment functions - PVC, rubber, and hydrophilic waterstops; under-slab vapor retarder placement; wire, plastic, and precast bar supports (chairs); dovetail anchor slots for masonry veneer; embedded plates, angles, and weld plates; cast-in anchor rods and headed studs; and expansion-joint filler. Applies to all cast-in-place structures including buildings, industrial facilities, water and wastewater plants, below-grade walls, slabs-on-grade, and elevated decks.
- Concrete Construction Joints and Waterstops
Design and construction of joints in cast-in-place concrete that must control water infiltration, accommodate movement, or both - construction (cold) joints, contraction/control joints, expansion/isolation joints, and seismic joints. Covers the whole joint system: layout and spacing logic, waterstop type selection and performance criteria (PVC, rubber/EPDM, hydrophilic, external), preformed filler, splice and transition detailing, and inspection. Primary applications are water-retaining and water-excluding below-grade structures (tanks, reservoirs, wet wells, vaults, tunnels), water- and wastewater-treatment basins and channels, and below-grade building walls and slabs where groundwater exclusion is required; also structural construction joints in above-grade walls and elevated slabs.
- Concrete Curing and Finishing
curing methods, materials, and duration plus surface finishing for cast-in-place concrete placements - structural slabs, elevated decks, walls, columns, footings, grade beams, and site flatwork. Covers wet cure, sheet cure, membrane-forming curing compounds (ASTM C309, C1315), temperature-protection blankets, formed-surface curing, the finishing-to-curing transition, the full range of surface finishes (screed, broom, float, steel-trowel, exposed aggregate, rock salt, swirl, formed), FF/FL flatness and levelness tolerances per ACI 117, and surface-defect acceptance and remediation.
- Concrete Equipment Pads
Cast-in-place concrete equipment pads and housekeeping pads that receive mechanical, electrical, and plumbing equipment - generators, pad-mounted and dry-type transformers, switchgear and switchboard lineups, chillers, air handlers, condensing units, pumps, compressors, boilers, and similar equipment - whether the pad bears on grade, on an interior finished floor, on a structural slab, or on an exterior platform. Covers the decisions a pad standard actually owns: pad geometry and height, attachment to the supporting concrete, reinforcement method, cast-in and post-installed equipment anchorage, cast-in raceway and grounding provisions, liquid containment, surface finish and grout bed, isolation from adjacent construction, dimensional and anchorage tolerances, and the verification performed before concrete is placed and before equipment is set.
- Concrete Formwork and Accessories
Temporary cast-in-place concrete formwork systems and accessories on commercial, institutional, industrial, and infrastructure projects — wall, column, beam, slab-soffit, foundation, and architectural concrete forms; form ties and hardware; chamfer, rustication, and form liners; release agents; void forms; and shoring/reshoring for multistory construction, including formwork loads, lateral pressure, deflection control, tolerances, and stripping sequence.
- Concrete Reinforcement
Steel reinforcement for cast-in-place structural concrete: deformed and plain reinforcing bars, welded wire reinforcement, headed deformed bars, and the lap, mechanical, end-bearing, and welded splices that join them. Covers the bar standard and grade for each reinforcement class, the bars the seismic-force-resisting system requires, corrosion-protected reinforcement and the system that provides it, fabrication and bending, placement, spacing, and concrete cover, the splice policy for each splice type, welding of reinforcement under AWS D1.4, placement tolerances, the pre-placement inspection, special inspection of reinforcement, and the delivery, storage, and handling of coated and uncoated steel.
- Concrete Repair and Restoration
assessment, surface preparation, material selection, and application of repair systems for existing hardened concrete — crack repair (epoxy and polyurethane injection, routing and sealing), partial- and full-depth patching, bonded overlays, corrosion mitigation of embedded reinforcement, protective surface treatments, and FRP strengthening as part of a repair scope. Applies to buildings, parking and water/wastewater structures, and industrial floors across interior, exterior, submerged, freeze-thaw, chemical, and chloride/carbonation exposures, on renovation, historic rehabilitation, and repair-of-new work.
- Deep Foundations (Piles and Drilled Piers)
Deep foundations for buildings, structures, and infrastructure where shallow foundations are inadequate — poor bearing soils, high concentrated loads, expansive or collapsible soils, scour-susceptible sites, or where differential settlement must be controlled. Covers driven piles (steel H-piles, steel pipe piles, precast prestressed concrete piles, timber piles), cast-in-place drilled shafts and piers (straight-shaft and belled/underreamed), continuous flight auger (CFA/auger-cast) piles, micropiles, and helical piles, including materials, installation equipment and methods, field monitoring, load and integrity testing, and acceptance criteria.
- Epoxy and Cementitious Anchoring Grouts
adhesive and cementitious grouts that develop structural bond for post-installed rebar dowels, anchor bolts, threaded rod, and headed studs drilled into hardened concrete, masonry, or rock; and precision epoxy or non-shrink grout placed under equipment baseplates, machinery sole plates, and column base plates where full contact and load transfer are required. Covers interior, exterior, submerged, chemical-exposure, and high-temperature service when the correct product is selected.
- Grouted Column Base Plates and Bearing Plates
Installation, material selection, and acceptance of grouted column base plates and bearing plates on concrete foundations, piers, and pedestals, where a cementitious or epoxy non-shrink grout layer fills the void between a leveled steel plate and the concrete substrate. Covers structural steel column bases, equipment bearing plates, and beam bearing plates on commercial, industrial, and institutional buildings, including leveling, formwork, grout selection and placement, curing, anchor rod torquing, and field verification.
- Non-Shrink Grout
Load-bearing non-shrink grout (hydraulic cement-based or epoxy) placed under structural steel base plates, column and bearing plates, machinery and equipment foundations, precast concrete bearing pads, crane rail sole plates, bridge bearing assemblies, and anchor bolt leveling pockets, wherever dimensional stability under sustained compressive load is required across commercial, industrial, institutional, and infrastructure work.
- Post-Installed Concrete and Masonry Anchors
attaching structural and non-structural elements to existing hardened concrete or masonry (CMU, brick) substrates with anchors set in a drilled hole - torque-controlled and displacement-controlled expansion anchors, undercut anchors, concrete screw anchors, and adhesive (chemical) anchors using threaded rod or reinforcing-bar inserts. Covers cracked-concrete-qualified and seismic-qualified systems, sustained-tension and overhead adhesive installations, anchorage in dry or saturated substrates, hole preparation, torque verification, and mandatory special inspection.
- Post-Tensioned Concrete
Cast-in-place post-tensioned (PT) concrete for buildings and parking structures, where prestressing steel is tensioned after the concrete has cured and the force is anchored against the hardened member. Covers both dominant systems: unbonded single-strand tendons (greased-and-sheathed seven-wire strand, the standard system for elevated building floors and parking decks) and bonded multistrand tendons (strand bundled in ducts that are grouted after stressing, used for transfer girders, longer spans, and heavier post-tensioned beams). Addresses prestressing strand, anchorages and couplers and their qualification, sheathing and corrosion protection including encapsulated and electrically-isolated tendons for parking and aggressive exposure, tendon profile and placing tolerances, concrete strength at stressing, stressing operations and sequence, elongation measurement and acceptance, wedge seating, tendon cutting and pocket treatment, grouting of bonded tendons, and field quality control and records. Applicable to commercial, institutional, residential, and parking buildings.
- Precast Concrete
Plant-fabricated precast and prestressed (pretensioned) concrete for buildings, including structural precast — columns, beams, spandrels, double-tees, hollow-core plank, solid and insulated wall panels, stair and landing units — and architectural precast cladding panels with specified exposed finishes. Covers concrete and release-strength requirements, pretensioned and conventionally reinforced production, connection hardware and embedded plates, architectural finishes (form liner, exposed aggregate, acid-etch, sandblast), PCI plant certification and quality control, product and erection tolerances, bearing pads, grouting, joint sealant coordination, erection, and patching. Applicable to commercial, institutional, industrial, parking, and multi-family buildings.
- Shallow Foundations (Spread and Strip Footings)
Buildings, structures, and site improvements that bear directly on competent soil or rock within a few feet of finish grade. Covers the execution and quality assurance of spread (isolated column) footings, continuous wall (strip) footings, combined footings, and strap (cantilever) footings — forming, bearing-surface preparation, reinforcement and dowel layout, anchor-bolt and embedded-plate setting, keyways and construction joints, lean-concrete sub-bases, and bearing-inspection hold points. Applies to commercial, institutional, industrial, and multi-family residential work.
- Shotcrete
pneumatic placement of hydraulic-cement concrete by wet-mix or dry-mix process for structural and non-structural work — shoring and soil-nail/tieback walls, slope and rock stabilization, tunnel and underground linings, void fill and member encasement, pools and water features, and form-free placement of complex geometries. Covers mix design, materials, equipment, nozzleman qualification, preconstruction test panels, placement, curing, and acceptance testing for original construction.
- Slab-on-Grade
Concrete slabs on ground that serve as building floors on commercial, institutional, industrial, warehouse, and pre-engineered metal building projects, bearing directly on a prepared subgrade or on a granular subbase rather than on a structural frame. Covers the decisions that make a floor slab a designed element rather than a poured surface: the design basis the Engineer of Record records (subgrade modulus, design loads, thickness), the granular subbase and its surface, the condition of the supporting surface when concrete is placed, whether a vapor retarder is provided beneath the slab and the sequence it fixes, the crack-control strategy (plain, welded wire reinforcement, deformed bars, steel or synthetic macrofibers, shrinkage-compensating concrete, or post-tensioning) and the form, position, and support of reinforcement within the slab, thickened edges that act as integral grade beams, contraction, isolation, and construction joint layout, load transfer across joints, joint filling, floor flatness and levelness by F-numbers, the pre-placement verification, and acceptance of the finished floor.
- Tilt-Up Concrete
site-cast tilt-up wall panels for low-rise and mid-rise buildings, where concrete panels are cast horizontally on the slab or a casting bed, tilted into position, and braced until the structural frame is complete. Covers warehouse, distribution, manufacturing, big-box retail, and self-storage buildings, including solid, ribbed, and insulated sandwich panels, bond breaker, lifting and bracing hardware, connections, finishes, and tie-in to the structural diaphragm.
- Under-Slab Vapor Barriers
Vapor barriers and vapor retarders installed in direct contact with soil or granular fill beneath concrete slabs-on-grade in commercial, institutional, and residential construction. Covers material selection, ASTM E1745 performance-class determination, true vapor barriers (less than or equal to 0.01 perms) for high-sensitivity occupancies, placement sequence, lap and seam requirements, penetration sealing, repair, and coordination with concrete placement.
- Water-Retaining Concrete Structures
The cast-in-place concrete of structures that hold or exclude water, wastewater, sludge, or process liquid by the concrete itself and its joints, designed under ACI 350: treatment basins, clarifier and aeration tanks, filters, clearwells, contact tanks, wet wells, channels, digesters, equalization and holding tanks, chemical containment, and the below-grade galleries and vaults a plant designs to stay dry under groundwater. A layer read with Cast In Place Concrete, Concrete Reinforcement, Concrete Formwork, Concrete Curing And Finishing, and Concrete Joints And Waterstops, and with Common Work Results Process on a process project: it adds only what ACI 350 adds, the exposure and durability limits for liquid-retaining concrete, the reinforcement and cover that control cracking at liquid faces, the placement sequence of base slabs and walls, the casting and grouting of embedded wall pipes and gate thimbles, form ties in liquid-retaining walls, the hydrostatic tightness test of the completed structure under ACI 350.1, leak repair and retest, and backfill after the test.
Steel & Metal Fabrications
(16)
- Anchor Rods and Embedded Steel
cast-in-place anchor rods, headed anchor bolts, and embedded steel items (bearing plates, embed plates, pipe sleeves, weld studs, and miscellaneous cast-in anchors) set into concrete foundations, grade beams, piers, or walls before or during concrete placement to positively anchor structural steel columns, equipment bases, canopy and sign posts, utility poles, and similar elements on commercial, industrial, institutional, and heavy civil projects. Covers ASTM grade selection, fabrication, protective coatings, setting templates, pipe sleeves, leveling-nut assemblies, and field inspection of cast-in items.
- Cold-Formed Metal Framing
Structural cold-formed steel framing designed under AISI S100 and AISI S240 and, where the framing participates in a seismic force-resisting system, AISI S400. Covers load-bearing stud walls, exterior non-load-bearing wind-bearing wall framing in both infill and bypass arrangements, cold-formed steel floor joists, roof rafters, and trusses, cold-formed steel shear walls and braced walls, and the parapet, canopy, and soffit framing that carries calculated load. Addresses the division of design responsibility between the Engineer of Record and the specialty engineer, sheet steel and metallic coating selection, member designation and identification, out-of-plane deflection criteria, movement accommodation at the head of wall, bridging and bracing, screwed, welded, powder-actuated, clinched, and bolted connections, opening and built-up member framing, web penetrations and field modification, erection tolerances, listed fire-resistance-rated assemblies, and field inspection.
- Common Work Results for Structural Steel
On every project that includes hot-rolled structural steel work — commercial, institutional, industrial, mixed-use high-rise, and infrastructure — to establish the unified administrative and quality-assurance envelope for hot-rolled structural steel sections: fabricator and erector qualification (AISC certification, IAS AC172 accreditation), the common submittal hierarchy (shop and erection drawings, MTRs and CMTRs, WPS/PQR, welder qualifications, delegated-design connection calculations, product data), delivery and storage of steel, fabricator/erector/contractor coordination, pre-erection survey and base-plate grouting responsibility, special-inspection administration under IBC Chapter 17, and the non-conforming work and corrective-action process spanning all structural steel sections.
- Metal Building Systems
Pre-engineered (factory-fabricated) metal building systems (PEMBs/MBS) for single-story and low-rise non-residential construction procured as an integrated, delegated-design package from one manufacturer - primary rigid frames (clear-span, multi-span, lean-to, modular), secondary framing (purlins, girts, eave struts), manufacturer-supplied wall and roof panels, skylights, ventilators, insulation, integrated crane runway and mezzanine framing, and all connection hardware. Typical applications include warehouses, distribution centers, light manufacturing, aviation hangars, self-storage, and agricultural facilities.
- Metal Fabrications
architecturally exposed, custom shop-fabricated steel, stainless, and aluminum elements that complete the building envelope and interior fit-out but are not primary framing or standard stair/railing assemblies. Covers custom canopy and sunshade (brise-soleil) frames and blades, architectural screens and grille panels, custom access hatches and pit/trench covers with architectural frames, pipe sleeves and escutcheons, equipment enclosures and housings with specified finishes, corner guards with architectural finishes, coping and cap-angle assemblies, planter and site-furniture frames, and custom steel trim. Use where the metal is exposed to view and the architect specifies finish, profile, tolerance, and assembly.
- Metal Gratings and Floor Plates
Open-grid bar grating of carbon steel, stainless steel, and aluminum in welded, pressure-locked, swaged, and riveted construction, molded and pultruded fiberglass-reinforced plastic grating, and solid raised-pattern floor plate of steel, stainless steel, and aluminum, furnished as the walking surface of equipment platforms, mezzanines, catwalks, pipe-rack and tank-top access ways, and as removable covers over trenches, pits, sumps, and equipment wells in commercial, institutional, industrial, water and wastewater, power, and process facilities. Covers the design loads and the deflection limit the panels are sized to, the derivation of bearing bar depth, thickness, and spacing from the NAAMM load tables, the opening-size limit on accessible routes and in the means of egress, bar surface, banding, FRP construction, resin, surface, and fire performance, floor plate pattern, thickness, and slip-resistant treatment, finishes, fastening, removable panels and their handling weight, trench and pit covers, installation, field verification, delivery, warranty, and spare clips.
- Metal Stairs and Railings
Shop-fabricated metal stairs and railing systems for commercial, institutional, and industrial buildings — egress and convenience stairs built as steel pan stairs with concrete fill, steel plate (formed plate) stairs, and bar-grating-tread stairs, including their stringers, treads, risers, landings, and supporting framing, together with the handrails and guards (guardrails) of steel, aluminum, or stainless pipe, tube, and picket. Covers structural design for the IBC stair uniform live load and concentrated load, deflection and vibration serviceability, tread and riser dimensions and slip-resistant nosings to the IBC means-of-egress provisions, the IBC structural loads on handrails and guards (concentrated, uniform, and infill), shop and field welding to AWS D1.1, bolted and anchored connections, hot-dip galvanizing and shop priming, and field finishing.
- Miscellaneous Metals
Utility steel items shop-fabricated for a building or plant that are not part of the primary frame on the structural drawings and carry no architectural finish requirement: fixed vertical ladders with their ladder safety systems or personal fall arrest anchorage, ship's ladders and alternating tread devices, loose steel lintels and masonry shelf angles shown outside the structural drawings, slab and curb edge angles and nosings, loose embedded steel furnished for casting into concrete by others (embed plates, weld plates, seat angles, and anchor channels serving the items of this standard and architectural metal fabrications), the angle frames of utility trench and pit covers, loose equipment supports, stands, and rooftop dunnage not furnished with the equipment, and unrated steel pipe guard posts and column and door-jamb guards that protect building elements and equipment from impact. Covers the material grade for each product form, fasteners and anchors, the shop corrosion protection policy for interior and for exterior and masonry-embedded items, the OSHA and ANSI/ASSP A14.3 fall protection decision for fixed ladders, ship's ladder geometry, lintel bearing and shelf angle segmentation, embed anchorage, trench frame material and section, dunnage clearance and design responsibility, guard post size, fill, cap, and anchorage, exposed weld treatment, installation, delivery, and warranty, in commercial, institutional, industrial, water and wastewater, and multi-family buildings.
- Overhead Cranes and Hoists
Specifying, procuring, and installing electrically operated overhead material handling equipment in industrial, process, and manufacturing facilities — top-running single- and double-girder bridge cranes, underhung/under-running bridge cranes, monorail systems, and electric chain and wire-rope hoists. Covers duty classification, hoist type and lift height, runway electrification, bridge/trolley drives, pendant and radio controls, seismic and wind restraint inputs, and both new installations and upgrades to existing runway systems for water/wastewater plants, manufacturing facilities, power plants, pump stations, and maintenance bays.
- Roof and Facade Fall Protection Anchorage
Permanent and semi-permanent fall protection anchorage installed on low-slope and sloped roofs, parapets, and building facades to protect workers during maintenance, window washing, roofing, and facade access. Covers welded or bolted structural anchor plates, parapet clamps, non-penetrating standing-seam clamps and counterweight systems, concrete and masonry embedded anchors, davit base sockets, horizontal lifeline (HLL) cable and rail anchorage, and engineered certification of anchors for personal fall arrest and travel restraint systems on new construction and retrofit.
- Shop Painting and Galvanizing of Steel
Shop-applied corrosion protection for structural steel and miscellaneous metals fabricated off-site, including shop prime painting (zinc-rich, alkyd, epoxy, or urethane primers), hot-dip galvanizing of fabricated assemblies (ASTM A123) and hardware (ASTM A153), duplex galvanize-plus-paint systems, and repair of damaged galvanized coatings (ASTM A780), for building frames, joists, stairs, railings, lintels, embeds, and ornamental ironwork across commercial, institutional, industrial, and infrastructure projects.
- Steel Deck
Cold-formed steel floor and roof deck furnished and installed under the Steel Deck Institute standards: composite floor deck acting with the concrete slab above it, non-composite form deck serving as a permanent form, roof deck carrying the roofing assembly, and acoustical roof deck. Covers the division of design responsibility for the deck and its diaphragm, manufacturer and installer qualification, sheet steel and metallic coating selection, the basis for profile, depth, gauge, and section properties, diaphragm design basis, attachment to supports by arc spot welds, arc seam welds, powder-actuated fasteners, and screws, side-lap fastening, the deck's role in a composite slab including shoring, concrete placement loads, and the sequence for shear studs welded through the deck, roof deck uplift attachment and FM Approval, openings and their reinforcement, pour stops, closures, and sump pans, placement and OSHA decking requirements, field cutting and coating repair, field inspection under the SDI quality standard, delivery and storage, and the warranty for the deck work.
- Steel Joists
Open-web steel joists and joist girders furnished by Steel Joist Institute member manufacturers under ANSI/SJI 100 and erected under ANSI/SJI 200. Covers K-series and KCS joists, LH-series and DLH-series long-span joists, G-series joist girders, and CJ-series composite joists. Addresses the delegated-design relationship between the Engineer of Record and the joist manufacturer, joist and erector qualification, chord and web steel selection, deflection and floor-vibration criteria, camber policy, bearing seat depth and end anchorage, bridging type and attachment, headers at framed openings, chord extensions, erection stability and erection bridging under OSHA 29 CFR 1926 Subpart R, erection tolerances, shop coating selection, field touch-up, and field inspection of joist work.
- Structural Steel Connections
The bolted and welded connections that join hot-rolled structural steel framing members into a load-carrying structure: simple shear connections, fully restrained and partially restrained moment connections, vertical and horizontal bracing connections and their gusset plates, column splices, and the steel side of column base plate connections. Covers the assignment of connection design responsibility under AISC 303, the joint condition (snug-tight, pretensioned, or slip-critical) for each connection class, high-strength bolt assemblies under ASTM F3125 and their finish, the RCSC pretensioning methods and pre-installation verification, faying surface slip class and treatment, bolt hole types, the backing, weld tab, and access hole configurations at connection groove welds, load sharing between bolts and welds, the connection provisions AISC 341 imposes on the seismic force-resisting system, bolting inspection, and the handling of fastener assemblies.
- Structural Steel Framing
The hot-rolled structural steel frame of a building or structure designed by the Engineer of Record under ANSI/AISC 360: wide-flange beams, girders, and columns, hollow structural sections and pipe used as columns, braces, and beams, channels, angles, tees, plates, and bars, built-up members, crane runway beams, and the headed shear stud connectors, stiffeners, column base plates, and stabilizer plates furnished with them. Covers the material grade for each shape family, the material provisions the seismic force-resisting system imposes on members, fabricator and erector qualification, shop and erection drawings, cutting, hole forming, straightening, cambering, and member marking, architecturally exposed structural steel categories, the shop coating system and its boundary with applied fireproofing and field finishes, erection planning, temporary bracing, column base setting, erection tolerances and the post-erection survey, field touch-up, delivery and storage, and the warranty for the structural steel.
- Welding Requirements
The project-wide welding quality program for all shop and field welding of structural carbon and low-alloy steel in building construction — base-metal and filler-metal qualification, process selection (SMAW, FCAW, GMAW, SAW, GTAW), prequalified and qualified WPS, welder and operator qualification, preheat and interpass control, joint preparation and fit-up, weld size and type selection, weld quality acceptance, and the full nondestructive examination (visual, MT, PT, UT, RT) program, including seismic demand-critical welds and protected zones per AWS D1.8 in SDC C through F. Issue as this general welding standard that the fabrication sections call up by reference.
Masonry
(7)
- Brick Masonry
specifying, selecting, and installing clay and shale brick masonry for structural and architectural applications in commercial, institutional, and residential construction. Covers solid facing brick, building brick, hollow brick, and thin brick veneer units across single-wythe veneer, cavity wall, multi-wythe solid, and reinforced assemblies, with associated accessory materials (ties, joint reinforcement, flashing, weeps, expansion-joint sealant). Applies to new exterior and interior brick veneer cladding, structural brick walls, and feature walls under both empirical and engineered (TMS 402) design.
- Cast Stone
supply and installation of architectural cast stone trim units (manufactured concrete simulating quarried stone) such as sills, copings, lintels, banding, water tables, quoins, keystones, door and window surrounds, base courses, and column caps and bases, on new and renovated commercial, institutional, and residential buildings. Covers wet-cast and vibratory dry-tamp production, mix design, physical performance, reinforcement, color and texture, anchorage, mortar and setting, and field handling.
- Common Work Results for Masonry
the shared materials, installation requirements, and quality provisions that apply across all unit masonry and masonry veneer on a project — mortar and grout materials and placement, accessories (ties, anchors, flashing, weep holes, joint reinforcement, joint fillers), embedded items, workmanship, construction tolerances, cold- and hot-weather protection, cleaning, and field quality control including special inspections. This parent umbrella flows down to all subordinate masonry sections and need not be repeated there. Applies to commercial, institutional, industrial, and residential unit masonry and masonry veneer work.
- Concrete Masonry Units
procurement and pre-installation verification of hollow and solid concrete masonry units (CMU) delivered to a project site — loadbearing units to ASTM C90, non-loadbearing partition units to ASTM C129, and concrete brick to ASTM C55 — covering weight class, cell geometry, face-shell and web dimensions, specialty shapes, exposed finishes, dimensional tolerances, strength, absorption, shrinkage, and plant/delivery sampling for commercial, institutional, industrial, and multi-unit residential masonry.
- Masonry Anchorage and Veneer
anchored masonry veneer systems (brick, CMU, and natural or manufactured stone) over structural backup substrates such as cold-formed steel stud framing, CMU, cast-in-place concrete, or wood framing on commercial, institutional, and multi-family buildings. Covers the full anchorage assembly: adjustable two-piece veneer anchors, corrugated and wire ties, joint-reinforcement anchors, shelf and base support angles, air-space and cavity geometry, base and shelf-angle flashing, weep systems, and corrosion protection by exposure zone. Applies to new construction and veneer replacement on Type I-V construction in all seismic and wind exposure categories.
- Masonry Mortar and Grout
Selection, specification, mixing, and placement of mortar and grout for new masonry and for repair/repointing on commercial, institutional, and residential projects. Covers portland cement-lime, masonry cement, mortar cement, and pre-blended mortars per ASTM C270, and fine, coarse, and self-consolidating grouts per ASTM C476, including proportion and property methods, weather requirements, mockups, joint tooling, grout lifts and consolidation, and field QC.
- Unit Masonry
The assembled unit masonry wall. Load-bearing walls, shear walls, non-load-bearing partitions, composite and multi-wythe walls, the masonry backup wythe of a cavity wall, and pilasters and piers, built from concrete masonry units alone or from concrete masonry units combined with clay brick. Covers the assembly design values (specified masonry compressive strength, the unit and grout strengths that follow from it, and the mortar type for each wall class), grouting extent and the cells that receive it, bar reinforcement and joint reinforcement, corrosion protection of embedded metal, wythe ties and intersecting-wall connections, bond beams and lintels, bond pattern, bedding, and joint profile, control and expansion joints in the assembly, the prescriptive seismic detailing the seismic design category invokes, bracing of walls under construction, tolerances tightened for exposed work, and the strength verification and special inspection program.
- Glued-Laminated Timber
design, specification, procurement, and installation of structural glued-laminated timber (glulam) used as primary framing — horizontal beams and girders, vertical columns, and curved or shaped members (arches, Tudor frames, pitched and tapered members) — on commercial, institutional, industrial, and heavy-timber residential projects, including new timber-framed buildings, exposed heavy-timber systems, post-and-beam additions, and structural renovation. Covers stress-class and appearance-grade selection, camber, preservative treatment, end-grain sealing, bearing and connection detailing, and third-party certification.
- Mass Timber
Engineered mass timber structural elements - cross-laminated timber (CLT), structural glued-laminated timber (glulam), nail-laminated timber (NLT), dowel-laminated timber (DLT), and mass plywood panels (MPP) - used as floor, roof, wall, beam, and column members in Type IV-A, IV-B, and IV-C construction.
- Pre-Engineered Wood Roof Trusses
Factory-fabricated, metal-plate-connected (MPC) wood roof trusses for light-frame residential and low-rise commercial construction — king-post, Fink/W, Howe, Fan, scissors/vaulted, mono, attic, hip/hip-girder, and parallel-chord profiles spanning roughly 20-80 ft at 12, 16, or 24 in. o.c. in IBC Type III/V and IRC-governed buildings. Covers sealed truss design drawings, lumber and connector-plate specification, bearing, uplift tie-downs, temporary construction bracing, and permanent lateral restraint and diagonal bracing.
- Rough Carpentry
Non-finish structural and utility wood framing and blocking. Covers dimension lumber framing (studs, plates, sills, joists, rafters, headers, ledgers); species, grade, and grade stamps under an ALSC-accredited grading agency and the National Grading Rule; design values per the AWC NDS; moisture content (S-DRY / MC19 / KD); wall, roof, and floor sheathing in plywood (DOC PS 1) and OSB (DOC PS 2) with APA span ratings and Exposure 1 bond classification; wood structural panel attachment and nailing; rooftop blocking, nailers, cant strips, curbs, and concealed wood grounds and furring; pressure-preservative-treated wood per the AWPA Use Category System and the IBC locations that require it; fire-retardant-treated (FRT) wood for interior Type III, IV, and V applications; and corrosion-resistant fasteners and metal framing connectors (joist hangers, framing anchors, post bases) compatible with treated wood and exterior service.
- Special Inspections and Structural Testing
Defining the IBC Chapter 17 quality-assurance program for a permitted building project: the Statement of Special Inspections, approval of an independent inspection agency, inspector qualifications, continuous versus periodic designations, and the field testing and final-report requirements for concrete, structural steel, masonry, compacted fill, deep foundations, high-strength bolting, and welding.
- Wood Light Framing
Structural framing of load-bearing walls, floors, roofs, and their connections built from dimensional sawn lumber (nominal 2 in. to 4 in. thick) in platform- or balloon-frame wood buildings (IBC Type III and Type V). Covers studs, joists, rafters, headers, beams, blocking, bridging, ledgers, rim boards, sill plates, sill anchor bolts, hold-downs, and nailed or screwed framing connections, by either the prescriptive conventional path (IBC 2308 / IRC Chapter 6) or full NDS engineering.
- Wood Structural Panel Sheathing
Supply and installation of APA-rated wood structural panels (OSB and plywood) used as roof, wall, and floor (subfloor) sheathing in wood-framed buildings of all occupancy types, where panels carry the lateral load path (shear walls and horizontal diaphragms), distribute gravity loads, and serve as the substrate for the air/moisture barrier. Covers panel selection by span rating, performance category, exposure/bond classification, grade, thickness, fastening schedule, edge treatment, and acceptance criteria.
Sitework
- Aggregate Base Course
Aggregate base course (ABC) for commercial, institutional, and industrial projects covering the placement, compaction, and quality control of crushed stone or processed graded aggregate used as the structural sub-base or base course beneath flexible (asphalt) and rigid (concrete) pavements, slabs-on-grade, building floor systems, exterior hardscape, equipment pads, and similar site improvements. Covers material classification and gradation, subgrade acceptance, geotextile separation where soft subgrades are encountered, lift placement, moisture conditioning, compaction, proof rolling, surface tolerances, and field testing. Intended to be read alongside the geotechnical investigation report, the civil grading drawings, and the structural or pavement section details, all of which govern design-specific values such as base thickness, target density, and material class.
- Asphalt Paving
Dense-graded hot-mix asphalt flexible pavement for commercial, institutional, industrial, and multi-family site work, including parking lots, drive lanes, loading and service areas, fire lanes, and private site roadways, placed on an accepted aggregate base, a chemically stabilized layer, or a reclaimed base. Covers adoption of the state DOT specification by reference as an alternative to the project-written requirements, the design traffic level and the course thicknesses the pavement design hands to the paving contractor, aggregate quality, performance-graded binder, reclaimed asphalt pavement and shingles, Superpave and Marshall mixture design and the volumetric criteria, warm-mix asphalt, prime and tack coats, plant production and hauling, weather limits, placement, lift thickness, compaction, joints, edges, paving over a geosynthetic interlayer, full-depth patching and reconstruction of an existing asphalt pavement, the asphalt courses over a full-depth reclaimed base, and acceptance for density, thickness, smoothness, and mixture conformance. Read alongside the civil grading and paving drawings and the pavement design in the geotechnical report, which carry the pavement section, the course thicknesses, the binder grade, and the design traffic the datasheet fields of this standard defer to them.
- Cast-in-Place Site Concrete Structures
The cast-in-place reinforced concrete structures of the site that do not hold water by design: drainage headwalls, endwalls, and wingwalls with their aprons and cutoff walls; cast-in-place inlets, catch basins, junction chambers, diversion structures, and outlet control structures; cast-in-place stormwater detention vaults designed under ACI 318; cast-in-place electrical and communications utility vaults; cast-in-place collars, adjustment rings, and base slabs on precast units; trench walls, channel linings, and energy dissipators; and the bases of poles, posts, and signs where the standard that furnishes the pole or sign does not govern its base. A layer read with Cast In Place Concrete, Concrete Reinforcement, Concrete Formwork, Concrete Curing And Finishing, and Concrete Joints And Waterstops: it adds only what a site structure adds, the exposure classes of concrete that lives outdoors in soil and runoff, the strength of site structure concrete, casting against earth, form ties and waterstops below groundwater, the forming and sealing of pipe and conduit penetrations, frame seats, steps, and the anchorage of gates and hardware, the geometry particular to headwalls and chambers, the items cast into a utility vault, the joints in aprons and slabs not under hydrostatic pressure, surface protection, dewatering and flotation, the strength a wall needs before it is backfilled, and the warranty.
- Concrete Paving, Curbs, and Sidewalks
Site cast-in-place concrete flatwork and pavements for commercial, institutional, and industrial projects, including exterior vehicular pavements (parking stalls, drive lanes, loading and service areas), sidewalks and walkways, curbs and curb-and-gutter (cast-in-place and slip-formed/extruded), integral curbs, concrete aprons and pads at dumpster and loading areas, ADA curb ramps and the detectable warning surfaces at them. Covers subgrade and aggregate base coordination, concrete mixture and durability (air entrainment for freeze-thaw and deicer exposure), slab thickness, reinforcement (welded wire, dowels at construction joints, tie bars at longitudinal joints), jointing (contraction/control sawcutting timing and depth, isolation joints, construction joints) and joint sealing, finishing (broom and optional exposed aggregate), curing and curing compounds, flatwork tolerances, ADA running and cross-slope limits for walks and ramps, and cold- and hot-weather concreting. Intended to be read alongside the civil grading and paving drawings and the geotechnical report, which govern the pavement section, thicknesses, limits, grades, jointing plan, and drainage.
- Earthwork
Mass and structural earthwork for commercial, institutional, industrial, and multi-family building sites, from the cleared and demolished condition through placement of fill and acceptance of the subgrade. Covers excavation to the lines and grades of the grading and foundation drawings, classification of excavated material and rock removal, removal and replacement of unsuitable material, foundation and trench excavation, protection of workers and of adjacent structures in ordinary excavations, routine groundwater control by sump pumping, the fill classes (structural fill, free-draining granular fill, general site fill, recycled concrete aggregate, controlled low-strength material) and their sources, lift placement, moisture conditioning, compaction targets by use, backfill against structures and walls, trench backfill above the pipe zone, backfill of cavities and voids, proof rolling and subgrade acceptance, subgrade stabilization where proof rolling fails, field density testing and acceptance, frozen-ground and wet-weather restrictions, and the disposition of surplus and the sourcing of borrow. Read alongside the geotechnical investigation report and the civil grading drawings, which carry the project-specific values this standard defers to them.
- Erosion and Sediment Control
Construction-phase erosion prevention and sediment control for land-disturbing activities on commercial, institutional, and industrial building projects, including implementation of the project Stormwater Pollution Prevention Plan (SWPPP) under the EPA Construction General Permit or the applicable state NPDES stormwater permit. Covers perimeter sediment controls (silt fence, fiber rolls and wattles, compost socks), storm inlet protection, the stabilized construction entrance and wheel wash, sediment traps and sediment basins, check dams, temporary and permanent soil stabilization (temporary and permanent seeding, hydroseeding, mulch, rolled erosion control products and turf reinforcement mats), dust control, dewatering sediment controls, concrete washout, BMP inspection and maintenance, construction sequencing and phasing, and final stabilization and permit termination. Intended to be read alongside the project SWPPP and the civil erosion control plan, which carry the project-specific BMP locations and the stabilization schedule.
- Excavation Support and Dewatering
temporary and permanent excavation support systems and groundwater control for deep excavations (deeper than 5 ft, or in soil and groundwater conditions requiring engineered protective systems) on commercial, institutional, industrial, and civil projects. Covers soldier pile and lagging, sheet piling, secant and tangent pile walls, soil-mixed walls, slurry (diaphragm) walls, soil nail walls, internal bracing, tieback ground anchors and their testing, trench boxes and shields, and dewatering (wellpoint, deep well, eductor, sump pumping), together with instrumentation, monitoring, discharge permitting, and protection of adjacent structures and utilities.
- Fencing and Gates
Site perimeter, security, and screening fencing and the gates in it, for commercial, institutional, and industrial projects. Covers chain-link fence fabric, framework, rails, tension wire and fittings; ornamental tubular picket fence in galvanized steel, non-galvanized steel, and aluminum; welded wire mesh fence; barbed wire and barbed tape toppings; screening and privacy infill; posts, concrete footings, and alternative post-setting methods; swing, horizontal slide, vertical lift, and vertical pivot gates; pedestrian gates including those on an accessible route; automated vehicular gate operators listed to UL 325; gate construction to ASTM F2200; entrapment protection; gate locking and access-control rough-in; grounding and bonding; and fences that serve as a swimming pool or spa barrier.
- Geosynthetics and Geotextiles
Geosynthetic materials placed in civil site construction on commercial, institutional, industrial, and multi-family projects, selected by the function each performs: separation of a fine-grained subgrade from an aggregate layer, stabilization of a soft subgrade beneath a working platform or base, filtration where a geotextile stands alone as the filter or forms the filter face of a geocomposite, in-plane subsurface drainage through a drainage geocomposite, base reinforcement with a geogrid, a paving fabric or paving grid interlayer beneath an asphalt course, and bentonite containment with a geosynthetic clay liner. Covers woven and nonwoven geotextiles, extruded and coated geogrids, geonet and cuspated-core drainage geocomposites, asphalt interlayers, and geosynthetic clay liners; property selection by AASHTO M 288 function and survivability class or by the project design; certified test reports and conformance; placement, overlap, seaming, cover, and exposure limits; and the material and placement of geosynthetics that other sitework standards call for by reference. Read alongside the geotechnical investigation report and the civil drawings, which carry the subgrade strength, the pavement design, and the drainage design that the derived and deferred fields of this standard rest on.
- Geotechnical Instrumentation and Monitoring
Selection, installation, baseline reading, operation, data management, and decommissioning of field instruments that observe ground, groundwater, and structure behavior during and after earthwork, excavation support, deep foundation installation, and earth retention. Covers inclinometers, vibrating-wire and standpipe piezometers, settlement monuments and liquid-level systems, extensometers, tiltmeters, crack meters, strain gauges, load cells, total pressure cells, and automated data acquisition systems with telemetry and alert notification for braced excavations, sheetpile and soldier-pile walls, slurry and tieback walls, MSE walls, embankments, slope stabilization, and tunneling influence zones.
- Ground Improvement (Aggregate Piers and Soil Mixing)
Ground improvement of soft, loose, or otherwise inadequate native soils prior to placing shallow foundations, slabs-on-grade, embankments, or pavement subgrades, using aggregate piers (rammed aggregate piers, vibro stone columns, vibro replacement), deep and mass soil mixing (DSM), or jet grouting to increase bearing capacity, reduce settlement, and improve liquefaction resistance. Covers the design-build specialty subcontractor scope (site investigation, design, installation, and load testing) for granular reinforcement and cementitious stabilization methods on commercial, industrial, infrastructure, and institutional projects where native soils cannot directly support shallow foundations but mass excavation/replacement or driven deep foundations are cost-prohibitive.
- Hazardous Material Abatement
survey, identification, notification, containment, removal, transport, and disposal of regulated hazardous materials in existing buildings undergoing renovation, alteration, or demolition — primarily asbestos-containing materials (ACM), lead-based paint (LBP), and PCB-containing caulk, sealants, and glazing compounds — on commercial, institutional, industrial, and multi-family residential (4+ unit) projects where a pre-demolition hazmat survey is required or regulated materials are confirmed present.
- Landscape Irrigation
Underground automatic landscape irrigation on commercial, institutional, industrial, campus, and multi-family sites, from the irrigation point of connection through the mainline, isolation and zone control valves, the master valve and flow sensor, lateral piping, spray bodies and gear-driven rotors, drip and subsurface drip, the controller with its rain, freeze, flow, and soil moisture sensors and its field wiring, sleeving under paving, irrigation-specific pipe zone and cover requirements, hydrostatic and coverage testing, controller programming, winterization, record documents, warranty, and spare parts. Read alongside the irrigation plan, legend, zone schedule, and details, which carry the head and emitter layout, spacing, nozzle assignments, zone flows and pressures, pipe sizes, and routing this standard defers to them.
- Pavement Markings and Site Signage
Exterior pavement markings and site traffic and regulatory signage for commercial, institutional, and industrial site work, including parking lots, drive lanes, loading and service areas, fire lanes, and private site roadways. Covers marking material selection (waterborne traffic paint, hot-applied thermoplastic, preformed thermoplastic and preformed marking tape, and durable epoxy and methyl methacrylate cold-plastic markings) and where each material fits; retroreflective glass beads, intermixed and drop-on; marking colors, widths, and meanings per the FHWA Manual on Uniform Traffic Control Devices (MUTCD); parking stall layout, directional arrows, stop bars, crosswalks, and word and symbol legends; accessible (ADA) parking spaces, access aisles, the International Symbol of Accessibility, and accessible space counts; surface preparation and the cure age of new pavement before marking; site traffic and regulatory signs (stop, accessible parking, speed, and directional) with their MUTCD designations; sign sheeting retroreflectivity, sign substrate, posts and footings, and mounting height and lateral placement; and fire-lane markings and signage. Intended to be read alongside the civil site plan and the signing and striping plan, which carry the project-specific marking and sign locations, the stall layout, and the accessible parking count.
- Pavement Rehabilitation and Sealcoating
planning, specifying, and executing preservation and rehabilitation of existing asphalt surfaces on roadways, parking lots, driveways, and service areas - cold milling, hot-mix asphalt mill-and-overlay, thin overlays, crack cleaning/routing and sealing/filling, asphalt-emulsion or coal-tar sealcoating, slurry seal, microsurfacing, chip seal, and fog seal - including pre-treatment condition assessment (PCI per ASTM D6433), surface preparation, weather limits, and acceptance testing.
- Permeable Paving
Load-bearing pavement built to pass stormwater through or between its surface into an open-graded stone reservoir and from there into the native soil, an underdrain, or both, on commercial, institutional, industrial, campus, and multi-family sites: parking lots, drive aisles, service and loading areas, fire lanes and emergency access, plazas, walkways, and overflow parking, wherever the stormwater permit, the land-development ordinance, or the Owner's own runoff goal credits the pavement as a stormwater practice. Covers the four surface systems, pervious concrete, porous asphalt, permeable interlocking concrete pavers, and concrete grid pavers; the hydrologic mode of the section, full, partial, or no infiltration, as the decision every other selection follows from; the bedding, choker, and base courses; the open-graded reservoir and its void ratio; the separation geotextile and the geomembrane liner of a no-infiltration section; the underdrain, its raised outlet, and the drawdown of the reservoir; edge restraints; observation wells and cleanouts; the subgrade infiltration basis and its protection from compaction and sediment through construction; surface infiltration acceptance testing; and turnover of the pavement to the party that will vacuum-sweep it. Read alongside the stormwater management report and the civil grading and paving drawings, which carry the reservoir depth, the underdrain and outlet elevations, the surface grades, and the limits of each pavement cell, and alongside the geotechnical investigation report, which carries the subgrade infiltration rate the hydrologic mode rests on.
- Planting and Soil Preparation
Exterior landscape planting of trees, shrubs, ground covers, and turf, together with the soil preparation, backfill, mulching, staking, establishment, and warranty work that supports them, on building sites, campuses, parks, and roadside or urban hardscape contexts.
- Sanitary Sewer Systems (Site)
The site sanitary sewer on commercial, institutional, industrial, campus, and multi-family sites, from the point five feet outside the building foundation wall where the building drain ends to the connection at the public sewer, the on-site treatment facility, or the headworks of a treatment plant. Covers the building sewer and the gravity collection mains and laterals in solid-wall and profile-wall PVC, polyethylene, ductile iron, vitrified clay, and reinforced concrete; the service connections to new and existing mains; lateral cleanouts; sanitary manholes in precast concrete, fiberglass, polymer concrete, and cast-in-place concrete with their joints, connectors, benches, drops, and corrosion protection; frames, covers, grade adjustment, and inflow protection; separation from water mains; trench foundation, pipe embedment, and backfill within the pipe zone; pipe laying, jointing, and connection to existing sewers; the sewage force main from the discharge connection of a lift station to its receiving manhole, with its pressure class, thrust restraint, air valves, cleaning access, and discharge; and the leakage, vacuum, deflection, pressure, and video testing that proves the system before acceptance.
- Selective Demolition
Planned, engineered removal of specific building components, systems, or portions of an existing structure while preserving and protecting adjacent work that remains in service. Applies to interior and exterior renovation, tenant improvements, adaptive reuse, additions, systems replacement, historic rehabilitation, and phased work in occupied buildings within a defined limit-of-work boundary, including pre-demolition engineering survey, utility identification and cutoff, temporary shoring and bracing, dust/noise/vibration control, debris removal, and protection of construction remaining.
- Site Clearing
opening land-preparation operations on commercial, institutional, industrial, residential-subdivision, roadway, and utility-corridor projects, before grading or construction begins. Covers clearing of above-ground vegetation, grubbing of stumps and roots below subgrade, topsoil stripping and stockpiling, protection of trees and features designated to remain, disposal or on-site management of cleared material, and demolition of minor above-grade site features.
- Site Furnishings and Bollards
Exterior site furnishings (benches, picnic tables, waste and recycling receptacles, bike racks, planters, drinking fountains) and bollards (decorative/architectural, ASTM F3016 low-speed storefront/pedestrian, and ASTM F2656 high-security vehicle-barrier) for commercial, institutional, civic, and multi-family residential site packages - plazas, parks, streetscapes, courtyards, transit areas, and campuses. Covers materials, finishes, anchorage (surface-mounted, embedded, removable, retractable), spacing layout, and ADA-compliant clearances for new construction and renovation.
- Site Grading and Subgrade Preparation
Rough and finish grading of site surfaces — building pads, pavement subgrades, lawn and landscape areas, swales, berms, and drainage courses — from completion of mass earthwork through final subgrade preparation ready to receive aggregate base, slab-on-grade, pavement, or topsoil. Covers topsoil stripping and stockpiling, cut/fill grading to design contours, proof-rolling, scarification and recompaction, moisture conditioning, select/structural fill under building pads, and fine grading to trade tolerances on commercial, institutional, industrial, and residential projects.
- Site Retaining Walls
Site retaining walls — segmental/SRW (gravity and geogrid-reinforced/MSE), cast-in-place cantilever, gravity (concrete, gabion, boulder), and modular block walls — for grade separation, slope stabilization, and site terracing on commercial, institutional, and industrial projects. Covers wall type selection, geotechnical and global stability requirements, the engineered-design threshold for tall or surcharged walls, materials (SRW units, concrete and reinforcing, geogrid, leveling pad, drainage aggregate, reinforced backfill, caps), the drainage system behind the wall, batter and embedment, surcharge loading, factors of safety, installation, and inspection.
- Site Utilities
Exterior underground wet and dry site utilities for commercial, institutional, and industrial building projects, beginning 5 feet outside the building footprint and extending to the point of connection at the public main, meter, or utility owner's facility. Covers the site domestic and fire water service and on-site water distribution (ductile iron and PVC pressure pipe, valves, hydrants, service fittings, thrust restraint), the site sanitary sewer (gravity collection mains and laterals, and pressurized force mains and low-pressure sewer), and the underground dry-utility infrastructure for electrical and telecommunications service (direct-buried and concrete-encased duct banks, conduit, and manholes/handholes). Also covers the common trenching, bedding, embedment, backfill, separation, tracer-wire and marking-tape locating, pressure and leakage testing, deflection and air testing, and water-main disinfection that apply across these systems.
- Site Water Distribution Piping
private on-site pressurized water distribution piping that carries potable, reclaimed, or dual-service water across a site - from the point of connection at the public main, meter vault, or utility facility, through site mains, laterals, and branch services, to roughly 5 feet outside the building. Covers pipe selection (ductile iron, PVC, HDPE), pressure class and wall thickness, fittings, mechanical and restrained joints, isolation valves and service appurtenances, thrust restraint, bedding and embedment in the pressure zone, tracer wire, utility separation, hydrostatic and leakage testing, and main disinfection.
- Soil Stabilization and Modification
in-place or plant-mixed chemical treatment of native subgrade soil and imported fill with lime, portland cement, fly ash, cement kiln dust, lime kiln dust, or blended cementitious binders to reduce plasticity and swell/shrink potential (modification) or to gain structural strength (stabilization). Covers pavement subgrade, slab-on-grade subgrade, embankment in moisture-sensitive soils, subbase beneath aggregate base or rigid pavement, and liner subgrade where shrink-swell governs, including lab mix design, binder delivery and storage, subgrade prep, spreading, mixing, compaction, curing, and acceptance testing.
- Soil Treatment for Termite Control
Pre-construction chemical soil treatment applied by a licensed pest control operator as an EPA-registered liquid termiticide barrier to protect new buildings from subterranean termite damage. Covers horizontal sub-slab barriers, vertical perimeter trench-and-rod barriers, and treatment at soil-contact penetrations for commercial, institutional, and residential projects in termite-infestation probability zones where soil treatment is required or specified under model building codes.
- Storm Drainage
Gravity storm sewer collection and conveyance on the site, for commercial, institutional, industrial, and multi-family projects. Covers storm sewer mains, laterals, and fittings in reinforced concrete, corrugated thermoplastic, solid-wall and profile-wall PVC, corrugated metal, and ductile iron; catch basins, curb and grate inlets, area drains, manholes, and junction structures; frames, grates, and covers; trench excavation, pipe embedment, and backfill within the pipe zone; outfall end treatments and scour protection; connection to an existing or municipal storm system; and the leakage, deflection, and video acceptance testing of the completed system.
- Stormwater Management and Detention Systems
Post-construction stormwater management facilities on commercial, institutional, industrial, campus, and multi-family sites, where the stormwater permit, the municipal separate storm sewer system program, or the land-development ordinance conditions approval on detention, retention, infiltration, or water-quality treatment of site runoff. Covers the facility itself and its outlet control: surface dry and extended detention basins, wet retention ponds, underground thermoplastic arch chamber beds, corrugated pipe storage, precast and cast-in-place concrete vaults, and modular plastic crate storage; the storage aggregate and its void ratio; the liner decision and geomembrane liners; the geotextile envelope; pretreatment forebays, isolator rows, and proprietary treatment devices with their verification basis; the outlet control structure with its orifices, weirs, trash racks, drawdown and spill-control provisions; emergency spillways; inspection ports and maintenance access; infiltration testing and the design infiltration rate; flotation resistance; installation, acceptance testing, the as-built storage verification, and turnover of the facility to the party that will maintain it.
- Structure Demolition
complete removal of entire above-grade structures — buildings, towers, silos, bridges, and other discrete structures — down to and including their foundation systems, on redevelopment or clearance sites. Covers engineering surveys, utility disconnection, protection of adjacent structures and the public, mechanical and explosive demolition methods, debris management and material diversion, and site restoration to a demolition-complete condition ready for subsequent earthwork.
- Subdrainage
Subsurface drainage systems installed as civil/sitework elements on commercial, institutional, industrial, and infrastructure projects — underslab interceptor/relief drains beneath large slabs on grade, pavement subgrade edge and blanket drains, retaining-wall and landscape relief drains, athletic field underdrains, upslope interceptor drains, and trench backfill drainage blankets. Covers perforated corrugated HDPE pipe, perforated PVC pipe, aggregate drainage envelopes, nonwoven geotextile filter fabric, geocomposite drainage panels, outlet fittings, cleanouts, and observation ports for new construction and remedial retrofit.
- Water Supply Wells
The drilled water supply well for a public water system, a water or wastewater treatment plant, or an industrial facility, from the well construction permit and the drilling through the casing, the annular seal, the screen, the filter pack, the development, the plumbness and alignment survey, the test pumping, the water quality sampling, the disinfection, and the wellhead completion, up to the well record the permanent pump is selected and set against, read with Common Work Results Process. Written for a public water supply source or a plant supply well, and applied to a private domestic or irrigation well where the drawings assign it, because the state well construction code holds every well to the same construction rules. Covers the drilling methods and the formation each suits, the pilot hole and reaming, formation sampling and sieve analysis, geophysical logging and the video survey, steel, stainless, and PVC casing and its joints, surface casing, neat cement and bentonite seals and their placement, screen type, material, slot, and setting, the filter pack and its placement, naturally developed and filter-packed completions, development by surging, air-lift, jetting, overpumping, and chemical aids and the criteria that end it, the step-drawdown and constant-rate tests with the temporary test pump, discharge and water level measurement, sand sampling, the test pumping report, the samples the primacy agency requires of a new source, disinfection under AWWA C654, the casing stickup, well seal, pitless unit, sounding tube, vent, and pad at the wellhead, the driller's log, the as-built well record and the state well completion report, the abandonment of a test hole or a failed well, and the protection of the well during construction.
Mechanical
Air Distribution
(33)
- Active and Passive Chilled Beams
Specification, selection, installation, and commissioning of active (ACB) and passive (PCB) chilled beam terminal units for sensible cooling and supplemental heating in commercial and institutional buildings (offices, higher education, non-critical healthcare, hotels, laboratories) served by chilled water and a dedicated outdoor air system; covers ceiling-recessed, ceiling-exposed, and multi-service configurations, condensation protection, and controls integration.
- Air Handling Units
Central station air handling units that condition air and deliver it through a field-installed duct distribution system, whether factory-assembled in shipping sections or field-erected from components. Covers indoor and outdoor units, constant-volume and variable-air-volume systems, single-zone and multiple-zone arrangements, mixed-air units and dedicated outdoor air units, and units serving commercial, institutional, industrial, healthcare, and laboratory occupancies.
- Air Terminal Units
Factory-fabricated air terminal units that meter primary air from a central air system into an individual thermal zone in commercial, institutional, healthcare, and industrial buildings. Covers single-duct, dual-duct, and bypass metering arrangements; variable-volume and constant-volume airflow control; pressure-independent and pressure-dependent control basis; parallel and series fan sections; hot water, steam, and electric reheat with their valves, actuators, and safety devices; casing construction and acoustic treatment; primary damper and actuator; primary airflow sensing; radiated and discharge sound; the zone controller, zone sensor, and building automation interface; factory testing; installation; and field airflow, functional, and acoustic verification.
- Computer Room Air Conditioning Units
Factory-assembled precision cooling units that hold the temperature and humidity of a data center, server room, network room, telecommunications room, or other space whose load is electronic equipment running year-round. Covers direct-expansion units rejecting heat to a remote air-cooled condenser, a water-cooled condenser, or a glycol drycooler, chilled water units served by a central plant, and dual-source units, in downflow, upflow, horizontal, in-row, and ceiling-mounted arrangements; the fans, compressors, coils, control valve, humidifier, dehumidification and reheat, filters, drain pan, and economizer section of the unit; the remote condenser or drycooler and pump package furnished with it; the unit controller, its sensing point, unit-to-unit teamwork, and its interface to the monitoring system; leak detection under and around the unit; rating under AHRI 1360 by the ASHRAE 127 method; factory testing, installation, startup, commissioning, warranty, and spare parts.
- Dedicated Outdoor Air Systems
Factory-assembled dedicated outdoor air units that condition 100% outdoor air to a controlled leaving air dew point and supply air temperature, independent of the sensible heating and cooling of the spaces they ventilate. Covers packaged outdoor and indoor units with direct-expansion, heat pump, or chilled water cooling; hot gas, wraparound, hydronic, and electric reheat; heat pump, gas-fired, electric, hydronic, and recovery-only heating; the air-to-air energy recovery section and its exhaust side; supply and exhaust fans; filtration; casing, drain pans, and curbs; the refrigerant, its safety group, and the detection provisions that go with mildly flammable refrigerants; the supply air temperature and dew point control strategy and the unit's interface to the building automation system and to the parallel sensible system; and the setting, connection, startup, and commissioning of the installed unit. Applies to units serving variable refrigerant flow, fan coil, water-source heat pump, chilled beam, and radiant systems, to units supplying laboratory make-up air, and to units delivering ventilation air directly to occupied spaces.
- Dust and Fume Collection Systems
Fixed industrial and laboratory-process dust collection and fume exhaust systems that capture airborne particulates, mists, vapors, or process fumes at the point of generation and convey them to air-cleaning equipment before discharge — manufacturing plants, fabrication and welding shops, metal-grinding areas, woodworking plants, and chemical and food-processing spaces. Covers capture hoods, conveying ductwork and air-moving fans, primary air-material separators (baghouses, cartridge collectors, cyclones, wet scrubbers, electrostatic precipitators), explosion-isolation and fire components in the exhaust stream, and system controls and monitoring, for both new systems and modifications to existing ones, including combustible and non-combustible streams.
- Energy Recovery Ventilators
Air-to-air energy recovery devices that transfer heat, and optionally moisture, between a building's outdoor (intake) air stream and its exhaust (relief) air stream to reduce the conditioning load imposed by code-required ventilation. Covers packaged rooftop, wall, and ceiling energy recovery ventilators (ERVs and heat recovery ventilators) with integral fans and controls; core-only energy recovery components installed in custom or field-built air handlers and dedicated outdoor air systems (rotary enthalpy and sensible wheels, fixed-plate sensible aluminum cross-flow cores, fixed-plate membrane enthalpy cores, heat-pipe assemblies, and runaround glycol coil loops); the recovery effectiveness, cross-leakage, and frost-control behavior that govern selection; the supply and exhaust fans where integral; filtration; casing; condensate management; and the controls integration including economizer bypass and demand-controlled modulation. Applicable to commercial, institutional, multifamily, and light-industrial buildings where exhaust-air energy recovery is mandated by the energy code or used to reduce ventilation load.
- Evaporative Coolers
Factory-assembled evaporative air coolers — direct, indirect, and two-stage (indirect/direct) — serving as primary or supplemental cooling in dry climates (outdoor design wet-bulb at or below 68°F / 20°C) for commercial, institutional, light-industrial, warehouse, and agricultural facilities. Covers rooftop, ground, and wall-mounted packaged units, central-station evaporative modules, and integral evaporative pre-cooling sections, including capacity, casing and media materials, water distribution, bleed-off and water management, controls integration, efficiency, and field commissioning, for new construction and retrofit where refrigerant cooling is absent or used only as backup.
- Fan-Coil Units
Factory-fabricated hydronic fan-coil units and blower coil units that recirculate room air across a chilled water coil, a heating water coil, or both to condition a single thermal zone from a central water plant. Covers 2-pipe and 4-pipe units with or without supplementary electric heat; horizontal and vertical arrangements; exposed cabinet, concealed, and recessed enclosures; floor, ceiling, and stacked high-rise riser types with their integral risers; the fan, motor, and speed control; filters; the drain pan and the condensate connection; the coil connection package and the control package as furnish decisions; AHRI 440 ratings and AHRI 350 and AHRI 260 sound ratings; installation, startup, warranty, and spare parts.
- Fire and Smoke Dampers
Specifying, selecting, installing, and acceptance-testing life-safety dampers at duct penetrations through fire-rated walls, floors, and partitions in commercial, institutional, and industrial buildings. Covers curtain-type and multi-blade fire dampers, smoke dampers, combination fire/smoke dampers, and corridor dampers; UL-listed static and dynamic assemblies; leakage class requirements; sleeve, access-door, and breakaway-connection details; and the initial and periodic inspection/testing regime under NFPA 80 and NFPA 105.
- Gas Detection Systems
Fixed gas detection equipment in buildings where code or safety mandates continuous or demand-based atmospheric monitoring — enclosed and semi-enclosed parking garages (CO and NO2 for occupant safety and ventilation demand control), refrigerant machinery rooms (refrigerant-concentration detection triggering emergency ventilation and alarms per ASHRAE 15), commercial kitchen and food-service mechanical rooms, and other occupied or semi-occupied mechanical spaces where NFPA 72, IBC, or the AHJ mandates system-type detectors. Covers single- and multi-gas transmitter/sensor heads, control panels and relay modules, audible/visual annunciators, and interlock wiring to ventilation or exhaust systems.
- Gas-Fired Radiant and Infrared Heaters
gas-fired high-intensity luminous (ceramic/box/spot) and low-intensity radiant tube heaters used as primary or supplemental heating in commercial and industrial high-bay spaces (warehouses, distribution centers, manufacturing floors, aircraft hangars, auto service bays, gymnasiums, loading docks) with ceilings 12 ft and above, where direct radiant delivery to occupants and surfaces is preferred over convective air heating; natural gas or propane, vented or unvented, overhead-, angle-, or wall-mounted.
- Heating and Cooling Coils
field-installed and replacement forced-circulation air-cooling and air-heating coils for commercial, institutional, and industrial HVAC systems — hydronic chilled water and hot water coils, standard and distributing (non-freeze) steam coils, direct-expansion refrigerant coils, and glycol runaround heat-recovery coils set in air handlers, fan coil units, unit ventilators, and inline duct sections, whether supplied with a unit or fabricated to retrofit an existing casing. Governs coil construction, AHRI 410 performance rating and certification, factory pressure testing, drain pan sizing and material, face velocity limits, and pull-out clearance.
- Humidifiers
Specifying packaged humidification equipment for ducted central air systems, air-handling units, and direct-space applications in commercial, institutional, healthcare, laboratory, cleanroom, museum, and data center projects. Covers isothermal (electrode, resistive-immersion, gas-fired, steam-to-steam, and direct steam injection) and adiabatic (high-pressure atomizing, ultrasonic, and wetted-media evaporative) humidifiers, their dispersion assemblies, water-quality coordination, controls, and safeties.
- HVAC Air Distribution Devices
Room-side air distribution devices that terminate a ducted or plenum air system at the boundary of an occupied space - supply outlets (square and rectangular face, round face, linear slot, swirl, displacement, light-fixture-integrated), return and exhaust inlets, and transfer openings, together with the frames, cores, integral dampers, and finishes furnished as part of the device. Covers the performance criteria that govern occupant comfort and acoustic acceptability (throw at 50, 100, and 150 fpm terminal velocities, ADPI, occupied-zone air speed, occupied-space sound level), device materials for dry, wet, and corrosive service, exposed finishes, security and anti-ligature construction, installation and support, and field balancing and verification. Applies to new construction and to renovation where devices are connected to a distribution system.
- HVAC Duct Accessories
specification, material selection, performance rating, and installation of duct accessories for commercial, institutional, healthcare, and industrial HVAC air distribution systems up to 10 in. w.g. — manual and motorized volume dampers (rectangular and round, opposed- and parallel-blade), backdraft dampers, duct access doors and panels, flexible duct connectors, turning vanes, duct silencers, duct test holes, and splitter dampers, in new construction and renovation.
- HVAC Ductwork
Metal and flexible ductwork for low-pressure, medium-pressure, and high-pressure HVAC air distribution systems in commercial, institutional, and industrial buildings. Covers rectangular, round, flat-oval, and flexible duct; pressure and seal classifications; gauge and reinforcement; fittings and turning vanes; duct liner and external insulation; sealants; fire and smoke dampers; access doors; hangers and supports; leakage testing; and field verification. Applies to new construction and major renovation of supply, return, exhaust, and outside-air distribution systems.
- HVAC Fans
General-purpose, field- or factory-installed air-moving equipment serving commercial, institutional, and light-industrial HVAC systems. Covers centrifugal fans (housed and plenum/plug type), axial fans (vaneaxial, tubeaxial, and propeller), inline (cabinet and tubular) fans, utility/SWSI exhaust fans, roof- and wall-mounted power ventilators (upblast and downblast), ceiling-mounted exhaust fans, and dedicated kitchen grease-exhaust fans. Addresses aerodynamic and sound rating and certification (AMCA 210 / 300 / 211 / 311), Fan Energy Index compliance under ASHRAE 90.1 (AMCA 208), AMCA construction class and drive arrangement, direct-drive and belt-drive selection, induction and electronically commutated (EC) motors, bearings, materials and finishes, spark-resistant construction for hazardous exhaust (AMCA 99), accessories, vibration isolation, and the electrical and controls interface to variable-frequency drives and the building automation system.
- HVAC Sound Attenuators
prefabricated in-duct sound attenuators, also called duct silencers, installed in supply, return, exhaust, outdoor-air, and relief ductwork to reduce fan and equipment noise reaching an occupied space, and in transfer ducts to reduce room-to-room cross-talk. This standard establishes the rating basis and test evidence the performance data must carry, the room noise criterion and space sound level estimation procedure the selection answers to, the attenuation credits the selection is allowed to take, the casing and acoustic media construction, the approach and flanking conditions that protect the rated performance in the field, and the post-installation verification that confirms it.
- Kitchen Exhaust Systems
Design and specification of commercial kitchen exhaust ventilation for food service in new construction and major renovation — Type I grease-laden hoods (wall-canopy, island, low-profile/proximity), grease ducts, grease-rated exhaust fans, grease collection and rooftop terminations; Type II heat-and-steam hoods for non-greasy appliances; makeup air systems (direct-fired, indirect-fired, or untempered); and demand-controlled kitchen ventilation (DCKV). Applies to restaurants, cafeterias, commissary and hospital kitchens, hotel banquet and correctional food service, and any commercial cooking operation subject to IMC Chapter 5 and NFPA 96.
- Laboratory Exhaust and Fume Hoods
specifying, selecting, installing, and verifying laboratory exhaust and chemical fume hood systems for spaces that generate hazardous chemical, biological, or radiological vapors — CAV and VAV chemical hoods, specialty hoods (perchloric acid, radioisotope, high-heat/digestion, distillation), ductless recirculating hoods, manifolded and dedicated exhaust systems, high-plume dilution fans, make-up air devices, airflow monitors, and sash controls. Typical projects: university research labs, K-12 science classrooms, hospital and clinic labs, pharmaceutical support labs, and analytical labs.
- Louvers and Dampers
Stationary exterior and interior louvers and the full range of air-control and life-safety dampers in commercial, institutional, and light-industrial buildings. Covers drainable-blade, storm-resistant (wind-driven-rain), sand-trap, acoustic, combination louver/damper, and penthouse/gooseneck louvers selected by free area and water-penetration class at the design intake velocity; air-control dampers (parallel- and opposed-blade) selected by AMCA 500-D leakage class; backdraft, gravity, and pressure-relief dampers; and the life-safety dampers required at rated barriers — fire dampers (UL 555), smoke dampers (UL 555S), combination fire/smoke dampers, and ceiling radiation dampers (UL 555C) — together with actuators, fusible and resettable links, sleeves, retaining angles, access, and the firestopping interface. Includes hurricane-zone (AMCA 540 / 550) and Florida/High-Velocity-Hurricane-Zone louver requirements and the AMCA Certified Ratings Program basis for ratings.
- Makeup Air Units
Dedicated air-handling units that condition and deliver 100% outdoor replacement air to offset large exhaust volumes in commercial, industrial, and institutional buildings - commercial kitchens, laboratories, spray-finishing booths, warehouses, manufacturing plants, and any occupancy where exhaust creates negative pressure. Covers packaged rooftop and indoor units (roughly 1,000 to 150,000 CFM) with direct gas-fired, indirect gas-fired, hot-water, steam, or electric heat; optional evaporative, DX, or chilled-water cooling; supply fans; mixing/recirculating dampers; and integral controls.
- Packaged Rooftop Units
Factory-assembled, self-contained packaged units with an integral direct-expansion refrigeration circuit, set on a roof curb and serving a field-installed duct distribution system. Covers cooling-only, gas-fired, electric resistance, hydronic, and reverse-cycle heat pump heating configurations; constant-volume, multi-speed, and variable-air-volume supply fans; air-side economizers, powered relief, minimum outdoor air control, demand-controlled ventilation, and integral exhaust air energy recovery; the cabinet, filtration, drain pan, and roof curb; the refrigerant, its safety group, and the detection and mitigation provisions that go with mildly flammable refrigerants; unit-mounted controls and their interface to the building automation system; and the setting, connection, startup, and balancing of the installed unit.
- Packaged Terminal Air Conditioners
self-contained through-the-wall PTAC (cooling plus resistance heat) and PTHP (reverse-cycle heat pump) chassis-and-sleeve assemblies providing room-level cooling, heating, and ventilation with independent zone control in hotels, motels, multifamily, dormitories, assisted living, and similar occupancies; new construction and replacement/retrofit.
- Radiant Heating and Cooling Panels
Hydronic radiant heating and cooling panels at ceilings, floors, and walls in commercial, institutional, and high-performance residential buildings - including prefabricated metal radiant ceiling panels, concealed above-drywall panels, in-floor PEX or copper systems, wall panels, and thermally active building surfaces (TABS). Covers system layout, water temperature design, dew-point protection controls, balancing, and commissioning for low-noise, draft-free sensible conditioning of offices, labs, healthcare, and hospitality spaces.
- Smoke Control Systems
Engineered mechanical smoke control systems triggered by code, including stairwell pressurization, elevator hoistway pressurization, zoned (floor-by-floor) smoke control, and atrium or large-volume mechanical exhaust, together with their dedicated fans, smoke and combination dampers, listed control panels, and firefighter's smoke control station.
- Split-System Air Conditioners and Heat Pumps
Specifying matched split-system unitary air conditioners and air-source heat pumps, including ducted split systems (outdoor condensing/heat-pump unit matched to an indoor air handler or coil) and single-zone ductless mini-split systems, serving residential, light-commercial, and small-zone applications.
- Terminal Heating Units
Factory-built terminal heating units that condition a single zone or localized area — hydronic, steam, and electric resistance unit heaters (propeller and blower/cabinet types), fin-tube radiation, convectors, electric baseboard, and electric force-flow heaters. Applies to vestibules, loading docks, stairwells, mechanical and electrical rooms, entries, and perimeter spaces.
- Unit Heaters
self-contained, fan-driven space heaters serving unconditioned or intermittently occupied spaces (garages, warehouses, loading docks, mechanical rooms, vestibules, hangars). Covers propeller-fan and cabinet/blower unit heaters with hot-water, steam, gas-fired (natural gas or propane), or electric heating elements, including selection, mounting, discharge orientation, controls, clearances to combustibles, and venting/combustion-air provisions for gas-fired units.
- Variable Air Volume Terminal Units
zone-level pressure-independent variable air volume terminal units metering primary air from a central variable-volume air system, covering single-duct cooling-only and reheat units, parallel and series fan-powered units, and dual-duct variable-volume units. This standard establishes the zone airflow setpoint basis, the ventilation compliance basis, the energy-standard reheat and fan-power limits, the zone operating modes, the system reset requests the unit generates, and the field verification that confirms all of it.
- Variable Refrigerant Flow (VRF) Systems
Variable refrigerant flow (VRF/VRV) air-conditioning and heat pump systems serving commercial, institutional, and multifamily buildings, in which one or more inverter-driven condensing units circulate refrigerant through a piped network to multiple indoor fan-coil units, each metered by an electronic expansion valve. Covers heat pump (cooling-or-heating) and heat recovery (simultaneous cooling and heating) systems, air-cooled and water-source (water-cooled) condensing units, ducted and non-ducted indoor unit types, branch controllers and refrigerant selector boxes, A2L refrigerant safety and leak detection, and coordination of a dedicated outdoor air system for ventilation.
- Water-Source Heat Pumps
unitary water-source heat pump (WSHP) equipment rated below 135,000 Btuh and the shared building water loop (water-loop heat pump systems) that ties the units together, including loop conditioning equipment (boiler and cooling tower or fluid cooler) and the circulating pump system. Applies to new construction and retrofit in commercial, multifamily residential, hospitality, institutional, and mixed-use buildings where independent zone heating and cooling without dedicated outdoor units is required (hotels, apartments, offices, schools, assisted living). Covers vertical, horizontal, console, and through-the-wall configurations, water-to-air and water-to-water units, loop temperature design, and ASHRAE 90.1 energy-code compliance.
Piping & Pumps
(17)
- Chilled and Condenser Water Piping
Central-plant chilled water (CHW) and condenser water (CW) distribution for commercial, institutional, industrial, campus, hospital, and data center cooling — large-diameter steel mains (4 in. through 36 in.) connecting water-cooled chillers to cooling towers and to air-side equipment. Covers plant headers, secondary/tertiary distribution, risers, buried/tunnel and above-grade installation, pre-insulated and field-insulated systems, header isolation/balancing/check valves, strainers, flow metering, expansion compensation, open-circuit corrosion control, condensation-control insulation, and pressure testing/flushing within ASME B31.9 limits (150 psig, below 200°F).
- Expansion Fittings and Loops for Piping
Selecting and installing devices and fabricated configurations that absorb thermal growth in mechanical piping - metallic bellows joints (single, tied, hinged, gimbal, pressure-balanced), slip/sleeve joints, rubber/elastomeric joints, ball-joint pairs, and fabricated expansion loops (U-loops, L-offsets, Z-offsets) - for hydronic, steam and condensate, and domestic hot-water recirculation systems, plus the anchors and guides integral to their function.
- Expansion Tanks and Air Separators
Pressurization and air management equipment for closed hydronic heating and cooling systems - diaphragm and bladder expansion tanks, open compression tanks, inline and tangential air separators, microbubble and combination air-and-dirt separators, and automatic air vents. Covers selection, sizing, pre-charge setting, fill-pressure coordination, location relative to the pump, and air-elimination train integration for closed loops from 15 to 300 psig and 32 to 240 °F (commercial HVAC, process and data center cooling, hot water recirculation).
- Facility Fuel-Oil Systems
The fuel-oil system that carries No. 2 diesel, biodiesel blends, and heating oil from the nozzles of the storage tanks to the supply and return connections of stationary engine-generators, oil-fired boilers, and other oil-burning equipment on commercial, institutional, industrial, data center, and utility projects. Covers the transfer pump set and its controller, the day-tank fill, overflow, and level logic, the fuel-oil system monitoring console where one is furnished, the supply, return, overflow, fill, and vent piping beyond the tank nozzles, the valves and safety devices in that piping, the leak detection of double-wall piping, transfer filtration and water separation, fuel polishing, tank and pipe heating for cold weather, the pressure testing, flushing, and functional testing of the assembled system, installation, warranty, and spare parts.
- Facility Liquefied-Petroleum and Fuel Gas Piping
interior natural gas and LP (propane/butane) fuel gas distribution piping inside and immediately serving commercial, institutional, and industrial buildings - from the building entry, utility meter/regulator set, or LP tank connection through to individual appliance connections. Covers piping materials (Schedule 40 steel, CSST, copper, buried PE), joints, pressure regulators, relief devices, shutoff valves, flexible appliance connectors, sizing and pressure-drop, bonding, and pressure testing at low (up to 2 psi) and medium (2-5 psi) interior pressures for boiler plants, commercial kitchens, laboratories, process heating, and standby generator fuel trains.
- Fuel Storage Tanks
Factory-built fuel storage tanks furnished as vessels for stationary fuel-burning equipment on commercial, institutional, industrial, data center, and utility projects: the aboveground diesel and fuel-oil tank listed to UL 142, UL 2080, UL 2085, UL 80, or UL 2258, the underground tank listed to UL 58 with UL 1746 corrosion protection or to UL 1316, the tank set in a below-grade vault listed to UL 2245, the generator sub-base tank as a vessel, the day tank as a vessel, and the ASME liquefied-petroleum-gas container that stores propane for an engine-generator, a boiler, or other on-site equipment under NFPA 58. Covers the listing and construction, the secondary containment, the overfill prevention and spill containment at the fill, the normal and emergency vent devices, the leak detection sensors, the level gauging, the corrosion protection, the anchorage and flotation restraint, the foundation interface, factory and field tightness testing, delivery, warranty, and spare parts. The scope ends at the tank nozzles and, for a propane container, at the outlet of the container service valve.
- General-Duty Valves for HVAC Piping
General-duty, non-control isolation, shutoff, and non-modulating throttling valves in HVAC piping — hot-water heating, chilled water, condenser water, steam and condensate, and dual-temperature hydronic circuits in commercial, institutional, and industrial buildings. Covers gate, globe, ball, butterfly, check, and plug valves, NPS 1/4 through NPS 12 and larger, in bronze, brass, cast iron, ductile iron, and steel, Class 125 through Class 300.
- Hangers and Supports for Mechanical Piping and Equipment
Selecting, specifying, and installing hangers, supports, anchors, guides, restraints, and structural attachments for mechanical piping (steel, copper, CPVC, PEX, glass, stainless) from cryogenic up to 750 °F, 1/2 in. through 24 in. and larger, and for floor- and structure-mounted mechanical equipment (pumps, boilers, heat exchangers, fan-coil units, condensing units, packaged skids). Covers rod sizing, structural attachments, trapeze assemblies, variable- and constant-spring supports, thermal anchors and guides, and seismic bracing per ASCE 7-22 Chapter 13 / IBC 2024, for new construction and renovation on projects of all sizes.
- HVAC Condensate Drainage Piping
Primary and secondary (overflow) condensate drainage piping serving HVAC cooling and dehumidification equipment — cooling coils, evaporator coils, packaged rooftop units, split-system air handlers, fan coil units, chilled beams, and dehumidifiers — in commercial, institutional, and industrial buildings, new construction or renovation. Covers pipe material and sizing, slope, support spacing, traps, condensate lift pumps, overflow protection, insulation, and termination at the point of disposal.
- HVAC Pumps
Rotodynamic (centrifugal) pumps that circulate water and water-glycol solutions for building heating, cooling, and heat-rejection service. Covers closed-loop heating hot water and chilled water pumps, open-loop condenser water pumps serving cooling towers and fluid coolers, condenser loops serving water-source heat pumps, and the vertical turbine pumps used where the supply level sits below the pump. Addresses the pump end, the driving motor, the baseplate or frame, the coupling, shaft sealing, vibration isolation, factory and field acceptance testing, and the coordination items that decide whether the installed pump reaches its certified curve.
- HVAC Water Treatment
The ongoing chemical and physical water treatment program for HVAC water systems in commercial, institutional, and industrial buildings. Covers closed hydronic loops (heating hot water, chilled water, dual-temperature, water-source and ground-source heat pump loops, and inhibited-glycol loops), open recirculating condenser water systems served by cooling towers and evaporative condensers, and steam and condensate systems at or below 150 psig. Addresses make-up water characterization, corrosion and scale inhibitor chemistry, biocide programs, cycles of concentration and bleed control, chemical feed and controller equipment, side-stream filtration, sample ports and routine monitoring, corrosion coupon reading, the Legionella risk-management documentation required under ANSI/ASHRAE 188, the service contract that sustains the program, and seasonal lay-up.
- Hydronic Piping
Closed-loop hydronic distribution piping for heating hot water (HHW), chilled water (CHW), dual-temperature water (DTW), and condenser water (CW) in commercial, institutional, and industrial buildings, within the ASME B31.9 building-services envelope (up to 160 psig and 250°F). Covers pipe material and wall selection by service and size band, joining methods, fittings and flanges, dissimilar-metal isolation, delivery and storage, piping installation and routing discipline, the interfaces to supports, expansion compensation, valves, specialties, insulation, identification, and system cleaning, and the structural pressure test that proves the installed system.
- Hydronic Specialties
The in-line devices that make a closed-loop hydronic distribution system balanceable, protected, readable, and serviceable, installed in heating hot water, chilled water, dual-temperature, and condenser water piping within the ASME B31.9 building-services envelope. Covers manual calibrated balancing valves, automatic flow-limiting valves, differential pressure control valves, pressure-independent control valves furnished complete with their actuator, Y-pattern and basket strainers, suction diffusers, triple-duty valves and pump discharge assemblies, flexible pipe connectors, chemical bypass feeders, makeup water fill assemblies and glycol makeup packages, system relief valves, pressure gauges, thermometers and thermowells, pressure and temperature test plugs, manual air vents and hose-end drain valves, and factory or field-assembled coil connection assemblies.
- Mechanical Insulation
Field-applied thermal insulation for mechanical piping, ductwork, and equipment in commercial, institutional, and light-industrial buildings. Covers insulation of heating hot water, steam, steam condensate, and other hot service piping; chilled water, dual-temperature, and other below-ambient service piping that requires a continuous vapor barrier; HVAC supply, return, outside-air, and exhaust ductwork (concealed and exposed, indoor and outdoor); and mechanical equipment such as tanks, breechings, pumps, and heat exchangers. Includes selection of insulation material by service (mineral or glass fiber, closed-cell elastomeric, rigid cellular phenolic, cellular glass, and calcium silicate for high temperature), insulation thickness by the adopted edition of ASHRAE 90.1, jacketing and vapor retarders (all-service jacket indoors, PVC fitting covers, metal jacket outdoors and in mechanical rooms), insulated pipe supports and protection shields, penetration coordination, and the condensation-control provisions that govern cold-service work.
- Refrigerant Piping
Field-installed refrigerant piping that interconnects the components of split-system air conditioners and heat pumps, variable refrigerant flow systems, direct-expansion coils, computer room units, and packaged equipment supplied with a field-piped condensing section. Covers tube material and temper, joining methods and brazing filler metal, braze purge, field-installed specialties, line routing, oil return, insulation and its vapor seal, supports and seismic restraint, penetrations and firestopping, refrigerant concentration limits and the detection and mitigation provisions that go with mildly flammable refrigerants, piping identification, and the pressure test, evacuation, decay test, and charging sequence that puts the system into service.
- Snow Melt Systems
Embedded radiant snow and ice melting in outdoor hardscape: walks, plazas, entrance aprons, exterior stairs and ramps, accessible routes, drives, loading dock approaches, and parking aprons, heated by hydronic tubing carrying an inhibited glycol solution or by electric heating cable or mat cast into concrete, placed in asphalt, or set beneath unit pavers. Covers the snow melting class and the design surface heat flux as the design basis, the slab-side hydronic circuit (tubing, spacing, circuit hydraulics, glycol type and concentration for the snow melt loop, and the manifolds), the electric heating element under NFPA 70 Article 426 with its ground-fault protection of equipment, the automatic and manual controls with their sensors, setpoints, and idle mode, the insulation beneath the heated pavement, embedment depth and attachment, testing before, during, and after the pavement is placed, and the record drawing of the circuit layout.
- Steam and Condensate Piping
Steam supply and condensate return distribution piping for institutional, campus, healthcare, industrial, and central-plant facilities, above-grade and underground, from the boiler outlet connections to the inlet flanges of terminal equipment (heat exchangers, unit heaters, steam coils, and process loads). Covers low-pressure (0-15 psig), medium-pressure (15-100 psig), and high-pressure (100-300 psig) service, including pipe materials and joining by pressure class, expansion compensation, drip legs and steam traps, condensate receivers and pumps, pressure-reducing stations, flash tanks, valves, system insulation requirements, slope, and hydrostatic testing.
Heating & Cooling Plant
(7)
- Air-Cooled Condensing Units
Remote outdoor air-cooled condensing units (ACCUs) in split direct-expansion (DX) systems from roughly 1.5 to 130+ tons, where the evaporator is a physically separate fan-coil, DX air handler, or process coil joined by field refrigerant piping. Covers scroll, reciprocating, and screw compressors; single- and dual-circuit units; HFC/HFO/A2L refrigerants; rooftop, pad, and wall-bracket installations on commercial, light-industrial, retail, and server-room occupancies, including heat-pump units in cooling mode.
- Boilers
Packaged heating boilers that generate hot water or low-pressure steam for building space heating and for heating loops that serve coils, heat exchangers, and indirect equipment, in commercial, institutional, and industrial buildings, constructed and stamped to ASME BPVC Section IV. Covers gas-fired, oil-fired, dual-fuel, and electric boilers; condensing and non-condensing combustion; fire-tube, water-tube, sectional, and finned-tube heat exchangers; single and multiple-boiler plants; the pressure vessel with its trim, relief valve, low-water cutoffs, and limit controls; the burner, the fuel train downstream of the appliance shutoff valve, and burner management; combustion air, flue venting, breeching, and draft control at the boiler; flue gas condensate neutralization; the boiler control interface to the building automation system; factory testing, startup, and field testing; anchorage; warranty; and spare parts.
- Chillers
Factory-assembled vapor-compression liquid chillers that produce chilled water or a chilled water-glycol solution for building cooling and for process cooling in the same temperature range. Covers centrifugal, screw, scroll, and reciprocating compressor machines across the full commercial and institutional capacity range, with water-cooled, air-cooled, evaporatively cooled, and remote-condenser heat rejection. Addresses the compressor and its drive, the evaporator and condenser pressure vessels, the refrigerant circuit and its safety devices, the unit controller and its interface to the building automation system, the integral power and starting equipment, factory and field acceptance testing, and the setting, clearance, and connection items that decide whether the installed machine reaches its certified rating.
- Commercial Refrigeration Equipment
Selecting walk-in coolers and freezers (prefabricated modular panel systems and self-contained units), reach-in refrigerators and freezers, refrigerated display cases, under-counter and prep-table refrigeration, and packaged self-contained refrigeration systems for food service, healthcare, grocery, cold-storage, and laboratory facilities. Covers the refrigeration system, insulated panel enclosure, doors and hardware, controls, and DOE energy-efficiency compliance for maintained temperatures from roughly +55°F down to −40°F.
- Cooling Towers
Open-circuit and closed-circuit (fluid cooler) evaporative heat-rejection equipment for HVAC condenser water systems serving water-cooled chillers, water-source heat pump loops, and process cooling in commercial, institutional, and industrial buildings. Covers field-erected and factory-assembled (packaged) towers; induced-draft and forced-draft configurations; counterflow and crossflow arrangements; galvanized steel, stainless steel, and fiberglass (FRP/HDPE) construction; axial and centrifugal fans with constant-speed, two-speed, and variable-speed drives. Applicable from small rooftop packaged towers through large multi-cell field-erected installations.
- Furnaces
Gas-fired warm-air (central forced-air) furnaces serving as primary heating equipment in small commercial, light-industrial, and institutional buildings, generally up to 225,000 Btu/hr input. Covers upflow, downflow/counterflow, and horizontal cabinet furnaces; non-condensing (80% AFUE) and condensing (90%+ AFUE) types; natural gas and propane firing; standing-pilot and electronic (hot-surface or direct-spark) ignition; single-stage, two-stage, and modulating burner arrangements; all NFPA 54/IFGC vent categories (I, III, IV); and accessories furnished with the furnace (filters, integral controls, ignition and safety systems, matched cooling-coil cabinets).
- Heat Exchangers
Liquid-to-liquid heat exchangers serving building HVAC and plumbing systems, including gasketed plate-and-frame, brazed-plate, and shell-and-tube units for hydronic heating and cooling, steam-to-water heating, domestic water heating and preheat, glycol/water heat recovery, and pressure or thermal isolation between system circuits.
Controls & Testing
(6)
- Building Automation System
Networked direct digital control (DDC) systems that supervise and execute control of HVAC and ancillary mechanical building systems. Covers the management, supervisory, field controller, and field bus layers; controller and network conformance; operator workstation and graphics; scheduling, alarming, and trending; field sensors and control actuators; equipment integration points; the operational technology cybersecurity baseline; installation, commissioning, and closeout. Applicable to new construction, whole-system replacement, and expansion of an existing control system.
- HVAC Instrumentation and Control Devices
The field-device layer of a building automation system: the sensors, transmitters, switches, thermostats, and actuators wired or networked to the field controllers that execute HVAC sequences of operation. Covers space sensors and thermostats; temperature sensor assemblies with probes, averaging elements, thermowells, and radiation shields; humidity, carbon dioxide, and indoor air quality sensors; pressure transmitters and switches; equipment status, flow-proving, low-temperature, and condensate overflow switches; occupancy signal sources for HVAC; airflow measurement station hardware; water leak detectors and interposing relays; automatic control valves for hydronic and steam coils; electric damper and valve actuators; and pneumatic control devices where a pneumatic system is retained. Addresses supply and signal interface, wireless sensor policy, enclosure ratings by location, device-level acceptance testing, and spares, for new construction, whole-system replacement, and expansion of an existing control system.
- HVAC Variable Frequency Drives
Separately procured pulse width modulated variable frequency drives rated 600 V and below, controlling three-phase AC induction motors on HVAC air and hydronic equipment — supply, return, and exhaust fans, chilled water, condenser water, and hot water pumps, and cooling tower fans. Covers drive ratings, enclosure and cooling selection, harmonic performance, bypass and disconnecting means, motor and cable compatibility, protective functions, building automation integration, testing, and installation for drives in mechanical rooms, electrical rooms, penthouses, and outdoor locations.
- Hydronic System Cleaning and Flushing
The one-time preparation of a hydronic system's wetted interior between the piping pressure test and the start of the ongoing water treatment program, performed by the installing contractor on new systems and on extensions of existing systems in commercial, institutional, and industrial buildings. Covers the fill and the fill water baseline, the chemical cleaning step where one is selected, high-velocity flushing with its velocity calculation, flush pump, passes, and sampling, the protection and bypassing of coils, control valves, heat exchangers, and plant equipment during the flush, flush acceptance by measurement (clarity, turbidity, pH, conductivity, iron, suspended solids), disposal of the flush water and spent cleaner, passivation of the cleaned metal with the inhibitor chemistry of the ongoing program, installation of the corrosion coupon rack, the initial glycol charge where the system carries glycol, the signed cleaning, flushing, and passivation report that releases the system to balancing, startup, and treatment, and the flushing of the field piping of open condenser water systems. Applies to heating hot water, chilled water, dual-temperature, water-source and ground-source heat pump, closed-circuit condenser, inhibited-glycol, snow melt, and runaround loops in any pipe material and at any size.
- Testing, Adjusting, and Balancing for HVAC
Independent third-party testing, adjusting, and balancing (TAB) of HVAC air and hydronic systems for new construction and major renovation of commercial, institutional, and industrial buildings. Covers TAB agency and personnel qualifications; instrument selection and calibration; preliminary, full, and final TAB reports; air-side procedures (duct traverse, terminal device measurement, outdoor air verification, fan curve verification); hydronic procedures (flow station readings, coil balancing valve adjustment, pump curve verification); sound and vibration spot checks; deficiency reporting back to the installing contractors; and seasonal re-balance work. TAB shall conform to NEBB Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems (current edition), AABC National Standards for Total System Balance (current edition), or ASHRAE 111, as selected by the Engineer.
- Total Building Commissioning
The commissioning process for the mechanical, electrical, plumbing, life-safety, enclosure, and specialty systems of a new building or a major renovation, run under ANSI/ASHRAE/IES 202 and ASHRAE Guideline 0, with ASHRAE Guideline 1.1 for the HVAC&R systems and the commissioning requirements of the adopted energy code where they apply. Covers the commissioning authority, its qualifications, its engagement and its independence, the Owner's Project Requirements and the Basis of Design and their review, the commissioning plan, the design-phase reviews and the review of submittals for commissioned systems, the construction checklists, the format and conduct of functional performance tests, the integrated systems test and the integrated testing agent where NFPA 4 applies, the issues log, the seasonal and deferred tests, the verification of operator training, the systems manual, the progress and final commissioning reports and their formats, the warranty-period review, and monitoring-based commissioning where it is included. Carries the decision of which system families are commissioned, and admits building enclosure commissioning under ASTM E2813 as one of them.
- Common Work Results for Mechanical
The umbrella standard for the mechanical discipline, read together with every HVAC equipment, piping, ductwork, and controls standard on a project. Declares the governing mechanical, building, and energy code basis once; states the site conditions, submittal procedures, trade coordination, maintenance access, pipe sleeve and penetration provisions, electrical interface and division of responsibility, startup and acceptance sequence, temporary-use policy, delivery and protection, cutting and patching, warranty, and spare-parts provisions that the mechanical sections inherit rather than restate. Carries no product requirements of its own.
- Mechanical Identification
identification of mechanical systems in commercial, institutional, and industrial work — pipe markers for HVAC hot/chilled/condenser water, steam, condensate, refrigerant, natural gas, fuel oil, glycol, compressed air, and process fluids; ductwork labels for supply, return, exhaust, and outside air; valve tags with numbered schedules; equipment nameplates for mechanical rooms and field-mounted equipment; flow-direction arrows; and color-coded content banding, on new construction, renovation, and fit-out.
- Vibration Isolation and Seismic Restraint
Vibration isolation and seismic restraint of mechanical, electrical, and plumbing (MEP) equipment, piping, ductwork, and conduit in commercial, institutional, healthcare, and industrial buildings. Covers isolator selection by required static deflection against equipment disturbing frequency; neoprene and rubber-in-shear mounts and pads, open and restrained spring isolators, spring and combination hangers, and air springs; inertia and structural-steel bases; flexible pipe connectors, flexible conduit, and thrust restraints; and the restraint of nonstructural components and their attachments per ASCE/SEI 7 Chapter 13 and the IBC — including cable and rigid bracing of distribution systems, equipment snubbers, restrained (seismic) spring isolators, anchorage to housekeeping pads and structure, special seismic certification of active equipment, and special inspection.
Plumbing
- Backflow Prevention
The assemblies and devices that keep water from flowing backward into a potable supply, in commercial, institutional, industrial, and multifamily buildings served by a utility or by a private source. Covers the building water service assembly at the point of entry, the premises isolation assembly on it, the isolation assemblies at internal cross-connections such as equipment makeup water, chemical feed, laboratory, and irrigation connections, and the detector and non-detector assemblies on a fire service supplied from a potable main. Establishes how the degree of hazard at each connection is classified, which assembly type that classification admits, the construction, listing, and lead-free certification of each assembly, its orientation, height, clearances, support, relief discharge, outdoor enclosure or vault, and the initial field test and certification by a certified tester that puts it in service.
- Commercial Water Heaters
Equipment that generates and stores domestic hot water for commercial, institutional, and industrial buildings — fuel-fired and electric storage water heaters, instantaneous and semi-instantaneous water heaters, heat pump water heaters, and indirect-fired storage vessels heated by a boiler plant, a solar loop, or recovered heat. Covers the storage vessel and its corrosion protection, the combustion air and vent system, the fuel gas and electrical connections at the equipment, condensate handling, thermal expansion control, temperature and pressure relief, the master mixing valve, the recirculation pump and its controls and balancing, equipment anchorage, startup, and field performance testing.
- Common Work Results for Plumbing
Establishing the shared materials, joining methods, workmanship, hangers and supports, pipe sleeves and sleeve seals, escutcheons, meters and gages, general-duty valves, dielectric isolation, vibration and seismic controls, pressure testing, and disinfection baseline that applies uniformly across all plumbing piping systems in a building - domestic water, sanitary, vent, storm, and gas - for commercial, institutional, industrial, multi-family, and renovation projects. This is the plumbing common-results umbrella section every system-specific plumbing standard references so common requirements are stated once.
- Compressed Air Systems
Facility compressed air systems that generate, condition, store, and distribute general-service air at facility pressures for pneumatic tools, actuators, blow-off and cleaning stations, laboratory apparatus, instrument and pneumatic control loops, pulse-jet filter cleaning, and the supervisory air supply of sprinkler systems where one plant serves more than the sprinklers. Covers the decisions that define such a system: the ISO 8573-1 air quality class for each contaminant, compressor type, lubrication, cooling, capacity control and redundancy, aftercooling and separation, dryer type and arrangement, filtration, receivers, condensate drains and oil-water separation, distribution piping material, joining, sizing and configuration, drops and outlets, controls and monitoring, pressure and leak testing, purity verification, startup, warranty, and spares, in new construction and in expansion of an existing system.
- Disinfection of Domestic Water Systems
Chlorination, flushing, and bacteriological clearance testing of newly constructed, extended, repaired, or temporarily opened domestic potable water piping and inline appurtenances — building service mains, cold- and hot-water distribution piping, on-premise storage tanks, and any piping filled with potable water for the first time — on commercial, institutional, healthcare, and multi-family projects where the plumbing code requires bacteriological clearance before the system is placed in service. Covers selection of disinfecting agent and method, contact-time and concentration combinations, the flushing protocol and dechlorination of flush water, field chlorine-residual testing, and collection and laboratory analysis of bacteriological samples.
- Domestic Water Booster Pump Systems
Packaged domestic (potable) water pressure-booster pump systems that raise municipal or building supply pressure to serve upper floors, high-demand fixtures, and flushometer groups in commercial, institutional, multistory residential, and industrial buildings. Covers variable-speed (VFD) multiplex packaged systems built on vertical multistage centrifugal pumps; duplex and triplex lead/lag/standby staging and N+1 redundancy; constant-discharge-pressure and proportional (zone) control; flow and boosted-pressure sizing from the system curve and the available suction pressure; the hydropneumatic (bladder) tank that prevents short-cycling and supports no-flow shutdown; low-suction-pressure cutoff and pressure-sustaining protection of the city main; lead-free wetted materials under the federal Reduce Lead in Drinking Water Act and NSF/ANSI/CAN 61 and 372; the skid, manifolds, valves, controls, and BAS interface; disinfection and testing.
- Domestic Water Heating and Storage Equipment
specifying domestic hot water storage and distribution accessory equipment on commercial, institutional, and multi-family residential plumbing systems - unfired storage tanks (glass-lined, stone-lined, stainless, copper-lined), thermostatic mixing valves (system and point-of-use), hot-water recirculation pumps and controls, potable thermal expansion tanks, indirect-heating heat exchangers (brazed-plate, shell-and-tube), heat-pump storage configurations, and integral accessories (aquastats, temperature-pressure relief valves, drain valves) on new construction and major renovation with engineered plumbing documents.
- Domestic Water Piping
Potable cold water, hot water, and hot water return piping inside a building — the pipe and tube, the fittings and joints, the valves and water hammer arrestors installed in the line, and the supports, expansion provisions, insulation, freeze protection, identification, pressure testing, flushing, and disinfection that go with them. The scope runs from the discharge of the building water service assembly to the stop, union, or rough-in connection at each fixture and each item of equipment, in commercial, institutional, industrial, and multifamily buildings served by a utility supply or by a private on-site source.
- Domestic Water Piping Specialties and Valves
assembled accessories and inline specialties on the domestic cold water, hot water, and hot water recirculation distribution systems of commercial, institutional, and industrial buildings — pressure-reducing valve (PRV) stations, domestic hot water expansion tanks, dielectric isolation fittings at dissimilar-metal connections, inline strainers, pipe identification and valve tags, pipe sleeves, escutcheons, firestop collars at penetrations, and equipment isolation/drain valve packages at water heaters, booster pumps, and treatment equipment. Covers new construction and renovation served by a municipal supply or on-site pressure source.
- Domestic Water Softeners and Filtration
Point-of-entry treatment equipment that conditions the potable water supply to a building before it enters the distribution piping, in commercial, institutional, industrial, and multifamily buildings served by a utility supply or by a private well. Covers cation-exchange water softeners and the scale-conditioning alternatives to them, sediment filtration, activated carbon filtration, iron and manganese removal, point-of-entry reverse osmosis, point-of-entry ultraviolet disinfection, chemical feed into the potable supply, the bypass, isolation, sampling, and indirect-waste connections at that equipment, its controls and monitoring, and its startup, protection during system disinfection, and field testing.
- General-Duty Valves for Plumbing Piping
general-duty isolation, check, and balancing valves in domestic potable cold water, domestic hot water, and hot water recirculation piping in commercial, institutional, and industrial buildings; gate, ball, globe, butterfly, swing check, silent check, wafer check, and manual or automatic balancing valves NPS 1/4 through NPS 12 from the water service entrance to fixture shutoffs and equipment connections, rated to 250 psi CWP and 250°F, with mandatory NSF 61/372 lead-free certification.
- Grease Interceptors
Grease interceptors that pretreat the fats, oils, and grease carried by the drainage from commercial kitchens, cafeterias, commissaries, bakeries, and other food-service operations before that drainage reaches the sanitary building drain: hydromechanical grease interceptors rated under PDI G101 and ASME A112.14.3, automatic grease removal devices under ASME A112.14.4, and gravity grease interceptors of precast concrete, cast-in-place concrete, fiberglass, or polyethylene. Covers the interceptor types furnished, the sizing method and the inputs it needs, the flow control fitting and air intake, body and tank materials, structural loading and anti-flotation of buried tanks, inlet and outlet fittings, access risers and covers, venting, the effluent sampling point, which fixtures and appliances connect to the interceptor, the grease waste pipe material and slope between those fixtures and the interceptor, setting and testing, and the pump-out program the Owner carries after acceptance.
- Medical Gas and Vacuum Systems
Piped medical gas and vacuum systems serving patient care areas in healthcare facilities, including oxygen, medical air, medical-surgical vacuum, waste anesthetic gas disposal (WAGD), nitrous oxide, nitrogen, and instrument air; source equipment (bulk oxygen, cylinder manifolds, compressors, vacuum pumps), distribution piping, zone valves, alarm panels, and station outlets governed by NFPA 99.
- Natural Gas Piping
Field-installed fuel-gas piping conveying natural gas or undiluted liquefied petroleum (LP) gas from the utility meter or LP-gas second-stage regulator to gas-fired appliances and equipment, including interior distribution piping, exterior aboveground piping, and buried exterior service piping within the property line. Covers system pressure tiers (low-pressure systems at or below ½ psig and elevated-pressure systems at 2 psig and 5 psig with line-pressure regulators), pipe and tubing materials by service and location (Schedule 40 steel, polyethylene for underground use, corrugated stainless steel tubing, and copper where the gas sulfur content permits), threaded and welded joints, gas valves, line-pressure regulators with overpressure protection, sediment traps and appliance connections, corrosion protection of buried steel, electrical bonding of metallic piping and CSST, and the complete pressure-test and purging sequence required by NFPA 54.
- Packaged Pump and Lift Stations
Factory-assembled pump and lift stations on the site that lift raw sanitary sewage, screened or settled effluent, or stormwater to a site sewer, a force main, or an outfall where gravity flow is not available, on commercial, institutional, industrial, campus, and multi-family sites. Covers the wet well basin and its anti-flotation and traffic provisions, the pumps and motors in wet well submersible, wet well and dry well, and above-grade suction-lift arrangements, the guide rail removal system, the station discharge piping, check and isolation valves and the valve vault, level control and its backup devices, the control panel with its alternation, protection, alarm, and telemetry provisions, wet well ventilation and odor control, the standby power interface at the station, factory and field testing, installation of the package in the prepared excavation, warranty, and spare parts, from the influent connection at the basin wall to the discharge connection at the station limit.
- Plumbing Fixtures
Plumbing fixtures and their trim, carriers, supply stops, and exposed waste connections in commercial, institutional, and industrial buildings. Covers water closets, urinals, lavatories, service sinks and mop basins, hand-wash sinks, break room and office kitchen sinks, showers, drinking fountains and bottle fillers, and plumbed emergency eyewash and drench shower equipment. Establishes the fixture material and construction, the flush and flow technology, the consumption rates measured against the federal EPAct maximums and the EPA WaterSense specifications, the mounting and carrier requirements, the accessibility criteria, the scald-protection arrangement at the fixture, and the acceptance testing that proves each fixture performs at its rated volume or flow.
- Plumbing Insulation
Thermal insulation, jacketing, vapor retarders, and ADA protective covers for plumbing piping inside buildings — domestic hot water and recirculation (energy conservation), domestic cold water (condensation control), and storm and roof-drainage bodies and overflow piping (condensation on cold rainwater). Covers material selection by service (mineral/glass fiber with all-service jacket for hot lines, closed-cell elastomeric for cold and condensation control, phenolic where space is limited), insulation thickness by the adopted energy code, continuous vapor-retarder construction on cold and storm piping, jacketing by exposure (all-service jacket concealed, PVC fitting covers, metal jacket in mechanical rooms and outdoors), insulation inserts and shields at hangers, and molded protective covers on the hot, cold, and waste/trap piping below accessible lavatories and sinks.
- Plumbing Piping Identification
identifying and labeling aboveground, exposed, and accessible plumbing piping in commercial, institutional, and industrial buildings - domestic cold water, domestic hot water and recirculation, sanitary waste and vent, storm drainage, non-potable reuse, reclaimed/recycled (purple) water, and interior building natural gas distribution. Covers label legend content, background/text color schemes, letter and marker sizing by pipe outside diameter, flow-direction arrows, placement frequency and location, and the valve-tag/valve-schedule deliverable. Applies to new construction and renovation across all project types where code-required pipe identification is mandated.
- Plumbing Pumps
Standalone, in-line, or close-coupled centrifugal pumps in domestic plumbing service where a single circulator or transfer pump is the primary product of work — hot water recirculation pumps (wet-rotor in-line circulators, dedicated return pumps, and demand-controlled pump/sensor pairs), small cold-water transfer and booster-duty inline pumps, clean-condensate transfer pumps, and HVAC condensate removal pumps serving plumbing systems — in commercial, institutional, multifamily residential, and light industrial buildings. Covers pump type and capacity selection, motor and impeller construction, lead-free and NSF/ANSI/CAN 61 and 372 compliance, recirculation controls (time-clock, aquastat, and demand-signal), connection orientation, isolation and check valves, vibration isolation, and functional testing.
- Plumbing Specialties
Drainage and water-distribution specialties that serve the plumbing system without being fixtures themselves — cleanouts, floor and area drains, trap seal protection (trap primers and barrier-type trap seal devices), hose bibbs and freezeless wall hydrants, water hammer arrestors, backwater valves, and thermostatic mixing valves (master and point-of-use). Covers materials and finishes, load and duty ratings, freeze protection, scald protection, access and identification, installation, and testing for these items in commercial, institutional, and industrial buildings.
- Roof Drainage
Roof drainage on and within the building for commercial, institutional, industrial, and multi-family projects: primary roof drains with their domes, clamping rings, underdeck clamps, extensions, and deck accessories; deck, balcony, and planter drains that discharge to the building storm system; the secondary drainage system provided by overflow roof drains or overflow scuppers; controlled-flow and siphonic primary drainage; vertical leaders and horizontal storm piping inside the building; expansion provisions, hangers, cleanout locations, identification, and testing; and the building storm drain out to five feet beyond the foundation wall.
- Sanitary Drainage Specialties
discrete sanitary drainage assemblies that connect the waste-and-vent system to occupied and service spaces — floor drains, area drains, cleanouts, fixture carriers for wall-hung water closets and urinals, trap primers and trap-seal protection devices, backwater (check) valves, drum and hub traps, and drain accessories (sediment buckets, grates, strainers, extension necks, clamping collars). Applies to commercial, healthcare, education, industrial, food-service, and residential buildings wherever the sanitary drainage system terminates at a usable drainage point other than a fixture proper.
- Sanitary Waste and Vent Piping
The sanitary drain, waste, and vent piping inside a building and the building drain out to five feet beyond the foundation wall, in commercial, institutional, industrial, and multifamily buildings: the pipe, fittings, joints, and couplings in cast iron, PVC, ABS, copper, galvanized steel, stainless steel, and polyethylene; the fixture traps, trap arms, and the venting that protects them; the slope and the changes of direction of horizontal drainage; the indirect waste receptors that take equipment discharge; the connections to fixtures, floor drains, cleanouts, grease interceptors, sumps, and ejectors; hangers, vertical support, seismic restraint, thermal movement, acoustic treatment, sleeves, and firestopping; below-slab bedding and backfill; and the rough-in and final tests that prove the system tight.
- Sump and Sewage Pumps
Packaged sump pumps, sewage ejector pumps, and grinder pumps with their basins, covers, controls, and alarms, installed inside or immediately adjacent to commercial, institutional, and industrial buildings to lift below-grade and gravity-deficient drainage into the building gravity drainage system. Covers clear-water and storm sump pumps, solids-handling sewage ejector pumps, grinder pumps, and effluent pumps; simplex and duplex configurations; submersible and pedestal pumps; fiberglass, polyethylene, and concrete basins; gas-tight covers and basin venting for sewage service; guide-rail removal systems; float, sealed mechanical, and transducer level controls; check and isolation valves on each pump; and high-water alarms with audible/visual signals and building automation dry contacts.
- Trench Drains and Floor Drains
selecting and specifying trench drains (linear channel drains with grates) and floor drains (point drains with strainers) for non-residential interior and immediately adjacent exterior floors — commercial kitchens and food-processing, parking structures and wash bays, mechanical and electrical rooms, loading docks, industrial and process floors, and locker/shower rooms. Covers channel bodies, grates, frames, outlets, traps, trap primers, sediment buckets, and integral waterproofing flanges as assembled systems, including load class, hydraulic sizing, ADA grate compliance, and fluid compatibility.
- Water Hammer Arresters and Shock Control
Selecting and installing listed water hammer arresters in commercial, institutional, and multi-family residential plumbing wherever quick-closing valves create hydraulic shock - solenoid appliance valves (dishwashers, washing machines, ice makers), irrigation zone valves, flush valves, and any automatic or lever-handle valve capable of rapid closure. Covers PDI size-class selection (A through F), pressure and temperature rating, mechanism and material choice, connection type, and placement, per PDI-WH 201 and ASSE 1010-2021, for new construction and renovation.
Fire Protection
- Clean Agent Fire Suppression Systems
Engineered and pre-engineered gaseous total-flooding clean-agent fire extinguishing systems that protect high-value, mission-critical, or water-sensitive enclosures by discharging an electrically non-conductive, residue-free agent that suppresses fire without wetting or contaminating the protected contents. Covers both families of agent recognized by NFPA 2001 — halocarbon agents (such as HFC-227ea and the fluoroketone FK-5-1-12), which extinguish primarily by heat absorption, and inert-gas agents (such as IG-541, IG-55, and IG-100), which extinguish by reducing the oxygen concentration below that needed to support combustion. Addresses agent selection, design concentration and the NOAEL/LOAEL occupant-safety margins, cross-zoned detection and the releasing control unit, manual release and abort, agent storage containers and distribution piping and nozzles, discharge time and minimum hold (soak) time, enclosure integrity verified by a door-fan (enclosure-integrity) test, pressure-relief venting of the enclosure, and acceptance testing and commissioning. Typical protected spaces include data centers and server rooms, telecommunications and equipment rooms, control rooms, electrical and switchgear rooms, and museum, library, and archival storage.
- Commercial Kitchen Hood Fire Suppression
Pre-engineered, wet-chemical, fixed-nozzle fire-extinguishing systems that protect commercial cooking operations — the cooking appliances, the hood plenum, and the exhaust duct — in restaurants, institutional and commercial kitchens, cafeterias, and similar food-service occupancies. Covers the potassium-based wet-chemical agent and its storage cylinder, the cartridge (nitrogen) actuation and regulated-release mechanism, the appliance-specific nozzle and distribution-piping network sized by flow points, automatic detection by fusible links or thermal detectors and manual pull-station actuation, the fuel and power shutoff interlock (gas valve and electric-appliance shutoff) and exhaust-fan operation on discharge, the interface to the building fire alarm system, and the listing, acceptance testing, and semiannual inspection and maintenance program (including fusible-link replacement). The system shall be listed to UL 300 and shall comply with NFPA 96 and NFPA 17A. Applicable to systems protecting fryers, ranges, griddles, broilers, char-broilers, woks, tilt skillets, and similar grease-producing appliances under a Type I (grease) hood.
- Common Work Results for Fire Suppression
project-wide administrative and execution provisions that apply uniformly to all fire suppression work on commercial, institutional, industrial, multi-family, and high-rise projects — contractor qualification, submittals, trade coordination, workmanship, identification and labeling, the project seismic design basis, flushing and cleaning, hydrostatic and functional acceptance testing, record documents, and owner training. This is the umbrella standard that consolidates provisions otherwise duplicated across wet-pipe, dry-pipe, pre-action/deluge, standpipe, fire pump, clean-agent, and kitchen-hood sections.
- Dry-Pipe Fire Sprinkler Systems
Automatic dry-pipe sprinkler systems designed to NFPA 13, in which the piping downstream of a dry-pipe valve is held under supervisory air or nitrogen because the piping is exposed to freezing. Covers the decisions that exist only on a dry system: the dry-pipe valve and its trim, the quick-opening device, the supervisory gas source and its pressures, water delivery time, pitch and low-point drainage, the corrosion consequences of a wet-and-dry pipe interior, the provisions for piping in refrigerated spaces, and the trip test and 24-hour air leakage test that prove the installation.
- Fire Alarm Systems
Protected premises fire alarm and signaling systems for commercial, institutional, industrial, mercantile, assembly, healthcare, educational, and multi-family residential buildings. Covers the fire alarm control unit, annunciation, addressable and conventional architectures, automatic and manual initiating devices, waterflow and supervisory signal devices, audible and visible notification appliances, in-building emergency voice/alarm communications, circuit class and pathway survivability, primary and secondary power, off-premises signal transmission to a supervising station, fire alarm wiring, emergency control function interfaces, and acceptance testing.
- Fire Department Connections
Specifying, procuring, and installing the assemblies that let fire department pumper apparatus supplement the water supply to automatic sprinkler, standpipe, and combination systems - wall-mounted exposed, recessed, freestanding, and sidewalk FDCs including the body, inlets, swing clappers, integral check valve, automatic ball drip, pipe connection, caps, and signage. Applies to new construction and to additions or retrofits where a new or relocated FDC is required by code or AHJ.
- Fire Hydrants
Fire hydrants on private fire service mains and public/private water distribution systems serving developed commercial, institutional, industrial, multifamily, and campus sites. Covers dry-barrel hydrants for freeze climates and wet-barrel hydrants for mild/non-freezing climates, traffic (breakaway) and non-traffic types, standard-nozzle and Storz configurations, flush-type hydrants, and ancillary components (auxiliary isolation valves, breakaway flanges, drain valves, extensions). Applies at new construction and at hydrant replacement or relocation.
- Fire Protection Piping and Specialties
The common aboveground and underground piping, fittings, joints, control and check valves, alarm and supervisory devices, fire department connections, drains, gauges, hangers, and seismic bracing that serve all water-based fire suppression systems in commercial, institutional, industrial, high-rise, and multi-family construction. This is the foundational piping backbone that wet-pipe, dry-pipe, pre-action, and standpipe system standards draw from for their supply piping. Covers black and galvanized steel, copper, listed CPVC, and underground ductile iron; threaded, grooved, welded, and flanged joining; OS&Y gate, butterfly, ball, and check valves; alarm and dry-pipe valve trim; waterflow, tamper, and pressure switches; fire department connections; test-and-drain and main-drain assemblies; pressure gauges and pressure-regulating valves.
- Fire Pump Controllers
Selecting and specifying listed fire pump controllers for electric-motor-driven and diesel-engine-driven centrifugal fire pumps in commercial, industrial, institutional, and high-rise fire suppression systems. Covers across-the-line, reduced-inrush (wye-delta, part-winding, solid-state), and variable-speed (VFD) electric controllers; diesel engine controllers; limited-service controllers; medium-voltage controllers; and combination controller/power-transfer-switch units for wet-pipe, dry-pipe, deluge, and standpipe systems.
- Fire Pumps
Stationary fire pump assemblies installed under NFPA 20 to supply automatic sprinkler systems, standpipe systems, combined sprinkler and standpipe risers, water spray systems, private hydrant mains, and the water side of foam-water and foam systems, wherever the available supply cannot deliver the system demand at the required pressure. Covers the listed centrifugal fire pump in its horizontal split-case, end-suction, vertical in-line, multistage multiport, and vertical turbine forms; the listed electric motor or diesel engine driver, with the engine's cooling, exhaust, fuel supply at the engine, starting batteries, and battery chargers; the jockey pump and its own controller; the suction and discharge piping and trim inside the pump room, including the listed control and check valves, the relief valves, the hose valve test header or flow meter loop, the gauges, and the automatic air release on the casing; the NEC Article 695 power source arrangement stated as a design requirement; the supervisory signals the assembly sends to the fire alarm system; the fire pump room provisions of NFPA 20 Chapter 4; the certified factory curve; the field acceptance test of NFPA 20 Chapter 14; warranty; and spare parts.
- Foam Fire Suppression Systems
Fixed and semi-fixed foam fire suppression systems protecting flammable and combustible liquid hazards in commercial and industrial construction - low-, medium-, and high-expansion foam systems, foam-water sprinkler and spray systems, foam concentrate proportioning and storage, and discharge devices for aircraft hangars, petroleum tank farms, fuel loading racks, transformer vaults, chemical storage warehouses, and process areas handling combustible liquids.
- Mass Notification Systems
Emergency communications systems under NFPA 72 Chapter 24 that warn the occupants of a building, the population of a site or campus, or a defined list of recipients of a fire or non-fire emergency and tell them what to do. Covers the risk analysis that establishes the system's scope as a design deliverable; in-building mass notification with its autonomous control unit, local operating consoles, priority of emergency messages over fire alarm evacuation signaling, visible notification and textual signs for non-fire events, and voice intelligibility as a measured acceptance criterion; wide-area mass notification using high-power speaker arrays; distributed-recipient mass notification by text, email, telephone, mobile application, and desktop alert as an integration requirement; two-way emergency call stations that are part of a mass notification function; pathway class and survivability; primary and secondary power; the message library and the live and prerecorded message hierarchy; and acceptance testing with intelligibility verification. Applies to campuses, healthcare, high-rise and assembly occupancies, transportation terminals, industrial sites, and Department of Defense facilities subject to UFC 4-021-01.
- Portable Fire Extinguishers and Cabinets
Portable (hand-carried and wheeled) fire extinguishers and their mounting hardware, brackets, and cabinets installed throughout commercial, institutional, industrial, mercantile, assembly, and residential buildings to provide a first line of manual fire suppression by occupants and staff. Covers extinguisher selection by fire class (A, B, C, D, K) and occupancy hazard level, UL fire rating and agent type, distribution and travel-distance layout, mounting heights and brackets, recessed/semi-recessed/surface-mounted and fire-rated cabinets, identification and signage, installation, and the inspection/maintenance/hydrostatic-test program required to keep the units in service.
- Pre-Action and Deluge Sprinkler Systems
Automatic sprinkler systems designed to NFPA 13 in which the piping downstream of a pre-action or deluge valve is normally dry and water is admitted by a releasing control unit acting on a fire detection signal rather than by the opening of a sprinkler alone. Covers the decisions that exist only on these systems: the system type (non-interlock, single-interlock, and double-interlock pre-action, and deluge), the releasing detection and its initiating logic, the releasing control unit and its listing for releasing service, the release actuation of the valve, manual release and any release delay, the auxiliary functions tied to a release, the pre-action or deluge valve and its trim, the supervisory gas and its supply on a pre-action system, the water delivery time of a double-interlock system, the open discharge devices and zoning of a deluge system, and the trip test, releasing sequence tests, and air leakage test that prove the installation.
- Public Safety Radio Enhancement Systems
Design, specification, installation, testing, and acceptance of Emergency Responder Communication Enhancement Systems (ERCES/ERRCS, also called Public Safety BDA/DAS) in new and existing buildings where code-required first-responder radio coverage cannot be achieved passively. Applies to commercial, institutional, high-rise, underground, parking-structure, and assembly occupancies subject to IFC Section 510, NFPA 1225, or local fire-code equivalents. Covers the full active assembly: donor antenna, head-end bidirectional amplifier (BDA), coaxial and fiber distribution, remote power units, service antennas, battery backup, FACP supervisory interface, and FCC licensing coordination.
- Standpipe Systems
Standpipe and hose systems installed in buildings to provide a fixed water supply for manual fire-fighting operations by fire department personnel and, where the system class provides for it, by occupants. Covers Class I, Class II, and Class III systems of the automatic-wet, automatic-dry, semi-automatic-dry, manual-wet, and manual-dry types, on dedicated risers and on combined sprinkler/standpipe risers. Addresses system classification, pressure limits and zoning, the demand at the hydraulically most remote hose connection, hose connection locations and mounting, hose valves and threads, pressure-regulating devices and their test drain riser, occupant-use hose stations, identification signage, the standpipe required during construction, and the flushing, hydrostatic, flow, and device acceptance tests that put the system into service.
- Underground Fire Service Mains
Private underground fire service mains and appurtenances per NFPA 24 supplying building sprinkler systems, private hydrants, and fire department connections. Covers the buried piping from the point of connection at the public water main or other approved supply, through the lead-in to the building, including pipe material and pressure class, joints and thrust restraint, buried and exterior control valves (post indicator valves and supervised gate valves), private hydrants, the underground portion serving fire department connections, depth of cover and separation from other utilities, thrust blocks and restrained-joint design, flushing, hydrostatic testing, and acceptance per the NFPA Contractor's Material and Test Certificate for underground piping.
- Wet-Pipe Fire Sprinkler Systems
Automatic wet-pipe fire sprinkler systems designed under NFPA 13 for commercial, institutional, industrial, high-rise, and multi-family residential buildings, together with the requirements common to every automatic sprinkler system that the dry-pipe and pre-action layers build on. Covers occupancy hazard classification, the design approach, design density and area, hose stream allowance and water supply duration, the water supply basis, pipe arrangement, the hanging and seismic bracing policy for sprinkler piping, sprinkler selection (type, thermal response, temperature rating, K-factor, finish, and corrosion resistance), flexible sprinkler connections, the wet-pipe riser, floor and zone control assemblies, alarm and supervisory provisions, freeze-exposed pockets on a wet system, acceptance testing, warranty, and the spare sprinkler cabinet.
Building Envelope
- Air Barriers
Continuous air barrier systems for the above-grade exterior wall enclosure of commercial, institutional, and multifamily buildings, where the objective is to control unintended air movement across the enclosure. Covers the primary air barrier material on the wall field (fluid-applied membranes, self-adhered sheet membranes, mechanically-fastened sheets, integrated and board sheathing with sealed joints, and closed-cell spray polyurethane foam used as an air barrier), the accessories and transition materials that carry the air barrier plane across changes of material and plane, the tie-ins to the roof, below-grade waterproofing, and fenestration, substrate preparation and priming, the exposure window before cover-up, and the field verification that proves the installed plane is continuous — field adhesion testing, air leakage site detection, and whole-building air leakage testing.
- Asphalt Shingle Roofing
Steep-slope (2:12 and greater) asphalt shingle roofing on new construction and full reroof replacements for low-rise commercial, institutional, and residential-scale buildings. Covers fiberglass-mat asphalt shingles (three-tab, architectural/laminated, and premium/designer profiles) and their integral system components: underlayment, ice-and-water shield, starter strips, hip and ridge cap, and shingle fastening, together with fire, wind, impact, and algae-resistance selection.
- Below-Grade Waterproofing
Waterproofing of below-grade walls and slabs that retain earth and enclose interior space, where a groundwater investigation confirms a hydrostatic pressure condition or where the Owner requires waterproofing-level protection regardless of the groundwater finding. Covers the membrane families used below grade (self-adhering modified bituminous sheet, cold fluid-applied elastomeric, hot-applied rubberized asphalt, sodium bentonite geotextile composite, pre-applied bonded sheet, and surface-applied cementitious crystalline coating), positive-side, negative-side, and pre-applied blindside application, substrate preparation and priming, application temperature limits, laps and terminations, detailing at penetrations and joints, the protection course, the drainage layer bearing on the membrane, field watertightness verification, backfill against waterproofed surfaces, and warranties.
- Building Expansion Joints
Cover assemblies, preformed fillers, and fire-barrier systems for building expansion and seismic separation joints in new construction and renovation of commercial, institutional, and industrial buildings - floor, wall, ceiling, roof, and transition assemblies that accommodate thermal, wind, seismic, and settlement movement across a structural separation whose location and width were set by the structural engineer.
- Building Thermal Insulation
Thermal insulation installed in the opaque building envelope of commercial, institutional, multifamily, and residential buildings, covering above-grade wall cavity and continuous insulation, low-slope and steep-slope roof and attic insulation, floors and ceilings over unconditioned space, crawl space enclosures, below-grade foundation walls, and under-slab and slab-edge insulation. Covers all principal insulation forms sold in the North American market: mineral fiber batt, blanket, and board; loose-fill and dense-packed cellulose, fiberglass, and mineral wool; extruded, expanded, and graphite-enhanced polystyrene board; polyisocyanurate board; cellular glass; wood fiber and cellulosic board; spray-applied polyurethane foam; and reflective insulation and radiant barriers. Also covers the thermal resistance basis used to demonstrate energy code compliance, surface burning and foam plastic fire requirements, vapor retarder classification and placement, air barrier coordination, thermal bridge mitigation, and field verification before assemblies are concealed.
- Common Work Results for Thermal and Moisture Protection
Specify the cross-cutting, project-wide requirements that apply uniformly to all building-envelope (thermal and moisture protection) work on commercial, institutional, multifamily, and mixed-use projects governed by the IBC, IECC, and ASHRAE 90.1. This umbrella section declares the governing code basis and climate zone, sets common storage, handling, and environmental-condition limits, owns the air-and-water control-plane continuity and trade-coordination responsibility, and establishes the shared mock-up, installer-qualification, field-testing (blower-door, thermography, ASTM E1105 spray), and warranty baselines that every downstream envelope section inherits rather than restates.
- Dampproofing
moisture-resistant coatings and treatments on below-grade concrete and masonry foundation walls, retaining walls enclosing interior space, and slabs-on-grade where a groundwater investigation confirms no hydrostatic pressure (IRC R406; IBC Section 1805.2). Covers bituminous (hot-applied asphalt, cold-applied emulsion, fibrous asphalt), cementitious (acrylic-modified cement, surface-bonding mortar), and under-slab polyethylene dampproofing, plus masonry parging, form-tie patching, protection board, and extent of application from top of footing to finished grade.
- Exterior Insulation and Finish Systems (EIFS)
Class PB exterior insulation and finish systems installed as the above-grade exterior wall cladding of commercial, institutional, and multifamily buildings. Covers the full layered assembly and both water management classes the building code recognizes: EIFS with drainage, in which a water-resistive barrier on the sheathing and a drained cavity behind the insulation manage incidental water, and barrier EIFS, in which the insulation is adhered directly to the substrate and the finish face carries the water management. Addresses the sheathing substrate the system is applied over, the water-resistive barrier and its relationship to the wall air barrier, the drainage means and drainage efficiency, the expanded polystyrene insulation board and its adhesive or mechanical attachment, the reinforced base coat and the reinforcing mesh impact classes, the finish coat with its type, texture, color, and light reflectance limits, aesthetic reveals, expansion joints, back-wrapping and terminations, the interfaces to flashing and joint sealants, wind load and thermal performance, the surface burning and exterior wall flame propagation requirements that govern a combustible foam plastic cladding, and the mockup, inspection, water testing, and moisture survey that verify the installed wall.
- Exterior Weather Sealants
Selecting, specifying, and installing cold-applied elastomeric sealants that weatherproof perimeter, transition, and penetration joints in exterior building assemblies, on new construction and on restoration/recaulking of commercial and institutional buildings. Covers window and curtain wall perimeter joints, door frame perimeters, above-grade control and expansion joints in concrete, masonry, metal panel, EIFS, and wood-framed walls, through-wall penetrations, thresholds, and horizontal ledge joints, using single- and multicomponent silicone, polyurethane, and polyurethane-hybrid systems with backer rods, bond-breaker tape, and primers.
- Fluid-Applied Roofing and Coatings
Liquid-applied roof coatings and membranes that cure in place to a seamless monolithic film on low-slope and low-pitch roofs — acrylic, silicone, polyurethane, and spray-polyurethane-foam (SPF) topcoat systems. Covers new-construction membranes over deck or insulation, restoration re-coating of weathered but sound built-up, modified-bitumen, single-ply, metal-panel, and concrete roofs without tear-off, reflective cool-roof upgrades, and maintenance re-coat cycles, including substrate prep, primer, fabric reinforcement, dry-film thickness, reflectance/emittance compliance, and 5/10/15/20-year NDL warranty tiers.
- Fluid-Applied Waterproofing
Seamless membranes built up in place from a liquid on concrete and masonry surfaces that enclose or protect occupied space: plaza and amenity decks, planters and landscaped areas, split-slab and topping-slab assemblies, between-slab and under-topping interior conditions, parking structure intermediate and roof levels with an exposed traffic-bearing membrane, and below-grade walls where a monolithic bonded membrane is selected instead of sheet. Covers hot fluid-applied rubberized asphalt and the cold liquid-applied chemistries (polyurethane, polymethyl methacrylate, polyurea, and polymer-modified asphalt emulsion), in both the buried configuration under a separate wearing course and the exposed configuration with an integral wearing surface, together with substrate preparation, primer, reinforcement, thickness control, protection course, drainage composite, root barrier, terminations, drains and penetrations, integrity testing, and warranty.
- Foundation Drainage
Perimeter and sub-slab drainage protecting below-grade structures on commercial, institutional, and residential projects. Covers the design groundwater basis, perforated thermoplastic perimeter drain pipe, open-graded aggregate envelopes, geotextile filtration, prefabricated wall drainage composites, sub-slab drainage layers and collector piping, crawl space drainage, cleanouts, sump pits with pumps and alarms, gravity and pumped discharge, sequencing with below-grade waterproofing, and field verification before concealment.
- Gutters and Downspouts
Exterior rainwater conveyance hung at or immediately below the building eave - eave-hung gutters (K-style, half-round, box/built-in), leader heads, downspouts, elbows, offsets, outlet tubes, strainers, splash blocks, and grade or storm-connection terminations. Covers sloped-roof commercial, institutional, industrial, multifamily, and residential-scale commercial buildings, and flat-roof perimeter edge drainage where gutters replace internal drains; in prefinished aluminum, galvanized steel, Galvalume, copper, and zinc; seamless field-formed or shop-fabricated sections.
- Joint Sealants
Field-applied, cold liquid-applied elastomeric and latex joint sealants used to weatherseal and close working and non-working joints in the building envelope and interior. Covers exterior vertical weatherseal joints between dissimilar wall materials, expansion and control joints in concrete and masonry, perimeter joints around windows, doors, louvers, and other openings, interior acoustical and concealed joints, and horizontal traffic-bearing joints in walkways and decks. Addresses sealant chemistry selection (neutral- and acid-cure silicone, single- and multi-component polyurethane, silyl-terminated polyether/polymer hybrid, and acrylic latex), movement capability classes established by ASTM C719 cyclic-movement testing, ASTM C920 Type/Grade/Class/Use classification, joint design and width-to-depth ratio, backer rod and bond-breaker selection, primers, non-staining sealant on porous stone, sealant-substrate compatibility and adhesion testing, field adhesion testing, and weatherproofing warranties.
- Membrane Roofing
Roof systems in which a flexible sheet membrane forms the primary weather barrier, together with the insulation, cover board, vapor retarder, attachment, flashings, and terminations that make the membrane work. Covers thermoplastic sheet (TPO, PVC, KEE), thermoset sheet (EPDM), and polymer-modified bitumen sheet (SBS, APP) membranes; mechanically attached, induction-welded, adhered, self-adhered, torch-applied, hot-mopped, cold-adhesive, and ballasted attachment; new construction, tear-off replacement, recover, and partial replacement; wind uplift and fire design basis, field seaming, flashing and termination detailing, field testing, and warranty.
- Metal Roof Panels
Formed metal roof panel systems that form the watershedding roof plane of commercial, institutional, industrial, agricultural, multifamily, and residential buildings: mechanically seamed and snap-lock standing-seam panels, batten-seam panels, and through-fastened lapped panels, in coated steel, aluminum, copper, and zinc, installed either as structural panels spanning open purlins and framing or as architectural panels over a continuous solid deck. Covers the wind uplift, water penetration, air leakage, and fire design basis; seam type, seam height, panel width, pan stiffening, slope, and panel length; base metal, gauge, metallic coating, and finish; clips, fasteners, seam sealant, and closures; the underlayment and ice barrier beneath panels on a solid deck and the thermal spacer blocks over purlins; panel-integrated eave, rake, ridge, hip, valley, and transition trim; pipe penetrations, curbs for roof hatches, smoke vents, and skylights, translucent panel inserts, and snow retention; laboratory and field testing; installation; and the workmanship, finish, and weathertightness warranties.
- Metal Wall Panels
Exterior metal cladding installed on the above-grade wall enclosure of commercial, institutional, and multifamily buildings. Covers the four principal panel families — factory-foamed insulated metal panels (IMP), single-skin formed and profiled panels, metal composite material panels (MCM/ACM), and flat plate or cassette panels — installed as concealed-fastener or exposed-fastener systems and, where specified, as pressure-equalized or drained-and-back-ventilated rainscreens. Addresses the air, water, structural, thermal, and fire performance the assembly shall demonstrate; the metal substrate and its gauge or thickness; the core and insulation type; the coil and panel finishes with their weathering warranties; the attachment, sub-girt, and support framing; the panel joints and sealants; the interface to flashing, trim, and the air/water barrier behind the panel; and the laboratory and field testing that verifies the installed wall. Addresses the NFPA 285 fire-propagation triggers in the IBC that govern combustible-core panels on Type I through IV construction.
- Roof Hatches and Smoke Vents
Factory-fabricated roof hatches and gravity smoke and heat vents installed through the roof deck on commercial, industrial, warehouse, distribution-center, and institutional buildings. Covers single- and double-leaf personnel and equipment access hatches, dome-type and double-skin gravity smoke and heat exhaust vents, fire-rated hatch assemblies, and the complete unit including curb, cover, hardware, factory insulation, and integral flashing collar. Applies where IBC Section 910 mandates gravity smoke and heat venting and wherever code or program requires roof access.
- Roof Specialties and Copings
Factory-engineered, catalog manufactured roof specialty components at the perimeter and termination of low-slope (≤ 3:12) commercial, institutional, and light-industrial roofs — manufactured coping cap systems (concealed-cleat snap-lock or face-fastened), gravel stops and fasciae, counterflashing reglet systems, roof expansion-joint covers, and scuppers and overflow assemblies, supplied as ANSI/SPRI/FM 4435/ES-1 wind-uplift tested and labeled proprietary assemblies in prefinished steel, aluminum, copper, or zinc, for new construction and re-roofing.
- Self-Adhering Sheet Waterproofing
Factory-adhesive (peel-and-stick) sheet waterproofing membranes installed above grade and on horizontal decks that enclose or protect occupied space: plaza, podium, and amenity decks, split-slab and topping-slab assemblies, parking and vehicular decks beneath a separate wearing slab, balconies, terraces, and exterior walkways over enclosed space, planters bearing on those decks, sheet membranes beneath mortar beds and topping slabs in interior wet areas, and full-coverage sheet membranes over steep-slope roof decks where the sheet is the waterproofing plane rather than an underlayment component of the roof covering. Covers rubberized asphalt, reinforced SBS-modified bitumen, butyl, and non-bituminous self-adhered sheets, service temperature rating, thickness and ply count, primer, substrate preparation on concrete, wood sheathing, and gypsum sheathing, application temperature limits, laps and rolling, terminations, drains and penetrations, the protection course, the drainage layer and overburden, the transition to the wall water-resistive barrier, field watertightness testing, and warranty.
- Sheet Metal Flashing and Trim
Shop- and field-formed architectural sheet metal that closes the building envelope at interfaces - copings on parapets, gravel stops, fasciae and drip edges at roof edges, counterflashings over membrane base flashings, through-wall and head and sill flashings, gutters, downspouts, scuppers and conductor heads, expansion joint covers, and closure and reveal trim. Covers zinc-coated and aluminum-zinc alloy-coated steel, aluminum, stainless steel, copper, and architectural zinc; coil-applied and anodized finishes; forming, hemming, seaming, soldering, and welding; thermal movement and expansion joint provisions; wind securement of low-slope roof edges to ANSI/SPRI ES-1; fastener, cleat, sealant, and underlayment selection; and galvanic separation of dissimilar metals.
- Skylights and Unit Skylights
Factory-assembled unit skylights and tubular daylighting devices rated as complete products under the North American Fenestration Standard and set into the roof plane of commercial, institutional, industrial, multifamily, and residential buildings. Covers curb-mounted, deck-mounted (self-flashing), ridge, and continuous-run units, roof windows on a slope above the weather line, fixed units, manually and electrically operated units including operable skylights opened for smoke exhaust, and tubular daylighting devices; the glazing infill of the unit, whether formed acrylic or polycarbonate with its IBC Chapter 26 combustibility class or an insulating glass unit with the laminated inboard lite or retention screen IBC Chapter 24 requires; the factory curb, integral flange, and factory flashing kit; condensation gutters and weeps; insect screens, fall-protection screens, and the fall-protection rating of the unit; performance class and grade, air leakage, water penetration, impact resistance, condensation resistance, U-factor, solar heat gain coefficient, and visible transmittance; field water testing; and the manufacturer and installer warranties. Applies to new units and to replacement units set into existing openings.
- Through-Wall Flashing and Masonry Moisture Control
Design and installation of drainage-plane through-wall flashings built into masonry veneer, brick cavity walls, CMU backup, and mixed-cladding assemblies to intercept water that penetrates the outer wythe and redirect it to the exterior, with the paired weep/vent and cavity-drainage systems. Covers base-of-wall, lintel/shelf-angle, sill, head, and parapet conditions in new commercial, institutional, and multi-family construction and in masonry rehabilitation where existing flashing has failed or is absent.
- Vapor Retarders
Dedicated vapor retarder products installed in above-grade framed and furred wall assemblies, in the ceiling plane below a vented attic, and in framed roof assemblies with cavity insulation, in commercial, institutional, multifamily, and residential buildings. Covers the vapor retarder class the adopted code requires for the climate zone and assembly, the position of the retarder within the assembly, the products that provide it (polyethylene sheet, reinforced polyethylene sheet, foil-laminate sheet, variable-permeance membranes, and vapor retarder coatings on gypsum board), seams, penetrations and electrical boxes, perimeter terminations, the retarder's optional role as the interior air barrier, inspection before concealment, and warranty.
- Vegetated (Green) Roofing
complete vegetated (green) roof assemblies over the waterproofing plane on commercial, institutional, and residential buildings - extensive (growing medium ≤6 in.), semi-intensive (6-10 in.), and intensive (>10 in. up to 48 in.) types on low-slope roofs (≤15%), podium decks, and plaza decks. Covers root-resistant waterproofing (or separate root barrier), protection/slip sheet, drainage/retention layer, filter fabric, engineered growing medium, and plant material, as modular tray or built-in-place assemblies, for new construction and re-roofing where stormwater management, heat-island reduction, or occupied green space is a project objective.
Architectural
Finishes
(19)
- Acoustic Ceiling Clouds and Baffles
free-hanging sound-absorbing clouds, baffles, and canopy assemblies independently suspended from structural decks or exposed structure in open-plenum commercial interiors - open offices, education spaces, healthcare waiting and corridors, hospitality, and performing-arts venues - where a full suspended acoustical ceiling is impractical or aesthetically undesired. Covers horizontal floating clouds, vertical baffles and blades, hybrid canopies, suspension hardware, fire classification, acoustical performance, and coordination with sprinklers, MEP, and seismic bracing.
- Acoustic Wall and Ceiling Panels
Prefabricated, surface-applied, and suspended sound-absorptive panels whose face is exposed to view and whose primary function is sound absorption in occupied commercial, institutional, educational, healthcare, and performing-arts spaces — including fabric-wrapped fiberglass and mineral-wool panels, perforated-metal panels with absorptive infill, wood-slat and wood-veneer acoustic panels, PET/recycled-fiber panels, foam panels, ceiling clouds, baffles, and banners.
- Carpet
Tufted, woven, fusion-bonded, and needle-punched carpet in modular tile and broadloom formats installed over concrete, wood panel, and raised access floor substrates in commercial, institutional, healthcare, educational, hospitality, and multi-family interiors. Covers format and construction, pile configuration, face fiber and dye method, face weight, pile thickness and density, appearance retention, tuft bind and delamination strength, modular tile and broadloom backings, critical radiant flux and smoke density, static control, colorfastness, low-emitting and sustainability certification, accessibility of the walking surface, substrate acceptance for carpet including concrete moisture and alkalinity testing and mitigation, releasable adhesive, direct glue-down, double-glue, and stretch-in attachment, separate cushion, seaming, transitions, field inspection, cleaning, warranty, and attic stock.
- Cementitious Self-Leveling Underlayment
Portland-cement-based, polymer-modified self-leveling floor toppings applied over concrete, wood, or existing resilient substrates to produce a flat, smooth, level surface in preparation for finish flooring; new construction and renovation in commercial, institutional, multifamily, and light industrial work where tolerances finer than FF 25 (3/16 in. in 10 ft) are required; bonded and unbonded pours from feather-edge to 3 in., primer selection, substrate preparation, moisture mitigation, and encapsulation of in-floor radiant heating elements.
- Ceramic Tile
Ceramic, porcelain, quarry, glazed wall, and mosaic tile, and gauged porcelain tile panels and slabs, installed by the thin-bed (thin-set) method over interior and protected exterior floors, walls, wainscots, tub and shower surrounds, and countertops in commercial, institutional, healthcare, educational, hospitality, and multi-family construction. Covers tile selection and water-absorption classification, slip resistance, setting materials (dry-set and modified mortars, organic adhesive, epoxy), bonding mortar selection by substrate, crack-isolation and waterproof membranes, grout type selection (cementitious and epoxy), movement-joint design, substrate preparation and flatness, large-format and gauged-panel installation, field testing, and warranty.
- Entrance Flooring and Walk-Off Systems
Permanently installed entrance flooring and walk-off systems that capture moisture, soil, grit, and snowmelt from foot and rolling traffic at building entrances before it reaches the interior finish floor. Covers recessed and surface-mounted rail grilles with replaceable tread inserts in lift-out, hinged, and roll-up construction, recessed and surface-mounted link and modular mats, and walk-off carpet tile and broadloom in the interior wiper zone. Addresses the arrangement of the exterior scraper, threshold scraper-wiper, and interior wiper zones, walk-off length, rail and frame materials, recess depth and drainage, rolling load rating, tread inserts, accessibility of the walking surface, slip resistance, flammability and low-emitting requirements for textiles, installation, cleaning, warranty, and attic stock.
- Epoxy Floor Coatings
thin-film to medium-build two-component epoxy floor coatings (100% solids, solvent-borne, or waterborne) applied by roller or squeegee over prepared concrete slabs for protection and appearance in commercial, institutional, and light-to-medium duty industrial spaces — back-of-house corridors, mechanical and electrical rooms, storage and warehouse floors, school gymnasiums and corridors, light-duty institutional kitchens, light manufacturing, and pedestrian parking decks; dry film thicknesses from roughly 3 mil (waterborne sealer) to 30 mil (high-build or broadcast decorative systems); single-coat sealers, two-coat base/topcoat systems, vinyl-chip and color-quartz broadcast systems, and aliphatic polyurethane or polyaspartic topcoats over epoxy.
- Exterior Painting and Coatings
Field-applied decorative and protective coating systems on the exterior architectural substrates of commercial, institutional, and multi-family residential buildings: cast-in-place and precast concrete, concrete masonry, portland cement plaster (stucco), hollow metal doors and frames, miscellaneous metals and metal fabrications, exposed structural steel over its shop primer, galvanized steel including the factory-primed curtains and sections of coiling and sectional doors, aluminum and other non-ferrous metals, wood siding, trim, soffits, and doors, fiber-cement siding and trim, and previously painted exterior surfaces. Covers the finish and primer chemistry for each substrate (acrylic latex, elastomeric, high-build acrylic, waterborne acrylic-epoxy, mineral silicate, alkyd, waterborne acrylic-urethane, two-component aliphatic polyurethane, and the opaque, semi-transparent, and clear finishes for wood), surface preparation grades, substrate moisture and cure, application weather limits, sheen, number of coats and film thickness, color matching, volatile organic compound limits, mildew resistance, anti-graffiti coatings, mock-ups, field verification of thickness and adhesion, touch-up, warranty, and extra stock.
- High-Performance Coatings
Field-applied protective coating and lining systems selected for the service a surface sees rather than for its appearance: chemical splash and spill, immersion in water, wastewater, sludge, or chemicals, the hydrogen sulfide vapor space of wastewater structures, industrial washdown, abrasion, and the interior and exterior atmosphere of a water, wastewater, chemical, food, pharmaceutical, or industrial facility. Covers the field finish system over the shop primer, shop epoxy, or galvanizing of exposed process piping, valves, gates, actuators, pumps, equipment, structural steel, metal fabrications, gratings, and miscellaneous metals where the service demands more than architectural paint; the coating of exposed plastic piping for ultraviolet protection and identification; thin-film and high-build coatings on concrete, masonry, and gypsum board walls and ceilings in washdown and chemical rooms; linings of concrete and steel structures in immersion, wastewater, and chemical service that are not furnished with equipment; and secondary containment linings. Covers the service classes, the surface preparation grades and profiles for steel, galvanizing, plastic, and concrete, moisture and soluble salt limits, the generic primer, intermediate, and finish coat of each system and its dry film thickness, holiday, adhesion, and thickness verification, applicator and inspector qualification, color, gloss, and flame spread, volatile organic compound limits, cure before service, warranty, and extra stock.
- Interior Painting
Field-applied surface preparation, primers, and finish coatings on interior architectural substrates — gypsum board, plaster and veneer plaster, concrete, concrete masonry, ferrous and galvanized metal, and interior wood — in commercial, institutional, and multi-family residential buildings. Covers latex, alkyd, and water-based epoxy paint systems applied to walls, ceilings, doors and frames, exposed structure, and exposed mechanical and electrical work that is to be field-painted.
- Metal Ceiling Panels
interior architectural ceilings and exterior soffit cladding built from formed or pan-style metal panels (aluminum or steel) in commercial, institutional, hospitality, retail, and transportation spaces — lay-in metal pan tiles in suspended grid, linear/plank systems on concealed carriers, concealed-fastener cassettes, and perforated panels with acoustic backers for lobbies, concourses, terminals, transit stations, canopies, parking structures, and high-humidity or food-processing environments where mineral-fiber tile is unsuitable.
- Natural Stone Tile
Interior and protected exterior natural dimension-stone tile, cut-to-size stone, and gauged thin stone slab — granite, marble, limestone, travertine, slate, quartzite, sandstone, serpentine, onyx, soapstone, and basalt — set on floors, walls, wainscots, stair treads and risers, thresholds, base, and countertops. Covers stone type and the governing ASTM dimension-stone material specifications, physical-property and abrasion testing, slip resistance, form, dimensions, and surface finish, pattern and vein match, setting method and bonding mortar, crack-isolation and waterproof membranes, joint filler and joint width, movement-joint design, substrate preparation and moisture, installation, field inspection, cleaning, and sealing.
- Polished Concrete Flooring
Mechanically ground, honed, and polished concrete floor finishes produced in place by progressive bonded-abrasive diamond processing of a structural or topping concrete slab, including chemical densification and optional coloring with dye or stain. Covers true bonded-abrasive polishing (full grind-hone-polish to a measured gloss and clarity), grind-and-seal finishes, and burnished guard finishes; aggregate exposure selection (cement fines, fine aggregate, coarse aggregate), gloss and clarity levels, densifier chemistry, joint and crack filling, slip resistance, abrasion resistance, and the coordination required to protect a finished slab that is also the building's structural floor.
- Resilient Flooring
Interior resilient floor coverings and resilient wall base in commercial, institutional, healthcare, educational, hospitality, and multi-family construction: luxury vinyl tile and plank, rigid core vinyl plank, vinyl composition tile, homogeneous and heterogeneous sheet vinyl, rubber tile and sheet, sheet and tile linoleum, resilient wall base, resilient stair treads, transition strips, and the adhesives, seam welding, integral flash cove, and static control grounding that go with them. Covers product type and class, wear layer and overall thickness, critical radiant flux and smoke density, slip resistance, static load, chemical resistance, low-emitting materials, static control resistance, substrate acceptance including concrete moisture and alkalinity testing and topical moisture mitigation, full-spread adhesive, loose lay, and floating installation, heat and chemical welding, field inspection, initial finish, cleaning, warranty, and attic stock.
- Resinous Flooring
Fluid-applied, seamless resinous floor finishes installed over concrete in commercial, institutional, industrial, food and beverage, healthcare, laboratory, and cleanroom applications. Covers epoxy, polyurethane, cementitious urethane (urethane mortar), methyl methacrylate (MMA), and polyaspartic resin chemistries; thin-film coating, broadcast (sand, quartz, or vinyl flake) media, and trowel-applied mortar system types; slip resistance, chemical and thermal-shock resistance, abrasion, and electrostatic-dissipative and conductive (ESD) systems; concrete surface preparation and profiling, moisture testing and topical moisture mitigation, integral cove base, and seamless wall-to-floor detailing.
- Suspended Acoustical Ceilings
Direct-hung metal suspension grid systems and acoustical panels or tiles — both exposed-tee lay-in and concealed-spline — for commercial, institutional, healthcare, educational, and hospitality interiors. Covers the suspension grid (type, profile, duty classification, and finish), acoustical panels (material, size, edge detail, and surface texture), acoustical performance (NRC and CAC), light reflectance, surface-burning fire performance, fire-resistance-rated ceiling membrane assemblies, seismic restraint and perimeter treatment, hold-down clips, trim and moldings, hanger wire and bracing, and integration with light fixtures, air devices, and sprinkler heads.
- Terrazzo
Poured-in-place terrazzo floor and base finishes for commercial, institutional, civic, educational, healthcare, and transportation interiors — epoxy (resinous) thin-set terrazzo and the cementitious systems (polyacrylate, monolithic, bonded, and sand-cushion). Covers matrix system selection, marble/granite/glass/recycled aggregate, divider and control strips, substrate flatness and moisture testing, physical-property requirements for the resin matrix, crack-isolation and joint detailing, grinding/grouting/polishing/sealing, integral cove and topset base, and precast terrazzo bases and stair treads. Suitable for new construction and for terrazzo restoration where the existing system is sound.
- Wall Coverings
Flexible wall coverings applied to interior wall and ceiling surfaces in commercial, institutional, healthcare, hospitality, education, and multi-family residential construction — vinyl-coated fabric (Type I, II, and III per ASTM F793), textile and natural-fiber coverings, cork, and digitally printed coverings. Covers use-type and durability selection, facing material, fire-performance classification, adhesive selection, substrate preparation, seam treatment, moisture-vapor control, low-emitting certification, and finished-surface performance for new construction and renovation.
- Wood Flooring
Interior wood finish flooring — solid sawn strip and plank, engineered multi-ply flooring, parquet tile and block, end-grain block, and maple sports flooring — installed over wood framing, wood panel subfloors, and concrete slabs above, on, and below grade. Covers construction, species, cut, grade, and dimension selection; in-service interior climate and acclimation criteria; concrete and wood substrate moisture testing and moisture control; nail-down, staple-down, adhesive, and floating attachment; factory-applied and site-applied finish systems; expansion provisions; fire and emissions requirements; and field verification, maintenance, and warranty provisions.
Openings
(16)
- Access Doors and Panels
Architectural access doors and panels set into walls and ceilings to provide concealed, repeatable access to valves, dampers, cleanouts, junction boxes, shutoffs, and other serviceable equipment hidden behind a finished surface. Covers panel type by substrate and finish (flush universal for drywall, masonry, and plaster; recessed for tile; recessed for drywall or plaster infill; drywall-bead taping-flange; surface-mount), gasketed and insulated panels for exterior or thermal-barrier locations, fire-rated access doors that are UL or ULC listed and labeled (insulated, self-closing, self-latching, for use in fire-resistance-rated wall and ceiling assemblies under IBC Section 716), security panels with no exposed hardware, materials and gauges (cold-rolled and galvannealed steel, stainless steel, aluminum), frame types for each substrate, latch and hinge selection, prime and factory finish, sizing for the largest serviceable component, accessibility of operable parts, and coordination so a panel is provided wherever a concealed device requires service.
- All-Glass Entrances and Doors
frameless all-glass entrance assemblies for commercial, institutional, and high-end retail lobbies where a fully glazed, frame-free appearance is required — single and double swing doors, sliding all-glass panels, and folding systems fabricated from monolithic tempered or tempered laminated glass supported entirely by patch fittings, rail systems, pivots, floor closers, and overhead concealed closers, for interior and exterior storefront-type openings in new construction and renovation.
- Aluminum Entrances and Storefronts
Non-load-bearing extruded aluminum framing systems glazed with monolithic or insulating glass, and the aluminum stile-and-rail swing entrance doors integrated with them, at building perimeters and interior partitions. Covers framing depth, sightline, joinery, glazing pocket position, and thermal barrier construction; glass lite construction, insulating glass unit make-up, edge seal, and low-emissivity coatings; dry, wet, and structural silicone glazing methods; air infiltration, water penetration, structural wind load, thermal transmittance, solar heat gain, condensation, acoustic, windborne debris, and inter-story drift performance; entrance door leaf proportions, construction, hardware, thresholds, and weatherseals; anodic and organic finishes; perimeter anchorage, sill water management, and air and water control layer continuity; laboratory and field testing; installation, cleaning, protection, and warranty.
- Automatic Entrance Doors
Power-operated, full-energy automatic pedestrian entrance door systems at commercial, institutional, retail, healthcare, and public building entries — sliding (single-slide, bi-part, telescoping), full-energy automatic swing, and folding assemblies, with their operators, activation and safety sensors, guide rails, thresholds, framing, and integral glazing, for interior and exterior entries that open on approach or by a knowing act.
- Door Hardware
Finish hardware for swinging door openings specified and furnished as its own package, separate from the door leaves and the frames, in commercial, institutional, educational, healthcare, hospitality, and multi-family residential work. Covers the hardware schedule and numbered hardware sets as the coordination instrument; ANSI/BHMA operational grades; butt hinges, continuous hinges, pivots, and self-closing hinges; bored, mortise, interconnected, and tubular locksets and latches, auxiliary locks, and trim; cylinders, interchangeable cores, keyway control, keying hierarchy, construction keying, and key control; panic hardware and fire exit hardware; door closers, overhead stops and holders, and fire-alarm-released hold-open devices; door stops, silencers, protection plates, and push and pull trim; coordinators, flush bolts, and removable mullions at pairs; thresholds, weatherstripping, smoke and acoustic gasketing, intumescent edge seals furnished under the hardware sets, and automatic door bottoms; patch fittings, rails, pivots, locks, and closers for all-glass swing doors in interior partitions; electrified locks, strikes, exit devices, electromagnetic locks, delayed egress devices, and the power transfer into the leaf; low-energy power-operated and power-assist swing door operators under ANSI/BHMA A156.19 with their knowing-act actuators; hardware finishes; accessible-opening obligations; installation, adjustment, field verification, fire door acceptance inspection, warranty, and spare parts.
- Doors, Frames, and Hardware
Swinging door openings furnished as one combined package of hollow metal doors and frames, architectural wood flush doors, and finish hardware, in commercial, institutional, and light-industrial construction. Covers the opening schedule as the coordination instrument; hollow metal performance levels, models, face-sheet materials, cores, frame thickness, profile, construction method, anchorage, grout fill, and factory finish; wood door duty levels, appearance grades, cores, face materials, veneer selection and matching, edges, and finishing; fire-rated and smoke-rated listed assemblies under NFPA 80, NFPA 105, and UL 10C; hinges, locksets, exit devices, closers, stops, protection plates, thresholds, and gasketing; cylinders, keyways, and keying hierarchy; electrified hardware, fail modes, power transfer, and fire alarm release; accessible-opening obligations; installation tolerances and clearances; fire door inspection at turnover; and warranty.
- Fire-Rated Glazing and Framing
vision glass set into fire-resistance-rated walls and partitions as a listed opening protective — fire-protective glazing (20-90 min, resists flame and hot gases) and fire-resistive glazing (45-120 min, also limits radiant heat) with their complete tested steel, aluminum, or composite framing systems. Covers fire-rated windows, sidelights, transoms, full-height rated glass walls, and the glazed infill within fire-rated door leaves in fire barriers, fire partitions, fire walls, corridor walls, and exit enclosures.
- Glass and Glazing
Architectural vision glass and glazing for storefronts, curtain walls, windows, exterior and interior doors, sidelights, transoms, borrowed lites, partitions, and other building glazing infill. Covers annealed, heat-strengthened, and fully tempered flat glass; laminated glass; coated (low-emissivity and solar-control) glass; insulating glass units (IGUs) including double and triple makeups; spandrel and ceramic-frit glass; safety glazing in hazardous locations per the International Building Code; glass strength and thickness determination under wind and snow load per ASTM E1300; thermal stress and edge-condition selection of annealed versus heat-strengthened versus fully tempered glass; nickel-sulfide heat-soak treatment for tempered glass; low-iron glass; warm-edge spacers and inert-gas fill; structural silicone and dry-gasket glazing methods; setting blocks, edge clearances, and glazing accessories; and field installation, testing, cleaning, and warranty of the glass and glazing materials.
- Glazed Curtain Walls
Aluminum-framed glazed curtain wall acting as the primary non-load-bearing exterior enclosure of a building — stick-built, semi-unitized, and unitized systems that span vertically across one or more stories and hang from the building frame at discrete anchors. Covers the assembly method, the water management principle and internal drainage, mechanically captured and structurally silicone-glazed retention, framing member sizing and thermal barriers, the vision and spandrel glazing selection tree the framing delivers, aluminum finishes, air and water penetration resistance, thermal transmittance and condensation resistance, acoustic performance, wind pressure and deflection criteria, thermal and seismic movement accommodation, wind-borne debris impact resistance, perimeter fire containment at the floor edge, anchorage and movement joints, perimeter air and water barrier continuity, fabrication, mockups, erection, and field water and air testing.
- Hollow Metal Doors and Frames
Steel-sheet hollow metal doors and frames for commercial, institutional, industrial, and government openings — flush, seamless, and embossed faces over honeycomb, polystyrene, polyurethane, temperature-rise, or acoustic cores; knocked-down, welded, and slip-on frames; standard through maximum-duty grades (ANSI/SDI A250.8 Levels 1-4); interior and exterior, fire-rated up to 3-hour, acoustic, galvanized, and galvannealed assemblies.
- Interior Glazing and Glass Partitions
interior glass partition systems and borrowed lites in commercial office fit-outs, institutional buildings, and tenant improvements — full-height and partial-height framed aluminum, frameless structural-silicone-set, and clip/patch-fitting glass walls; fixed sidelites and clerestory/borrowed lites adjacent to interior doors and corridors; single-pane tempered, laminated, and insulating-glass-unit configurations in non-load-bearing interior framing, where the driver is daylighting, visual openness, and acoustic separation — not exterior weathering.
- Overhead Coiling Doors
Opaque overhead coiling doors and coiling counter doors whose curtain of interlocking metal slats rolls onto a counterbalanced barrel above the opening, at service, dock, drive-through, parking, equipment-room, corridor, and counter openings in commercial, institutional, and industrial work. Covers non-insulated and insulated service doors, counter doors and counter shutters, and fire-rated coiling doors and counter shutters listed under NFPA 252 or UL 10B; design wind pressure, windborne-debris impact rating, thermal transmittance, and air leakage; fire-protection rating, release, governed closing, reset, and smoke and draft control listing; curtain slat construction, material, gauge, insulation, and vision; bottom bar, guides, brackets, barrel, counterbalance, and hood; weatherseals and locking; counter door sills and frames; push-up, chain hoist, crank, and motor operation with UL 325 entrapment protection, control mode, interfaces, enclosure type, and emergency manual operation; factory finishes; installation, anchorage, perimeter sealing, acceptance testing including the NFPA 80 drop test, warranty, and spare parts.
- Overhead Coiling Grilles
upward-coiling open-mesh curtain assemblies (rolling grilles, security grilles) for storefronts, shopping-mall closures, interior tenant separation, parking entries, and light-duty industrial openings where the closed assembly must remain visually open and ventilated. Covers non-rated and fire-rated, manual and motorized, standard and high-cycle models in galvanized steel, aluminum, and stainless steel.
- Sectional Overhead Doors
Upward-acting sectional overhead doors whose horizontal panels (sections) hinge together and track horizontally beneath the ceiling when open, serving loading docks, drive-through service openings, parking garages, warehouses, and light-industrial buildings. Covers insulated (foamed polyurethane sandwich), non-insulated (ribbed or pan steel), and full-vision aluminum-and-glazing doors; panel material, gauge, thickness, and finish; vision lites and glazing; weatherseals and air-infiltration class; torsion and extension counterbalance and cycle-life rating; track and lift configuration selected by available headroom and sideroom; wind-load design pressure and reinforcement; manual chain-hoist and motor operation with UL 325 entrapment protection; installation, field testing including the safety-reverse test, and warranty.
- Windows
Complete factory-assembled, single-manufacturer window units in any frame material (aluminum, vinyl, wood, clad-wood, fiberglass, composite) and any operating type (fixed, double-hung, single-hung, casement, awning, hopper, sliding, projected, tilt-turn) for new construction and replacement work in low-rise residential, mid-rise multifamily, and commercial buildings. Covers NAFS performance classification, thermal and structural ratings, glazing and frame selection, finish, hardware, egress, impact resistance, and installation per ASTM E2112.
- Wood Doors
Factory-built architectural wood door leaves specified as their own package, separate from the frame and the finish hardware, for interior and exterior swinging openings in commercial, institutional, educational, healthcare, hospitality, and multi-family residential work. Covers flush doors to ANSI/WDMA I.S.1A and stile-and-rail doors to ANSI/WDMA I.S.6A; performance duty level and appearance grade; hollow, particleboard, structural composite lumber, stave lumber, agrifiber, lead-lined, and listed mineral cores; wood veneer, high-pressure decorative laminate, and opaque faces; veneer species, cut, grade, and matching; edge construction; stile, rail, and panel construction; exterior-service construction; fire-protection and smoke-control listings for the leaf, positive-pressure edge seal category, lite and louver cutouts; sound-rated leaves; factory finishing, composite-wood emissions, and chain-of-custody certification; factory machining, blocking, and raceway for hardware; delivery, storage, installation clearances, field trimming, acceptance tolerances, warranty, and attic stock.
Specialties
(24)
- Architectural Wood Trim and Paneling
Interior architectural woodwork applied to the building's walls, ceilings, and openings rather than built as cabinets — standing and running trim (base, casing, chair rail, crown, picture mold, and other moldings); wood wall and ceiling paneling in flush, stile-and-rail, and raised-panel configurations; wood slat and linear plank systems, including acoustic slat assemblies; applied and ornamental woodwork; and the transparent or opaque finish that completes them. Covers the architectural woodwork quality grade, the species and cut of solid lumber and decorative veneer, face veneer grade, leaf and assembly matching and panel-to-panel sequencing, panel face and core construction, interior finish fire classification and fire-retardant treatment, composite-wood formaldehyde compliance, adhesives, finish system and finishing location, service humidity and wood moisture content, concealed blocking and hanging systems, joinery, and movement provisions.
- Code-Required Signage and Egress Markings
The non-illuminated signs whose message, location, and tactile form are prescribed by the means-of-egress and accessibility provisions of the adopted building code, NFPA 101 where it is in force, and ICC A117.1, in new construction and alterations of commercial, institutional, assembly, educational, healthcare, hospitality, industrial, and multi-family residential buildings. Covers tactile exit signs with raised characters and Braille at exit doors, exit stair doors, exit passageway doors, and exit discharge doors; stairway identification signs and the tactile floor-level signs inside exit stairways, including roof-access and stair re-entry statements; area of refuge identification signs, the instruction signs at two-way communication stations, and directional signs to an accessible means of egress; the elevator emergency-use sign at each call station and the raised floor designations on hoistway jambs; occupant load postings and their holders; NO EXIT signs; the notice sign the code requires at a main exit door secured with a key-operated lock; the fabrication process, plate material, characters, Braille, contrast, and mounting of every raised-character sign in this set; mounting height and location; field verification; warranty; and spares.
- Demountable Partitions
Factory-fabricated, relocatable panel-and-frame partition systems for interior commercial, institutional, and industrial fit-outs where walls must be reconfigured without major demolition — solid opaque panels, full- and partial-height glazed panels, and combination assemblies with their framing, floor runners, head tracks, integrated door frames, utility pathways, and accessories. Typical in office tenant improvements, corporate interiors, healthcare clinics, education, and retail fit-outs where repeated reconfiguration or future subletting is the design intent.
- Elevators
Factory-engineered passenger and service elevators for new construction and full replacement, covering hydraulic elevators with holed, holeless and roped jacks and traction elevators with machine-room-less, overhead and basement machine arrangements. Covers drive and machine selection, the controller and group operation, door operators, entrances and door protection, the car enclosure and its finishes, hall and car signal fixtures, accessibility of the car and its fixtures, firefighters' emergency operation and its interface with the fire alarm system, operation on standby power and battery-powered rescue operation, elevator seismic provisions, the requirements the hoistway, pit, machine room and electrical service must meet for the equipment, acceptance inspection and testing, maintenance during the warranty period, and the diagnostic access the Owner keeps afterward. The equipment is governed by ASME A17.1/CSA B44 and inspected under ASME A17.2; rated load, rated speed, car size, number of stops and number of cars come from the elevator traffic study and the drawings and are deferred, never selected here.
- Exterior Signage
Furnishing and installation of building-exterior and site signage on commercial, institutional, and mixed-use projects — ground-mounted monument signs (single- and double-faced), pylon and pole signs, channel-letter and dimensional-letter signs (illuminated and non-illuminated), cabinet and panel signs, post-and-panel wayfinding arrays, tenant directory signs, facade-mounted building-identification signs, and code-required exterior identification signs (ADA building IDs, accessible-route markers, exit-discharge signs). Covers structural and foundation integration, electrical service coordination, materials and finishes, UL listing, wind-load compliance, permit documentation, and ADA/IBC compliance for each sign type.
- Flagpoles
Exterior flagpoles for commercial, institutional, governmental, civic, campus, park, and sports-facility projects: freestanding ground-set, shoe-base, and hinged-base poles; wall-mounted vertical and outrigger poles; and roof- or canopy-mounted poles, in aluminum, fiberglass, steel, or stainless steel, as single poles or coordinated groups. Covers structural design under wind and flag load to ANSI/NAAMM FP 1001, shaft material and profile, external and internal halyard systems and their security, trucks and finials, finishes and corrosion exposure, the foundation and foundation tube, wall and roof mounting, grounding and lightning-protection provisions at the pole, raceway provisions for flag illumination, installation, and warranty.
- Foodservice Equipment
Selecting and installing commercial foodservice equipment in commercial kitchens, cafeterias, commissaries, institutional dining, restaurants, and food-hall tenant improvements. Covers built-in and freestanding cooking equipment, hot-holding and warming units, warewashing systems, powered food-preparation equipment, point-of-use refrigeration (reach-in, under-counter, prep tables, blast chillers), ice machines, beverage and dispensing equipment, and custom stainless-steel fabrications, including utility rough-in coordination and NSF/UL/ETL listing requirements.
- Interior Architectural Woodwork
This is the coordinating umbrella standard for interior architectural woodwork on commercial, institutional, hospitality, healthcare, and civic fit-out projects where the millwork package combines multiple AWI-graded product types under a single millwork contract — custom shop-fabricated paneling, standing and running trim, specialty casework, freestanding built-ins, ornamental woodwork, display and library shelving, wainscot and wall-cladding systems, decorative columns, pilasters, and bespoke integrated assemblies (reception environments, boardroom paneling packages, liturgical woodwork, exhibit casework). Covers AWI Quality Certification Program (QCP) project certification, shop-drawing coordination across all woodwork types, acclimatization, and delivery sequencing for large-package contracts. Each product is governed by an AWI quality grade (Economy / Custom / Premium).
- Laboratory Casework
Laboratory-grade casework and the work surfaces, sinks, and service fittings mounted on it, for teaching, research, clinical, analytical, and industrial laboratories in new construction and renovation: fixed, suspended, mobile, and adaptable base, wall, and tall cabinets in painted steel, stainless steel, phenolic resin, polypropylene, wood, and plastic laminate graded under the SEFA 8 recommended practices; epoxy resin, phenolic resin, chemical-resistant laminate, stainless steel, polypropylene, soapstone, and ceramic work surfaces, curbs, and reagent shelving; laboratory sinks and cup sinks; SEFA 7 water, purified-water, gas, air, and vacuum fittings and the electrical service raceways carried on the casework; flammable liquid and corrosive storage cabinets, including the base cabinets fume hoods sit on; accessible laboratory stations; seismic anchorage; installation; warranty; and spare parts.
- Loading Dock Equipment
Specifying, selecting, and installing the full assembly of equipment at truck-height loading docks — dock levelers (mechanical, hydraulic, air-powered, vertical-storing, edge-of-dock), portable dock plates and boards, dock bumpers, dock seals and shelters, vehicle/trailer restraints, and the electrical interlock and dock-light system that ties them together. Applies to distribution centers, warehouses, cold-storage facilities, retail and institutional receiving docks, food and beverage plants, and industrial facilities, for both new dock-pit construction and retrofit at existing openings.
- Metal Canopies and Awnings
exterior overhead metal protective covers — entrance canopies, walkway covers, drive-through lane covers, loading-zone covers, and fuel/gas-station island canopies on commercial, institutional, industrial, and multi-family residential buildings. Covers pre-engineered and custom-fabricated systems with steel or aluminum framing, metal deck or panel roofing, integral or scuppered drainage, fascia, soffit liners, and anchorage, in cantilever, column-supported, wall-bracket, and suspended (cable/rod) configurations with powder-coat, anodized, PVDF, or galvanized finishes.
- Metal Lockers
Factory-fabricated sheet-steel lockers and their doors, latching, locking, trim, interior equipment, and anchorage, in knocked-down or welded construction, for school corridors, athletic and team rooms, employee and industrial change rooms, public recreation, and day-use storage. Covers substrate selection and corrosion protection, component sheet thickness, tier and opening configuration, door ventilation, latching and locking including electronic locks, powder-coat finish performance, tops, bases and closure trim, accessible lockers under the ADA Standards and ICC A117.1, and floor, wall, and seismic anchorage.
- Operable Partitions
top-hung manually or electrically operated movable wall systems used to subdivide assembly, educational, hospitality, and conference spaces into smaller rooms; includes individual-panel, paired-panel, continuously hinged accordion, and motorized vertical-fold systems with specified acoustic (STC) and fire-resistance ratings.
- Plastic Lockers
solid plastic lockers — high-density polyethylene (HDPE) and compact solid phenolic — for high-moisture, high-hygiene, or high-vandalism environments such as aquatic centers, natatoriums, pool and spa locker rooms, athletic and fitness facilities, country clubs, food-service staff areas, and healthcare locker rooms where steel would corrode or delaminate. Covers locker bodies, doors, frames, shelving, hardware, tier arrangements (single through six-tier and Z-tier), integrated and freestanding benches, and anchorage.
- Raised Access Flooring
rigid grid raised access floor systems for data centers, computer rooms, command and control centers, electronics manufacturing, equipment rooms, and offices requiring an accessible underfloor plenum for cabling, power distribution, or underfloor air distribution (UFAD).
- Signage
Interior and building-mounted architectural and code-required signage for commercial, institutional, and light-industrial buildings — tactile room-identification signs, directional and overhead wayfinding signs, regulatory and informational panel signs, dimensional letters and logos, code-required egress and accessibility signage (exit, stairway identification, floor-level, area-of-refuge), and both non-illuminated and electrically illuminated signs. Covers accessibility requirements for tactile characters and Braille, visual character legibility, contrast and finish, mounting height and location, substrate and copy methods, the sign and message schedule, and installation.
- Solid Surface and Quartz Countertops
Specification, fabrication, and installation of solid surface (cast acrylic/polyester sheet) and engineered quartz (quartz aggregate with polymer binder) countertops for commercial and institutional horizontal work surfaces - restrooms, breakrooms, laboratories, reception desks, nurse stations, locker rooms, and casework tops across office, healthcare, education, hospitality, and light-industrial projects, including integral and undermount sinks, backsplashes, edge profiles, substrate, and anchorage.
- Toilet and Bath Accessories
Furnished and installed washroom accessories in commercial, institutional, educational, healthcare, hospitality, transit, recreation, and correctional toilet rooms, shower rooms, and locker rooms. Covers grab bars at water closets, showers, and bathtubs, including those that mount to a compartment panel; glass and stainless steel mirrors; paper towel dispensers and combination towel and waste units; electric hand dryers as a product, with their sound level, protrusion, and mounting; soap dispensers, wall-mounted and deck-mounted; sanitary napkin disposals and vendors; waste receptacles; toilet tissue and seat-cover dispensers; baby-changing stations; robe hooks, shelves, and custodial holders; shower curtain rods, curtains, and folding shower seats. Covers the stainless steel alloy, finish, and sheet thickness; surface, semi-recessed, and recessed mounting; grab bar section, surface, and anchorage; vandal-resistant construction, security fasteners, and keying; antimicrobial surface claims; recessed units in fire-resistance-rated walls; the hand-off of anchor patterns and mounting heights to the trades that furnish in-wall backing; and installation, field verification, warranty, and spare parts.
- Toilet Compartments
Factory-fabricated toilet compartments, urinal screens, and dressing screens for commercial, institutional, educational, healthcare, transit, assembly, and correctional restrooms. Covers panel material families including plastic-laminate-faced, solid plastic HDPE, solid phenolic core, powder-coated steel, and stainless steel; panel, door, and pilaster thickness; interior-finish fire performance; mounting styles including floor-anchored and overhead-braced, floor-to-ceiling, ceiling-hung, and floor-anchored without headrail; headrails, pilaster shoes, brackets, hinges, latches, coat hooks, and fasteners; compartment dimensions, panel height, floor clearance, and sightline treatment; and wheelchair accessible and ambulatory accessible compartments under the 2010 ADA Standards and ICC A117.1.
- Visual Display Units
Factory-fabricated writing and pinning surfaces furnished as framed units in commercial, institutional, educational, healthcare, hospitality, and government buildings. Covers markerboards and chalkboards with porcelain-enamel steel, painted steel, tempered glass, high-pressure laminate, and melamine writing surfaces; tackboards with cork, vinyl, fabric, and fiber faces; combination units; enclosed bulletin board cabinets with hinged or sliding glazed doors, locks, header panels, and internal illumination; horizontal and vertical sliding panel units and modular rail-hung panel systems; mobile units on casters; display rails, marker trays, map hooks, and accessories; the frame and trim material and finish; the interior finish fire classification and emissions of the faces and cores; mounting, blocking hand-off, seismic anchorage, accessible reach and protrusion; and installation, field verification, warranty, and spare parts.
- Wall and Corner Protection
factory-fabricated, impact-resistant wall and corner protection applied to interior surfaces and edges to resist damage from wheeled traffic, equipment, and pedestrian impact — corner guards (surface-mounted and recessed), wall guards and crash rails, chair and rub rails, bumper rails, handrail wall guards, and rigid sheet wall protection panels — in healthcare, education, government, institutional, hospitality, transportation, and other high-traffic commercial interiors.
- Window Treatments
Interior window treatments installed for glare control, solar heat control, daylight management, privacy, and room darkening in commercial, institutional, and light-industrial buildings. Covers manual and motorized roller shades with solar screen, room-darkening, and blackout fabrics, dual-roller assemblies carrying two shades on one mounting, and draperies on track systems. Addresses fabric composition, openness factor and solar optical properties, fire performance under NFPA 701 and ASTM E84, low-emitting certification, lightfastness, fungal and antimicrobial performance, roller tube and bracket hardware, fascia and pocket concealment, hembars, manual clutch operation and the cord retention provisions of ANSI/WCMA A100.1, motorized operation and its power, listing, control, and integration, mounting condition and light gap, perimeter light-control channels, accessible operation, field testing, installation, warranty, and spare parts.
- Wire Mesh Partitions
modular freestanding or wall-anchored steel wire mesh enclosures and space-dividing systems, fabricated from welded or woven mesh panels framed in steel angle or tube and bolted to steel posts. Covers tenant storage cages, tool cribs, equipment and electrical-room barriers, data-center and server cages, evidence and weapons storage, and back-of-house secure storage in warehouses, plants, distribution centers, correctional and government facilities — normal- and heavy-duty, partial- and full-height, with personnel swing doors, sliding doors, pass-throughs, and locking hardware.
- Wood and Laminate Casework
Factory-fabricated architectural casework graded under the Architectural Woodwork Standards for commercial, institutional, educational, and healthcare buildings: plastic-laminate, thermally fused laminate, wood-veneer, and solid-wood base, wall, and tall cabinets; reception desks, nurse stations, service and transaction counters, and built-in millwork cabinetry; the plastic-laminate countertops and backsplashes that top them; and the cabinet hardware that operates them. Covers the quality grade, installation grade, and structural duty level; construction type and door and drawer-front interface style; core materials by moisture exposure; exposed and semi-exposed surface materials and laminate grades; veneer species, cut, and matching; edge treatment; plastic-laminate countertop construction; hinges, drawer slides, pulls, locks, and shelf supports; factory finishing; interior finish fire classification; composite-wood formaldehyde and adhesive emissions; accessible stations; blocking, anchorage, and seismic restraint; installation; warranty; and spare parts.
- Acoustic Insulation
Sound-attenuation cavity fill installed in the concealed cavities of interior partitions, in floor-ceiling assemblies, and above suspended ceilings as plenum attenuation, where the purpose of the fill is to raise the airborne sound transmission loss of the host assembly. Covers mineral wool, glass fiber, polyester fiber, and cotton fiber batts, blankets, and boards in that service; the tested-assembly basis that governs what goes in each partition type; fiber family, facing, surface burning, and noncombustibility as project-wide policy; minimum density and fill thickness; retention in vertical and horizontal cavities; plenum attenuation blankets and plenum barriers; installation, inspection before concealment, mock-ups, and field acoustic testing.
- Applied Fireproofing
Spray-applied fire-resistive materials (SFRM) and intumescent fire-resistive materials (IFRM) applied to structural steel, structural concrete, and composite steel deck to achieve hourly fire-resistance ratings required by the International Building Code. Covers cementitious SFRM and mineral-fiber SFRM applied to concealed structural framing, and intumescent mastic and thin-film intumescent coatings applied to exposed-to-view structural steel where architectural finish is required. Addresses surface preparation, primer compatibility, application thickness based on W/D and A/P ratios, density, bond and cohesion/adhesion, in-place verification per AWCI Technical Manual 12-A, ICC-ES AC23 acceptance criteria, and inspection of installed work prior to concealment by ceilings, walls, and finishes.
- Finish Carpentry
Field-installed interior finish carpentry built from stock lumber and stock catalog moldings that are set without shop drawings: base, shoe, casing, jamb extensions, chair rail, crown, picture mold, stool and apron, and other standing and running trim in solid wood, finger-jointed wood, medium density fiberboard, cellular PVC, and foam plastic; stock closet shelving and closet rod; stock wood stair treads, risers, skirtboards, handrails, newels, and balusters set on a stair framed by others; and the field installation, where it is finish carpentry, of items furnished by the Owner or under other standards. Covers the installation grade under ANSI/AWI 0620, species and lumber grade under the hardwood and softwood grading rules, molding grade, finish type and delivery state, moisture content and interior conditions, interior finish fire classification, composite-wood formaldehyde compliance, blocking verification, joinery, fastening, scribing and fitting, delivery and storage, warranty, and attic stock.
- Fire-Resistance-Rated Assemblies
Selecting, documenting, and verifying code-required fire-resistance-rated building assemblies under IBC Chapter 7 — walls, partitions, floor-ceiling and roof-ceiling assemblies, columns, beams, and structural frame members that carry an hourly rating from Table 601/602, occupancy separation, corridor, shaft enclosure, or fire wall/barrier/partition designation. Covers identifying the governing rating, selecting and citing a tested UL/GA design number, substitution rules, continuity, and field verification before concealment.
- Firestopping
Through-penetration firestop systems and fire-resistive joint systems installed in fire-resistance-rated walls, floors, floor-ceiling assemblies, roof-ceiling assemblies, and smoke barriers in commercial, institutional, healthcare, and multi-family construction. Covers tested and listed systems for mechanical, electrical, plumbing, and communications penetrations, head-of-wall and bottom-of-wall joints, wall-to-wall joints, floor-to-floor joints, and floor-to-wall joints. Includes sealants, intumescent and endothermic products, mortars, mineral wool packing, collars, wrap strips, putty pads, composite sheets, and pillow systems. Addresses F, T, L, and W ratings; joint movement classes; identification labeling; installer qualification; field inspection per ASTM E2174 and ASTM E2393.
- Gypsum Board Assemblies
Interior gypsum board partitions, furred walls, and ceilings, and the gypsum sheathing on framed exterior walls, in commercial, institutional, multifamily, and residential buildings. Covers the gypsum panel products by exposure and duty: regular, Type X, and Type C board, sag-resistant ceiling board, mold- and moisture-resistant board, glass-mat faced board, abuse- and impact-resistant board, the wet-area backer boards that carry tile on framed walls, gypsum base for veneer plaster, shaftliner in area separation walls, and glass-mat and paper-faced gypsum sheathing. Covers the nonstructural steel studs, runners, furring, and resilient channels furnished to ASTM C645 and installed to ASTM C754, the suspended and direct-attached ceiling framing that carries gypsum board, deflection heads and partition bracing, in-wall blocking and backing for the trades that hang work on these walls, execution of fire-resistance-rated and sound-rated assemblies to their design numbers, perimeter acoustic sealant and electrical box treatment, fastening, multi-layer application, trim accessories, control joints, joint treatment, levels of finish, and textured finishes.
- Gypsum Shaft Wall Assemblies
Fire-rated, single-side-access gypsum shaft wall enclosures for vertical shafts in commercial and multifamily construction — elevator hoistways, exit stair towers, mechanical/plumbing/duct chases, and pipe or cable risers. Covers the complete proprietary assembly: 1 in. Type X gypsum shaftliner panels friction-fit into light-gauge C-H or E-stud framing with face-layer Type X gypsum board, installed entirely from the building side of the shaft. Applies to 1-hour and 2-hour shaft enclosures in all IBC occupancies, including stairwell and smoke-shaft enclosures using the same system, and addresses framing, shaftliner, face layers, head and base track, deflection-head (J-runner) details, openings, and rated joints within the shaft wall itself.
- Portland Cement Plaster and Stucco
Portland cement-based plaster (stucco) wall cladding and interior finish systems for commercial, institutional, healthcare, education, multifamily, and residential construction. Covers three-coat hard-coat systems (scratch, brown, finish), two-coat systems over rigid substrates, and one-coat fiber-reinforced proprietary systems applied over metal or fiber-cement lath on wood or steel stud framing, over concrete/masonry backup, and at soffits, including basecoat and finish mixes, aggregate, lath and furring selection and attachment, weather-resistive barrier integration, accessories (weep screeds, control and expansion joints, corner and casing beads), mixing, application, and curing.
General Requirements
- Closeout Procedures
administrative and procedural requirements for taking any project (commercial, institutional, industrial, healthcare, education, multi-family) from substantial completion through final completion and contract release - substantial completion inspection and certification, punch list preparation and resolution, final cleaning, record document compilation, attic stock delivery, owner demonstration and training, certificate of occupancy and permit closeout, final payment application, lien waivers, affidavits, and surety consent.
- Construction Progress Documentation
project-wide requirements for documenting construction progress on commercial, institutional, and civil projects, where an Owner, Architect, or Construction Manager requires evidence of schedule compliance and site conditions throughout the construction phase. Covers the construction schedule (baseline CPM or bar-chart, periodic updates, and recovery schedules), photographic and video documentation, periodic progress reporting (daily construction reports, look-ahead schedules, monthly narratives), and survey and layout data submittals.
- Document Confidentiality and AI Use
the administrative framework for the ownership, confidentiality, permitted use, and disposition of the Contract Documents and the project information on any construction contract, read together with every technical standard on the project. States once who owns the drawings, specifications, models, and data files and under what license the Contractor and every lower tier use them, the confidentiality classes of project information and the marking and handling of each, the need-to-know distribution and flow-down of the obligations into every subcontract and purchase order, the terms a hosted document, takeoff, review, or assistant service has to meet before the documents are processed on it, the review and responsibility rules for automated and generated content in the Contractor's deliverables, the consent required before photographs or statements about the project are published, the notice and remediation after a loss or an unauthorized disclosure, and the return or destruction of the documents at closeout, so that the technical standards carry none of it and a supplier or bidder who reads only its own section still sees the obligations.
- Operation and Maintenance Data
preparing, organizing, and delivering operation and maintenance (O&M) data packages for building systems and equipment on commercial, institutional, and industrial projects — directory of documentation, emergency operation manuals, operation manuals, product maintenance manuals, and systems-and-equipment maintenance manuals; covers delivery format (binders, PDF/A, structured data), copy counts, timing relative to Substantial Completion, and training coordination across new construction, renovation, and additions.
- Quality Requirements
project-wide administrative framework for quality assurance and quality control on commercial and institutional new construction, renovation, and addition work — qualification and engagement of independent testing and inspection agencies, pre-construction and in-progress and post-installation testing, field mockups, incorporation of reference standards into contract requirements, quality-related pre-installation meetings, and the chain of responsibility for scheduling, cost, reporting, and corrective action.
- Submittal and Quality Procedures
On any commercial, institutional, healthcare, higher-education, or government project whose project manual requires a formal submittal regime and a contractor quality-control program. Governs the submittal workflow (shop drawings, product data, samples, O&M data, delegated-design documents), the submittal register and schedule, action vs. informational classification, the contractor QC plan, independent testing and inspection agency qualification and reporting, pre-installation meetings, field mock-ups, non-conforming work disposition, and quality documentation at closeout.
- Temporary Facilities and Controls
Specifying all contractor-furnished temporary facilities and site controls installed for the duration of construction and removed before substantial completion — temporary electrical power and lighting, temporary water, temporary heating and ventilation, temporary enclosures, portable sanitary facilities, field offices and staging, construction fencing and hoarding, tree and property protection, site-operation dust and noise control, and removal and restoration. Applies to commercial, institutional, industrial, and multi-family residential projects of any scale and any delivery method.
- Warranties and Bonds
the administrative framework for warranties and surety bonds on any construction contract, read together with every product standard on the project. States once the correction period and its start date, the distinction between the correction period and the warranties, the form, signatories, transferability, and execution of special and extended warranties, the notice, response, correction, and re-warranty procedure for a warranty claim and the Owner's remedies when the Contractor does not respond, the bond types, bond form, penal sums, surety qualification, maintenance bond, subcontractor bonds, and the bond claim procedure, and the content of the warranty book assembled at closeout, so that product standards carry only the warranty type and term unique to their product and lean on this standard for everything else.
Instrumentation & Controls
Process Control Systems
(2)
- Programmable Logic Controllers
Programmable logic controllers (PLCs) and programmable automation controllers (PACs) serving as the real-time logic solver for industrial, process, and water/wastewater (WTP/WWTP) control systems. Covers processor (CPU) selection and memory, the I/O subsystem (discrete and analog input/output modules and signal conditioning), remote and distributed I/O, redundancy and high-availability architectures (hot-standby CPUs, redundant power and network), IEC 61131-3 programming languages, scan-time and performance requirements, power supplies, time synchronization, environmental and hazardous-area ratings, and safety-rated controllers for safety instrumented systems where process safety applies. Applies to controllers mounted in industrial control panels and field enclosures across treatment plants, pump and lift stations, pumping and conveyance systems, and process manufacturing.
- SCADA and HMI Systems
Supervisory control and data acquisition (SCADA) software and operator human-machine interface (HMI) for industrial, process, and water/wastewater (WTP/WWTP) facilities. Covers the supervisory layer that sits above the field controllers: client/server and standalone architectures, redundant (hot-standby) servers with automatic failover, the process data historian and trending, alarm management per ANSI/ISA-18.2, high-performance HMI graphics per ANSI/ISA-101.01 (situational-awareness displays, grayscale background discipline, color reserved for abnormal conditions), reporting, role-based user access and cybersecurity per ISA/IEC 62443, time synchronization, polling and communications to controllers, the software licensing model, and redundant local and remote operator workstations. Applicable to new SCADA platforms and to major migrations or expansions of an existing platform.
Field Instrumentation
(8)
- Analytical Instrumentation
Online, continuous-reading process analyzers that measure the chemistry and quality of a liquid process stream in water treatment, wastewater treatment, and industrial process facilities: pH and ORP, turbidity, free and total chlorine and monochloramine, dissolved oxygen, conductivity, ammonia, nitrate, total organic carbon and UV absorbance, suspended solids and sludge blanket, streaming current, and dissolved ozone. Covers the measurement technology chosen for each parameter, the measuring range, the sensor and the analyzer or transmitter, insertion, submersion, and flow-through installation, sample conditioning, sample lines and sample panels, reagent handling, automatic sensor cleaning, temperature compensation, enclosure and hazardous-location ratings, analog and digital output, calibration and verification against the laboratory reference method, and the method requirements that apply where an analyzer reports under a drinking-water or discharge permit.
- Control Valves and Actuators
The automated final control element of a process control loop — modulating (throttling) control valves and the actuators and positioners that drive them — for industrial, process, and water/wastewater (WTP/WWTP) facilities. Covers globe, segmented-ball, eccentric-plug, and butterfly valves used for modulating control; pneumatic spring-diaphragm and piston actuators and electric actuators sized for continuous modulating duty; analog, HART, and digital/fieldbus valve positioners with diagnostics; and accessories (I/P transducers, solenoid valves, limit switches, position transmitters, volume boosters). Addresses valve sizing and flow-coefficient (Cv) selection per ANSI/ISA-75.01.01 / IEC 60534-2-1, inherent flow characteristic (linear, equal-percentage, quick-open), rangeability, choked flow, cavitation and flashing with anti-cavitation trim selection, predicted noise, fail-safe action (fail-open, fail-closed, fail-last), seat leakage class per ANSI/FCI 70-2, materials and trim, and stroke/calibration. Also covers electric (motorized) actuators on isolation valves (MOVs) where the actuator is the controls interface — open/close or modulate with position feedback to SCADA — because the actuator is I&C scope even when the valve body is an isolation valve.
- Flow Measurement
Flow measurement instrumentation for water/wastewater (WTP/WWTP) and general industrial and process service. Covers the selection, specification, materials, installation, signal output, and calibration of the major closed-pipe and open-channel flow technologies: magnetic (electromagnetic) meters, ultrasonic transit-time and Doppler meters (clamp-on and inline), differential-pressure flow (orifice plate, venturi, and flow nozzle with a paired differential-pressure transmitter), Coriolis mass meters, vortex shedding meters, and open-channel flumes and weirs measured with a secondary level sensor. Addresses application-based technology selection (clean versus dirty or solids-laden fluid, conductivity, accuracy, turndown), straight-run upstream/downstream piping requirements, liner and electrode materials, full-pipe verification, hazardous-area ratings, signal output (4-20 mA/HART, pulse, and digital network), and totalizer and calibration requirements.
- Instrument Installation and Impulse Tubing
The "last-mile" mechanical infrastructure that connects any field process instrument (pressure, differential-pressure, flow, and level) to a live process — primary process connections (taps, root valves, flanged connections at the pipe or vessel), instrument isolation manifolds (2-valve block-and-bleed, 3-valve, and 5-valve DP manifolds), impulse tubing and piping runs from the root valve to the instrument, tube and compression fittings, supports and clamps, condensate and seal pots, purge connections, heat-tracing provisions, and the blowdown/vent/drain valves on those lines. Applies across industrial process facilities, water and wastewater treatment plants, refineries, chemical plants, fossil-fuel power plants, and heavy industrial projects, and is the correct vehicle whenever a project needs an instrument piping/tubing specification separate from both the process piping spec and the instrument-selection spec.
- Level Measurement
Field-mounted level instrumentation for water and wastewater treatment plants (WTP/WWTP), industrial process facilities, and mechanical/plumbing utility service. Covers continuous-level transmitters and point-level switches in tanks, wet wells, clarifiers, sumps, chemical day tanks, bulk storage vessels, and filter beds — including non-contact free-space radar (FMCW and pulse), guided-wave radar (GWR/TDR), ultrasonic, hydrostatic and differential-pressure level, magnetostrictive float, displacer, float-and-cable, capacitance, and vibrating-fork switches. Addresses technology selection by fluid dielectric and vessel geometry, probe and antenna styles, blocking distance, wetted materials and process connections, SIL-rated overfill and high-high functions, signal output (4-20 mA/HART, FOUNDATION Fieldbus, Profibus PA), hazardous-area certification, local indication, calibration, and functional verification. Goes deeper than Process Instrumentation on level-specific technology decisions and installation.
- Pressure Instrumentation
Instrument-tagged pressure, vacuum, and differential pressure measurement points on industrial, process, power, and water and wastewater projects: the pressure transmitter (gauge, absolute, differential, and the pressure side of a multivariable transmitter), its sensing element and isolating diaphragm, its process connection, its output signal, and its housing; diaphragm seals and capillaries; the local pressure gauge with its snubber and siphon; the pressure switch; hazardous-location protection; calibration, installation, and acceptance. Applies to every point that carries a tag in the project instrument index and is read by a process controller or designated for local indication or switching, including pressure points on central plant and plant utility piping that are not building automation points.
- Process Instrumentation
Field-mounted measurement instruments and transmitters for the core process variables pressure, level, and temperature, and for general-purpose process measurement, on industrial, process, and water/wastewater (WTP/WWTP) projects. Covers gauge, absolute, and differential pressure transmitters; hydrostatic, radar (non-contact and guided-wave), ultrasonic, and float level instruments; RTD and thermocouple temperature elements with thermowells and transmitters; signal and output types (4-20 mA with HART, and digital fieldbus options); accuracy and turndown; wetted materials and process connections; ambient and hazardous-area (Class/Division and Zone, intrinsic safety) ratings; local indication; and instrument tagging and loop identification per ANSI/ISA-5.1. Reference loop integration to Control Systems Integration and signal wiring to Instrumentation And Control Cable.
- Temperature Instrumentation
Instrument-tagged temperature measurement points on industrial, process, power, and water and wastewater projects: the sensing element (platinum RTD, thermocouple, or thermistor), its insert and sheath, the thermowell, the connection head, the temperature transmitter and its output signal, thermocouple extension wire, the local dial thermometer, hazardous-location protection, calibration, installation, and acceptance. Applies to every point that carries a tag in the project instrument index and is read by a process controller, including the temperature element of a multivariable transmitter and temperature elements on storage tanks and plant piping that are not building automation points.
Control Panels & Networks
(3)
- Industrial Control Panels
Factory-fabricated industrial control panels and enclosures that house instrumentation and controls (I&C) equipment for industrial, process, and water/wastewater (WTP/WWTP) facilities. Covers UL 508A listed control panels and enclosures housing programmable logic controllers, remote I/O, control relays, power supplies, network switches, and operator interface devices, rated 1000V and below. Addresses enclosure type rating selection (UL/NEMA Type 1, 3R, 4, 4X, 12), short-circuit current rating (SCCR) determination per UL 508A Supplement SB and NEC Article 409, enclosure sizing and component layout, internal power distribution and control power transformers, power-versus-signal wiring segregation, wire and terminal-block identification, thermal management, grounding and bonding, nameplates, and arc-flash labeling.
- Instrumentation and Control Cable
The cable between the field instruments, final control elements, local control stations and motor starters of a plant control system and the control panels, remote I/O and controller cabinets that read and command them, on water, wastewater and industrial process projects: single twisted shielded pair and triad cable for 4 to 20 mA, pulse and RTD circuits; multi-pair and multi-triad homerun cable; thermocouple extension cable; multiconductor cable for the 120 V AC and 24 V DC discrete control and status circuits between panels and field devices; FOUNDATION Fieldbus H1, PROFIBUS PA and RS-485 serial cable; and the cable of intrinsically safe circuits. Covers listing and type (TC, PLTC, ITC, CL2 and CL3), the 300 V and 600 V rating and what each may share a raceway or tray with, conductors, insulation, shields, armor and jacket, pair identification, the shield grounding rule, separation from power circuits, pulling, splices and terminations, wire markers and cable tags, and the continuity, insulation resistance, shield isolation and fieldbus segment tests that put a cable into service. Read with Common Work Results Process.
- Process Control Networks
The operational technology (OT) communications network that connects programmable controllers, remote and distributed I/O, networked field instruments, and the supervisory SCADA and HMI layer in industrial, process, and water and wastewater facilities. Covers the Purdue reference model and the boundary between the OT network and the enterprise network, security zones and conduits under ISA/IEC 62443, industrial Ethernet and serial protocol selection, transmission media by segment class, managed switches and conduit enforcement devices, redundant topologies and recovery time, traffic prioritization, time synchronization, wide-area telemetry to remote sites, the device hardening, account, patch, logging, and backup baseline, and the cable, functional, and security acceptance tests that put the network into service. Applies to new networks, full replacements, and substantial expansions of an existing OT network.
Integration & Commissioning
(1)
- Control Systems Integration and Testing
The integration, configuration, and acceptance-testing scope performed by the control system integrator on an industrial, process, or water and wastewater treatment project, whether the plant is new, expanded, or migrated to a replacement control platform. Covers the division of responsibility between the integrator, the electrical trade, the mechanical and process trade, and the packaged-equipment vendors; the authorship and content of the control narratives; tag and point naming per ANSI/ISA-5.1; the controlled I/O list and the loop diagrams per ANSI/ISA-5.4; the software configuration management workflow from first baseline through as-built; the integration of packaged-skid controls into the plant SCADA; the integrator's secure delivery of the configured system; the integration-seam verification of safety instrumented functions; the factory acceptance test, site acceptance test, site integration test, loop checks, performance verification test, and endurance test under ANSI/ISA-62381 and ANSI/ISA-62382; the commissioning sequence; training on the narratives and the maintenance of the delivered configuration; as-built documentation; the integration warranty; and the turnover of source configuration.
Process
General
(1)
- Common Work Results for Process Equipment
The umbrella standard for process equipment in water treatment plants, wastewater treatment plants, pump stations, and industrial process facilities, read together with every process equipment, process piping, and process valve standard on a project. States once the equipment numbering and nameplate basis, the process equipment data sheet and submittal content, manufacturer qualification and unit responsibility, site and service conditions, equipment supports and anchorage responsibility, vibration and airborne noise acceptance, the motor, drive, and control interface, guards, lubrication and first fills, factory testing and witness policy, manufacturer's field services by visit type, startup, field performance and acceptance testing, training, delivery and storage, warranty, and spare parts and special tools, so the equipment standards inherit these obligations rather than restate them. Carries no product requirements of its own.
Piping
(4)
- Cathodic Protection
Galvanic and impressed-current cathodic protection of buried and submerged metallic structures inside the fence of a water treatment plant, a wastewater treatment plant, a pump station, or an industrial process facility, read together with Common Work Results Process: buried ductile iron and steel yard piping with its valves and fittings, the interior submerged surfaces and the bottom exterior of steel water storage tanks, steel well casings, and the buried steel structures and sheet pile the drawings assign to the system. Covers the corrosivity survey, the design responsibility, the criteria of protection, galvanic anodes and their backfill, rectifiers, impressed-current anodes and anode beds, test stations, permanent reference electrodes and coupons, the joint bonds that make a gasketed line one conductor, electrical isolation and its test, the decoupling device between a protected structure and the grounding electrode system, interference and stray current mitigation, commissioning from the native survey through the final potential survey, the commissioning report, and the surveys that follow.
- Ductile Iron Process Piping
Ductile iron pipe, fittings, joints, linings, and exterior coatings for the process piping of water treatment plants, wastewater treatment plants, pump stations, and industrial process facilities, inside the plant fence: piping exposed in galleries, buildings, vaults, and wet wells, piping submerged in tanks and channels, and buried yard piping between plant structures. Covers pipe per AWWA C151 by pressure class or special thickness class, flanged pipe per AWWA C115, full-body fittings per AWWA C110 and compact fittings per AWWA C153, flanged, push-on, mechanical, restrained, and grooved joints per AWWA C606, thrust restraint, flange gaskets and bolting by service and exposure, interior lining selected per service, exterior coating by exposure including polyethylene encasement per AWWA C105, outlets and taps, dismantling joints and sleeve couplings, wall pipes through water-retaining walls, the hydrostatic and leakage test per AWWA C600, and disinfection of finished-water lines per AWWA C651.
- Plastic Process Piping
Thermoplastic and fiberglass-reinforced plastic process and chemical piping inside the fence of a water, wastewater, or industrial treatment plant: PVC, CPVC, polyethylene, PVDF, polypropylene, and FRP pipe, fittings, flanges, and joints for process water, chemical feed, sludge, reclaimed and non-potable water, drain, and plant potable water service, exposed in galleries, chemical rooms, and buildings and buried as yard piping between plant structures. Covers material selection by chemical and temperature, solvent-cement, heat-fusion, adhesive-bonded, flanged, threaded, and gasketed joints, transitions to metallic piping, double-containment piping with leak detection, support and thermal-expansion provisions particular to plastics, ultraviolet and freeze protection, buried embedment, thrust restraint and tracer wire, the hydrostatic test that proves the installed piping, and AWWA C651 disinfection of plant potable lines.
- Steel and Stainless Steel Process Piping
Carbon steel and stainless steel process piping inside the fence of a water, wastewater, or industrial process plant and its pump stations: raw, settled, finished, service, and plant water; blower discharge, aeration, and channel air headers; sludge, scum, and digested solids; and the chemical services that steel or stainless steel can carry. Covers the pipe and the fabricated steel pipe of AWWA C200, the stainless alloy and wall selection, fittings and flanges, welded, threaded, grooved, flanged, and coupled joints, dismantling joints and flanged coupling adapters, wall pipes and penetrations, linings and shop coatings, pickling and passivation of stainless welds, the temperature-driven provisions of hot air headers, installation exposed in galleries, buildings, and vaults and buried as yard piping between plant structures, the pressure, leakage, and weld examination that prove the assembly, and the disinfection of finished-water lines.
Valves
(7)
- Air Release and Vacuum Valves
Air release valves, air/vacuum valves, and combination air valves under AWWA C512 for water, wastewater, reclaimed water, and sludge pipelines in water and wastewater treatment plants, pump stations, and industrial process plants, installed exposed at the high points of gallery and building piping and in vaults on buried yard piping, together with the valve on a site water main or sewage force main where the drawings designate it to be furnished under this standard. Read with Common Work Results Process, which carries the submittal register, the factory and witnessed test policy, manufacturer's field services, nameplates, spare parts basis, anchorage, and the other provisions every process valve inherits. Covers the three valve types and the wastewater pattern with its backflushing accessories, the pressure class, the sizing of the large orifice from the filling and draining rates and of the small orifice from the working pressure, body, float, seat, and trim materials, inlet and outlet connections, slow-closing and surge-check devices, the isolation valve beneath each air valve, AWWA C550 coating, shop and field tests, and installation exposed, in vaults, with the vent to atmosphere, and with freeze protection.
- Butterfly Valves
Rubber-seated butterfly valves for isolation and non-modulating throttling in water, wastewater, reclaimed water, and industrial process piping, exposed in plants, galleries, and vaults or buried in yard piping, 3 in. through 72 in. under AWWA C504 and 78 in. and larger under AWWA C516, with MSS SP-67 and API 609 valves where the size or the service falls outside the AWWA standards. Covers the valve body and end connections, pressure class, seat, disc, seating surfaces, shaft, bearings and shaft seals, the manual operator, the mounting interface and torque data a power actuator is sized from, buried-service provisions including the valve box and extension stem, AWWA C550 coatings, proof-of-design and production testing, installation, and field testing.
- Eccentric Plug Valves
Resilient-seated eccentric plug valves under AWWA C517, 3 in. through 72 in., used for isolation and fixed-position throttling of raw water, wastewater, sludge, scum, grit, and other solids-bearing liquids in water and wastewater treatment plants, pump and lift stations, and industrial process plants, installed exposed in galleries and valve vaults or buried on site force mains. Covers the body, plug, seat, shaft, bearings and seals, port area, pressure rating and shutoff direction, end connections and bolting, the AWWA C550 lining and coating, the manual operator (lever, worm gear, handwheel, chainwheel, and the 2 in. operating nut), the mounting interface and torque data for a power actuator, buried-service provisions including the extension stem and valve box, shop testing, installation orientation for solids service, field testing, warranty, and spare parts.
- Knife Gate Valves
Knife gate valves under MSS SP-81 and AWWA C520, 2 in. through 96 in., for isolation of sludge, scum, grit, screenings, dewatered cake, slurry, and other solids-bearing or dry-solids service in water treatment plants, wastewater treatment plants, pump stations, and industrial process facilities, in pipelines and on the chutes, hoppers, and bin outlets of screening, grit, thickening, and dewatering equipment, exposed in galleries, buildings, and vaults or, where the drawings designate it, buried, read together with Common Work Results Process. Covers the bonnetless and the bonneted valve, the resilient perimeter seat and the metal seat, unidirectional and bidirectional shutoff, the standard, full round, square, and rectangular port, the wafer, lugged, and flanged body with its flange drilling and pressure rating, the body, gate, stem, yoke, and bolting materials, the beveled gate, the seat and seal elastomers, the packing and gland, the chest flush ports, deflection cone, splash guard, liner, and gate scraper of slurry and dry solids service, the rising stem, stem protector, position indicator, and lockout, the manual operator furnished with the valve, the mounting interface and thrust data a power actuator is sized from, AWWA C550 coating on ferrous bodies, the valve box and extension stem of a buried valve, proof-of-design and production tests, installation orientation, and field testing.
- Process Check Valves
Check valves individually specified on the pump discharges and process piping of water treatment plants, wastewater treatment plants, pump stations, and industrial process facilities, in raw, settled, finished, reclaimed, and plant water, wastewater, sludge, scum, grit, and industrial process service, exposed in galleries, buildings, and vaults or buried in yard piping. Covers swing check valves under AWWA C508 with their lever and weight, lever and spring, air cushion, and oil dashpot closure provisions; resilient-hinge rubber flapper check valves; tilting-disc check valves; ball check valves for sludge and grit; silent spring-loaded center-guided check valves under MSS SP-125 and nozzle check valves; dual-disc wafer check valves under AWWA C518 and API 594; foot valves for suction-lift pumps; rubber duckbill check valves at outfalls and overflows; the closure response the Engineer of Record's surge analysis requires of each pump discharge valve and the types that deliver it; body, disc, seat, and hinge materials; pressure rating and end connections; position indication and limit switches; the backflow actuator; AWWA C550 coatings; vault and buried installation; shop testing; installation orientation; and the field closure test on each pump.
- Resilient-Seated Gate Valves
Gate valves furnished for isolation of water, wastewater, reclaimed water, and industrial process lines inside the fence of a water treatment plant, a wastewater treatment plant, a pump station, or an industrial process facility, exposed in galleries, buildings, and vaults or buried in yard piping, read together with Common Work Results Process. Covers the resilient-seated valve under AWWA C509 and AWWA C515, the metal-seated double-disc valve under AWWA C500 where a metal seat is still specified, and the cast iron gate valve under MSS SP-70 for process lines outside the AWWA standards; the body, bonnet, and bolting, the encapsulated wedge and its elastomer, the stem, stem nut, and stem seals, non-rising and outside screw and yoke stems, end connections and flange drilling, the rated working pressure, the direction of opening, the manual operator furnished with the valve, gear operators and bypass valves on large sizes, tapping valves and tapping sleeves as a conditional article, the mounting interface and thrust data a power actuator is sized from, the valve box and extension stem of a buried valve, AWWA C550 coating, proof-of-design and production tests, installation orientation, and field testing. A gate valve on a site water main outside the plant fence is furnished under Water Distribution Piping or Site Utilities unless the drawings designate this standard for it.
- Valve and Gate Actuators
Power actuators and separately furnished manual operators for isolation valves and slide gates in water, wastewater, reclaimed water, and industrial process plants and their pump stations, read with Common Work Results Process. Covers electric motor actuators under AWWA C542, multi-turn and quarter-turn, for open-close, inching, and modulating-capable duty under supervisory control, with their integral reversing starters, local controls, torque and position sensing, open, closed, and position signals, and the hardwired or network interface to the plant control system; pneumatic and hydraulic cylinder and vane actuators under AWWA C541 with their solenoid valves, limit switches, speed controls, fail-safe means, and the air or hydraulic supply connection; and the floor stands, bench stands, extension stems, stem guides, bevel gear boxes, universal joints, and chainwheels that operate an exposed valve or a gate from an operating floor above it. Addresses actuator selection and duty, torque and thrust sizing from the valve or gate manufacturer's data, the enclosure and submergence rating, the mounting interface and the party that mounts the actuator, factory and field tests, and the record of limit and torque settings.
Gates
(1)
- Slide Gates and Stop Logs
Slide gates, weir gates, flap gates, and stop logs on the walls and in the channels of water, wastewater, reclaimed water, and industrial process structures, including fabricated stainless steel slide gates under AWWA C561, fabricated aluminum under AWWA C562, fabricated composite under AWWA C563, cast iron under AWWA C560, open-channel fabricated-metal slide and weir gates under AWWA C513, cast iron and fabricated flap gates at outfalls and backflow points, and aluminum, fiberglass, and stainless steel stop logs with their guides, lifting devices, and storage racks. Covers the gate schedule interface, the seating and unseating design heads and the leakage allowance, the frame, slide, guides, seats, and seals, the invert configuration, the stem, stem guides, stem cover, and the manual lift on a self-contained gate, the thrust and the mounting interface a power actuator or floor stand is furnished to, the wall thimble, the anchor bolts, the tolerance the concrete must meet, finishes, shop assembly and tests, installation, and the field leakage and operation tests.
Pumps
(4)
- Horizontal Centrifugal Process Pumps
Horizontal rotodynamic pumps for clean and raw water, finished water, service and seal water, plant washwater, and clean process transfer in water treatment plants, wastewater treatment plants, pump stations, and industrial process facilities, read together with Common Work Results Process. Covers end-suction frame-mounted pumps, including ASME B73.1 chemical process pumps, end-suction close-coupled pumps, axially split-case double-suction pumps, and self-priming centrifugal pumps for clean liquids. Addresses the hydraulic selection against the pump schedule, the operating region, NPSH margin and suction energy, the casing, impeller, wear rings, shaft, and bearings, packed and mechanical shaft sealing with the flush plan, the baseplate, coupling and guard, the motor interface, shop coating, the factory hydrostatic, performance, and NPSH tests under ANSI/HI 14.6, installation, alignment, field testing, the seal warranty, and spare parts.
- Positive Displacement Pumps
Positive displacement pumps for the sludge, scum, grit slurry, thickened and dewatered solids, water treatment residuals, septage, grease, and polymer solution services of water treatment plants, wastewater treatment plants, and industrial process facilities, read with Common Work Results Process: progressive cavity, rotary lobe, plunger and piston, peristaltic hose, and air-operated double-diaphragm pumps. Covers the pump end and its wetted materials, the stator and rotor, the lobes and wear plates, the plungers and ball checks, the hose and its lubricant, the diaphragms and air valve, shaft sealing, dry-run protection, the gear reducer, coupling, belt, and speed control that drive the pump, the motor features the pump requires, the discharge relief device and high-pressure shutdown every positive displacement pump requires, the suction and discharge connections, flushing and cleanout provisions, the cake feed hopper where the pump is fed dewatered solids, the baseplate, the factory performance test under ANSI/HI 3.6, 6.6, or 10.6, field testing, shop coating, storage of elastomer parts, warranty of wear parts, and spare parts.
- Submersible Solids-Handling Pumps
Individually specified solids-handling wastewater pumps in water and wastewater treatment plants, plant influent pump stations built in a water-retaining structure, and large collection-system pump stations, read together with Common Work Results Process, which carries the submittal register, the factory and witnessed test policy, manufacturer's field services, nameplates, spare parts basis, anchorage, and vibration and noise acceptance for every process equipment standard. Covers the pump in every arrangement the service uses: submersible in a wet well on guide rails with a discharge elbow, dry-pit submersible with an immersible motor, horizontal and vertical dry-pit solids-handling pumps with a conventional motor, and self-priming solids-handling pumps at grade, for raw sewage, primary and secondary effluent, return and waste activated sludge, plant drain, and stormwater and combined flow inside a plant. Addresses the hydraulic selection against the pump schedule, spherical solids passage, non-clog channel, vortex, screw-centrifugal, and chopper impellers, the wetted materials for grit and corrosive service, wear rings and their adjustment, tandem mechanical seals and seal leak detection, the submersible motor with its cooling, sensors, cable, and hazardous-location listing, the guide rail system, discharge elbow, and lifting chain, dry-pit and self-priming mounting, speed control interface, factory performance testing under ANSI/HI 11.6 or ANSI/HI 14.6, the field drawdown test, shop coating, warranty, and spare parts.
- Vertical Turbine Pumps
Line-shaft vertical turbine pumps and submersible well pumps that lift raw water from an intake, a wet well, or a well, pump finished water from a clearwell to high service, or boost a pressurized line from a can or barrel, in water treatment plants, raw water intakes, well fields, booster stations, and industrial process plants, read with Common Work Results Process. Covers the four arrangements, wet-pit line-shaft turbine, can or barrel-mounted line-shaft turbine, deep-well line-shaft turbine, and submersible well pump with a submersible motor; the bowl assembly with its stages, impellers, bearings, wear rings, and strainer; the column, line shaft, shaft bearings, and the open or enclosed lubrication that decides them; the discharge head, its stuffing box or mechanical seal, and pre-lubrication; the suction can; the submersible motor, its cable, splice, and column check valve; the vertical hollow-shaft or solid-shaft motor features and the critical speed and reed frequency checks; the manufacturer's review of the intake against ANSI/HI 9.8; the factory performance, NPSH, and hydrostatic tests; field testing; the shop coating; and spare parts.
Storage
(1)
- Water Storage Tanks
Water storage tanks furnished as a product for a water treatment plant, a pump station, a well field, or a distribution system, holding raw, settled, finished, reclaimed, or plant utility water, read with Common Work Results Process: the welded carbon steel ground storage reservoir, standpipe, and elevated tank under AWWA D100, the composite elevated tank with a concrete pedestal under AWWA D107, the factory-coated bolted steel tank under AWWA D103, the wire- and strand-wound circular prestressed concrete tank under AWWA D110, and the tendon-prestressed concrete tank under AWWA D115. Covers the construction type, the roof, the structural design basis and the delegated design of the shell, roof, and anchorage, the foundation as a design interface, the inlet, outlet, overflow, drain, manways, hatches, vents, ladders, fall protection, mixing, level indication, and the fittings that serve cathodic protection and instruments, the inside and outside coating systems under AWWA D102 with their preparation, holdback, thickness, holiday testing, and drinking water certification, the bolted tank factory coating and its repair, the prestressed tank cover coat and roof treatment, weld inspection, the hydrostatic test and its leakage criterion, disinfection under AWWA C652 with bacteriological clearance, delivery, warranty with the first-anniversary inspection, and spare parts. A fire protection water tank built to AWWA D100 is specified here where the drawings assign it.